Search results for "Microprobe"

showing 7 items of 57 documents

Investigation of phthalocyanine crystals exposed to NO2 ambient gas

2002

Crystals of free base phthalocyanine (H2pc) and its unsubstituted metal derivatives Mpc (where M=Ni, Cu, Zn, Pb, and pc=C32H16N8 2−=phthalocyanine ligand) were examined after being exposed to NO2 ambient gas. Scanning electron microscopy (SEM) supported by X-ray microprobe analysis (EDAX), UV–Vis and FTIR spectroscopy as well as X-ray powder diffractometry (XRD) were applied to study the crystals chemistry and surface morphology. The NO2 molecules were found to penetrate the crystal unit which led to the breakdown of the phthalocyanine macrocycle. The surface of the doped crystals has been scaled and covered by a layer composed predominantly of phthalimide. Despite vacuum desorption, it has…

X-ray powder diffractometryMicroprobeScanning electron microscopePhthalocyaninesAnalytical chemistryInorganic ChemistryMetalCrystalchemistry.chemical_compoundAdsorptionchemistryvisual_artDesorptionMaterials Chemistryvisual_art.visual_art_mediumPhthalocyanineUV–Vis and FTIR spectroscopyPhysical and Theoretical ChemistryFourier transform infrared spectroscopyScanning electron microscopyX-ray microprobeNitrogen dioxidePolyhedron
researchProduct

FIB-FESEM and EMPA results on Antoninianus silver coins for manufacturing and corrosion processes

2018

[EN] A set of ancient Antoninianus silver coins, dating back between 249 and 274¿A.D. and minted in Rome, Galliae, Orient and Ticinum, have been characterized. We use, for the first time, a combination of nano-invasive (focused ion beam-field emission scanning electron microscopy-X-ray microanalysis (FIB-FESEM-EDX), voltammetry of microparticles (VIMP)) and destructive techniques (scanning electron microscopy (SEM-EDX) and electron microprobe analysis (EMPA)) along with non-invasive, i.e., micro-Raman spectroscopy. The results revealed that, contrary to the extended belief, a complex Ag-Cu-Pb-Sn alloy was used. The use of alloys was common in the flourishing years of the Roman Empire. In th…

archaeometry EMPA FIB-FESEM-EDX ancient coinsMaterials scienceScanning electron microscopeScienceAlloy02 engineering and technologyElectron microprobeengineering.material01 natural sciencesMicroanalysisArticleCorrosionEMPAchemistry.chemical_compoundMultidisciplinary010401 analytical chemistryMetallurgyFIB-FESEM-EDXQRSilvering021001 nanoscience & nanotechnologyancient coins0104 chemical sciencesAmalgam (dentistry)chemistryPINTURAengineeringMedicinearchaeometry0210 nano-technologyEMPA
researchProduct

Controlling the spatial distribution of aluminum in ZSM-5 crystals

1993

Abstract The spatial distribution of aluminum over ZSM-5 crystals was systematically studied using electron microprobing on polished crystals. Crystals synthesized with TPABr as template exhibit a pronounced enrichment of aluminum in the crystal rim, essentially irrespective of the aluminum source employed, although aluminum sources with organic anions are favoring less inhomogeneous profiles. With 1,6-hexanediol or from totally inorganic reaction gels, crystals with completely homogeneous aluminum profiles are obtained, even if the crystals grow larger than 50 μm. In the 1,6-hexanediol system the homogeneous profiles could be changed to profiles similar to the TPABr system by addition of K…

biologyInorganic chemistryGeneral Engineeringchemistry.chemical_elementGeneral ChemistryElectronElectron microprobeSilicateIonCrystalchemistry.chemical_compoundchemistryAluminiumbiology.proteinGeneral Materials ScienceZSM-5Organic anionMicroporous Materials
researchProduct

Development of a Matrix-Matched Sphalerite Reference Material (MUL-ZnS-1) for Calibration of In Situ Trace Element Measurements by Laser Ablation-Ind…

