Search results for "Microchemistry"
showing 9 items of 9 documents
Scanning electron microscopic and X ray microanalysis study of the mineral deposits in pseudoxanthoma elasticum.
1977
A skin biopsy of a 37 year old man with typical lesions of pseudoxanthoma clasticum (P.E.) associated with angioid streaks (Groenblad-Strandberg Syndrom) was examined with a scanning E. M. (SEM) and a SEM provided with a X ray micro-analyser. The SEM provided with X ray microanalyser enabled us to see the correspondence between the crystalline deposits and a calcium salt. The potassium, sodium and magnesium analysis of the specimen permits us to verify that the P.E. dermis is rich in K and poor in Mg.
Current trends in solid-phase-based extraction techniques for the determination of pesticides in food and environment
2006
Solid-phase extraction (SPE) procedures for pesticide residues in food and environment are reviewed and discussed. The use of these procedures, which include several approaches such as: matrix solid-phase dispersion (MSPD), solid-phase micro-extraction (SPME) and stir-bar sorptive extraction (SBSE), represents an opportunity to reduce analysis time, solvent consumption, and overall cost. SPE techniques differ from solvent extraction depending on the interactions between a sorbent and the pesticide. This interaction may be specific for a particular pesticide, as in the interaction with an immunosorbent, or non-specific, as in the way a number of different pesticides are adsorbed on apolar or…
Neoproterozoic Rosetta Gabbro from northernmost Arabian–Nubian Shield, south Jordan : Geochemistry and petrogenesis
2017
An Ediacaran mafic intrusion of south Jordan is a distinctive appinitic igneous rock with a possibly unique texture, characterized by spherical clots up to 40 mm in diameter composed of amphibole cores from which plagioclase euhedra radiate; we call it the Rosetta Gabbro. It is exposed as a small (ca. 750 m(2)) outcrop in the Neoproterozoic basement of south Jordan. A second outcrop of otherwise similar gabbro is located about 400 m to the north of the Rosetta Gabbro, but it lacks the distinctive texture. The Rosetta Gabbro could represent a magma pipe. It intrudes the Aqaba Complex (similar to 600 Ma) granitoids and metasediments of the Janub Metamorphic Complex (633-617 Ma). The gabbro is…
X-ray analysis on the nanogram to microgram scale using porous complexes
2012
X-ray single-crystal diffraction (SCD) analysis has the intrinsic limitation that the target molecules must be obtained as single crystals. Here we report a protocol for SCD analysis that does not require the crystallization of the sample. In our method, tiny crystals of porous complexes are soaked in a solution of the target, such that the complexes can absorb the target molecules. Crystallographic analysis clearly determines the absorbed guest structures along with the host frameworks. Because the SCD analysis is carried out on only one tiny crystal of the complex, the required sample mass is of the nanogram–microgram order. We demonstrate that as little as about 80 nanograms of a sample …
Matrix solid-phase dispersion extraction procedure for multiresidue pesticide analysis in oranges.
1996
A multiresidue extraction method based on matrix solid-phase dispersion (MSPD) is optimized for the extraction and gas chromatographic screening of eighteen insecticides (aldrin, carbophenothion, captafol, chlorpyriphos, chlorfenvinphos, diazinon, dicofol, alpha-endosulfan, beta-endosulfan, ethion, fenitrothion, folpet, methidathion, malathion, methyl-azinphos, methyl-parathion, phosmet, and tetradifon) from oranges. After optimization of different parameters, such as type of solid phase used and the amount of solid phase or eluent, recoveries ranged from 67 to 102% with relative standard deviations ranging from 2 to 10%. The limits of detection, calculated as 3 times the baseline noise ran…
Application of solid-phase microextraction combined with derivatization to the determination of amphetamines by liquid chromatography
2004
This work evaluates the utility of solid-phase microextraction (SPME) in the analysis of amphetamines by liquid chromatography (LC) after chemical derivatization of the analytes. Two approaches have been tested and compared, SPME followed by on-fiber derivatization of the extracted amphetamines, and solution derivatization followed by SPME of the derivatives formed. Both methods have been applied to measure amphetamine (AP), methamphetamine (MA), and 3,4-methylenedioxymethamphetamine (MDMA), using the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) and carbowax-templated resin (CW-TR)-coated fibers. Data on the application of the proposed methods for the analysis of different kin…
A Microassay for Measuring Glycogen in 96-Well-Cultured Cells
1996
Abstract This study describes a rapid, sensitive, and automated spectrophotometric enzymatic microassay that measures the intracellular glycogen of primary cultured hepatocytes and other cultured cells in 96-well plates and can be adapted for other samples that are transferred to these plates. The procedure involves in situ disruption of cells, followed by hydrolysis of glycogen into glucosyl units by fungal glucoamylase (exo-1,4-α- D -glucosidase, EC 3.2.1.3), and glucose determination with the glucose oxidase colorimetric method. The color intensity can be measured in conventional ELISA readers, and the data can be fed to an on-line computer for rapid processing. The advantages of this me…
High Pressure Liquid Chromatographic Analysis of Barbiturates in the Picomole Range by Fluorometry of Their DANS-Derivatives
1974
Revisited BIA-MS combination: Entire "on-a-chip" processing leading to the proteins identification at low femtomole to sub-femtomole levels
2008
International audience; We present the results of a study in which biomolecular interaction analysis (BIA, Biacore 2000) was combined with mass spectrometry (MS) using entire "on-a-chip" procedure. Most BIA-MS studies included an elution step of the analyte prior MS analysis. Here, we report a low-cost approach combining Biacore analysis with homemade chips and MS in situ identification onto the chips without elution step. First experiments have been made with rat serum albumin to determine the sensitivity and validation of the concept has been obtained with an antibody/antigen couple. Our "on-a-chip" procedure allowed complete analysis by MS-MS of the biochip leading to protein identificat…