Search results for "Meter"
showing 10 items of 16915 documents
Steam sterilization processes affect the stability of clinical thermometers: Thermistor and prototypal FBG probe comparison
2020
Abstract Temperature is one of the most frequently measured physical quantities in clinical environment and a good biomarker of illness. The need for reusable probes, which have to be sterilized to prevent infections, requires the metrological qualification of thermometer probes in response to ageing effects induced by several sterilization processes. In this study, we investigated the effect of repeated sterilizations on both a commonly-used autoclavable thermistor probe and a prototypal Fiber Bragg Gratings (FBG) probe for temperature measurements. Findings highlighted a greater reliability of the proposed FBG probe than the commercial thermistor. Specifically, the FBG probe was able to w…
Gaia -ESO Survey: Analysis of pre-main sequence stellar spectra
2015
This paper describes the analysis of UVES and GIRAFFE spectra acquired by the Gaia-ESO Public Spectroscopic Survey in the fields of young clusters whose population includes pre-main sequence (PMS) stars. Both methods that have been extensively used in the past and new ones developed in the contest of the Gaia-ESO survey enterprise are available and used. The internal precision of these quantities is estimated by inter-comparing the results obtained by such different methods, while the accuracy is estimated by comparison with independent external data, like effective temperature and surface gravity derived from angular diameter measurements, on a sample of benchmarks stars. Specific strategi…
Comparison of in Situ Land Surface Temperatures Measured with Radiometers and Pyrgeometers: Consequences for Calibration and Validation of Thermal In…
2018
Land surface temperature (LST) is a key magnitude in many exchange processes between the surface and the atmosphere. LST measurement from satellites provides an efficient way to monitor its change across wide areas on Earth, an essential issue being LST validation using in situ measurements to assess its accuracy and precision. Presently, there are two widely used methodologies: temperature measurements made by wideband radiometers observing the land surface with a given viewing angle and a limited field of view, and measurements provided by total radiation pyrgeometers with a nearly hemispheric field of view. Although both measurements are correlated, they are not equivalent; thus, it is r…
Multi-mycotoxin analysis in wheat semolina using an acetonitrile-based extraction procedure and gas chromatography–tandem mass spectrometry
2012
A new analytical method for the rapid and simultaneous determination of ten mycotoxins including patulin, zearalenone and eight trichothecenes (nivalenol, fusarenon-X, diacetoxyscirpenol, 3-acetyl-deoxynivalenol, neosolaniol, deoxynivalenol, T-2 and HT-2) in wheat semolina has been developed and optimized. Sample extraction and purification were performed with a modified QuEChERS-based (acronym of Quick, Easy, Cheap, Effective, Rugged and Safe) procedure and determined by gas chromatography (GC) coupled to triple quadrupole instrument (QqQ). This is the first paper on the application of GC-QqQ-MS/MS to analysis of mycotoxins. Careful optimization of the gas chromatography-tandem mass spectr…
Impact of viewing distance on relative depth judgements for stimuli in physical space
2019
In natural viewing, numerous depth cues are available to the visual system, but their significance varies considerably depending on the viewing distance. How is it reflected in the outcome of depth judgements? We have designed a psychophysical experiment with a limited number of depth cues to examine distance-related changes in the correct response rate and time. Twenty young adults evaluated relative depth of stimuli in physical space. Each time four constant angular size achromatic stimuli were presented on a volumetric multi-planar display. One of these stimuli was demonstrated closer to the observer comparing to others. The experiment followed the four-interval forced-choice procedure. …
Magnetic properties of Co2Mn1−xFexSi Heusler alloys
2006
Co2Mn1−xFexSi Heusler alloys with Fe concentration x = 0–0.4 as prepared by arc melting show a L21 long range order for all Fe concentrations. Magnetic properties of Co2Mn1−xFexSi Heusler alloys were investigated by magnetometry and circular magnetic dichroism. The magnetization of the Fe doped Heusler alloys is in agreement with the Slater–Pauling values expected for half-metallic ferromagnets. Element specific magnetic moments as determined by x-ray absorption using the total electron yield method are in disagreement with theoretical predictions for x = 0 but approach the predicted values as the Fe concentration increases. Surprisingly small Fe concentration increases the magnetic moments…
Synthesis and solution properties of star-shaped poly(tert-butyl acrylate)
2000
A series of star polymers consisting of poly(tert-butyl acrylate) arms and an ethyleneglycol dimethacrylate (EGDMA) microgel core were synthesized using anionic polymerization. The effect of various parameters (precursor length, ratio [[EGDMA]/[Initiator], reaction time, and overall concentrations) on the average number of arms was investigated. Molecular weights were determined using GPC coupled with an online viscometer and MALLS. The exponents for the relation between intrinsic viscosity or radius of gyration and molecular weight, respectively, are extremely low, indicating that the dimensions of the star polymers only slightly increase with the number of arms. After a certain number of …
An experimental method for the determination of the photon flow reflected and absorbed by aqueous dispersions containing polycrystalline solids in he…
1991
An experimental method for the evaluation of the photon flow reflected and absorbed by aqueous dispersions containing polycrystalline solids is proposed. The method is based on actinometric measurements. It is shown that the values obtained are independent of the particle sizes and of the concentration of the solids at least in the experimental conditions and in the range used in the present study (particle size range: 40–500 μm; solids concentration: 0.1–2 g liter−1). The results suggest that the values obtained should be attributed to the interfaces formed between the surface of the solids and the medium. The method is applied to a photocatalytic reaction, namely to the photodegradation o…
A new sample of large angular size radio galaxies
2004
We present in this paper a detailed study of a new sample of large angular size FR I and FR II radio galaxies and compare the properties of the two classes. As expected, a pure morphology based distinction of FR Is and FR IIs corresponds to a break in total radio power. The radio cores in FR Is are also weaker than in FR IIs, although there is not a well defined break power. We find that asymmetry in the structure of the sample members must be the consequence of anisotropies in the medium where the lobes expand, with orientation playing a minor role. Moreover, literature data and our observations at kiloparsec scales suggest that the large differences between the structures of FR I and FR I…
Hydrolysis and chemical speciation of dioxouranium(VI) ion in aqueous media simulating the major ion composition of seawater
2004
Abstract The hydrolysis and chemical speciation of the dioxouranium(VI) ion at 25 °C was studied in a number of binary electrolytes (LiCl, NaCl, MgCl2, CaCl2, Na2SO4) and some mixtures (NaCl–Na2SO4, NaNO3–Na2SO4, CaCl2–MgCl2) as well as artificial seawater (SSWE) as a function of ionic strength. The results in LiCl, CaCl2 and MgCl2 solutions confirmed the formation of (UO2)2(OH)22+, (UO2)3(OH)42+, (UO2)3(OH)5+ and (UO2)3(OH)7− species (at I=0 mol l−1: log Tβ22=−5.76, log Tβ34=−11.82, log Tβ35=−15.89 and log Tβ37=−29.26). For NaNO3, NaCl and artificial seawater the hydrolysis constant for the formation of the UO2(OH)+ species was also determined (at I=0 mol l−1: log Tβ11=−5.19). The results …