2016

Sphalerite (ZnS) is an abundant ore mineral and an important carrier of elements such as Ge, Ga and In used in high-technology applications. In situ measurements of trace elements in natural sphalerite samples using LA-ICP-MS are hampered by a lack of homogenous matrix-matched sulfide reference materials available for calibration. The preparation of the MUL-ZnS1 calibration material containing the trace elements V, Cr, Mn, Co, Ni, Cu, Ga, Ge, As, Se, Mo, Ag, Cd, In, Sn, Sb, Tl and Pb besides Zn, Fe and S is reported. Commercially available ZnS, FeS, CdS products were used as the major components, whereas the trace elements were added by doping with single-element ICP-MS standard solutions a…

chemistry.chemical_classificationArgonLaser ablationMaterials scienceSulfide010401 analytical chemistryAnalytical chemistryTrace elementchemistry.chemical_elementGeologyElectron microprobeengineering.material010502 geochemistry & geophysics01 natural sciences0104 chemical sciencesSphaleritechemistryGeochemistry and PetrologyengineeringInductively coupled plasma mass spectrometryPowder mixture0105 earth and related environmental sciencesGeostandards and Geoanalytical Research
researchProduct

Synthesis of a quenchable high-pressure form of magnetite (h-Fe3O4) with composition Fe1(Fe2+0.75Mg0.26)Fe2(Fe3+0.70Cr0.15Al0.11Si0.04)2O4

2014

We report the synthesis of h-magnetite, ideally h-Fe 3 O 4 with considerable amounts of substitutional cations (Cr, Mg, Al, Si) and quenchable to ambient conditions. Two types of experiments were performed at 18 GPa and 1800 °C in a multi-anvil press. In one, we used an oxide mixture with a majoritic stoichiometry Mg 1.8 Fe 1.2 (Al 1.4 Cr 0.2 Si 0.2 Mg 0.2 )Si 3 O 12 , with Si and Mg in excess as starting material (MA-367, MA-380). In the second type of experiment (MA-376), we started from an oxide mixture on the composition of the Fe-oxide phase obtained in MA-367. The Fe-oxide phases of both experiments were investigated by electron microprobe and transmission electron microscopy includin…

chemistry.chemical_compoundCrystallographyGeophysicsElectron diffractionGeochemistry and PetrologyChemistryElectron energy loss spectroscopyFormula unitPhase (matter)OxideElectron microprobeWadsleyiteStishoviteAmerican Mineralogist
researchProduct

Effect of Hot Dip Galvanized Steel Surface Chemistry and Morphology on Titanium Hexafluoride Pretreatment

2017

Titanium hexafluoride pretreatments are known to improve paint adhesion and function as a barrier between the coating and the hot dip galvanized (HDG) steel surface. Interactions at the zinc/pretreatment interface are of utmost importance for the formation of pretreatment layers and the corrosion resistance of color coated hot dip galvanized steels. Removal rate of inert aluminum oxide from HDG steel samples by chemical dissolution was studied. XPS measurements showed that the surface Al2O3 layer thickness decreased rapidly already at mild alkaline cleaning, while complete removal of Al required severe etching. Low reactivity of an Al2O3-rich surface was confirmed by impaired formation of a…

pretreatment surface morphologyMaterials sciencechemistry.chemical_elementalumiinioksidi02 engineering and technologyElectron microprobe01 natural sciencesCorrosionaluminum oxidechemistry.chemical_compoundsymbols.namesakeHexafluorideX-ray photoelectron spectroscopy0103 physical sciencessurface morphology010302 applied physicsta114Precipitation (chemistry)Metallurgytechnology industry and agricultureGeneral Engineeringpretreatment021001 nanoscience & nanotechnologyGalvanizationhot dip galvanized steelchemistryhelium ion microscopysymbolsGrain boundary0210 nano-technologyTitaniumAdvances in Materials Physics and Chemistry
researchProduct

The Ti-influence on the tourmaline color

2008

Titanium was examined in different black tourmalines by spectrophotometric analyses in the region between 12500 and 27000 cm-1 (800-370 nm) using a microscope spectrophotometer MPV-5P, Leitz (Germany), and chemically analyzed on an electron microprobe Camebax Microbeam, Cameca (France) in WDS Mode. Fourteen tourmaline samples with their face oriented parallel to the principal axis, cut and polished down to thin sections, showed polarized spectra of two broad absorption bands at approximately 14000 cm-1 (715 nm) and 24000 cm-1 (417 nm). Precision thickness measurements were used to calculate the absorption coefficients α. For the absorption around 24000 cm-1, a linear correlation was observe…

tourmalineMicroscopeTourmalineChemistryAnalytical chemistrychemistry.chemical_elementGeneral ChemistryElectron microprobeMicrobeamIntervalence charge transferSpectral linelaw.inventionlawIVCT effecttitaniumAbsorption (electromagnetic radiation)Titanium
researchProduct