Search results for "Microscope"
showing 10 items of 1412 documents
Peculiarities of imaging one- and two-dimensional structures in an emission electron microscope. 1. theory
2000
Local changes in work function cause deviations of the electrical microfield near a sample surface as a result of the uniform accelerating field distribution between the sample (cathode) and the extractor electrode (anode). This results in a change in the electron trajectories. As a consequence, the microscope image shows remarkable changes in position, size, intensity and lateral resolution of distinct details, which can be quantitatively described by the calculations presented here. Analysing these effects in the image gives an opportunity to determine the real lateral size of the observed structures and the distribution of local contact potentials.
Probing of nanocontacts inside a transmission electron microscope
2007
In the past twenty years, powerful tools such as atomic force microscopy have made it possible to accurately investigate the phenomena of friction and wear, down to the nanometer scale. Readers of this book will become familiar with the concepts and techniques of nanotribology, explained by an international team of scientists and engineers, actively involved and with long experience in this field. Edited by two pioneers in the field, 'Fundamentals of Frictions and Wear at the Nanoscale' is suitable both as first introduction to this fascinating subject, and also as a reference for researchers wishing to improve their knowledge of nanotribology and to keep up with the latest results in this …
Spatially-multiplexed interferometric microscopy (SMIM): converting a standard microscope into a holographic one
2014
We report on an extremely simple, low cost and highly stable way to convert a standard microscope into a holographic one. The proposed architecture is based on a common-path interferometric layout where the input plane is spatially-multiplexed to allow reference beam transmission in a common light-path with the imaging branch. As consequence, the field of view provided by the layout is reduced. The use of coherent illumination (instead of the broadband one included in the microscope) and a properly placed one-dimensional diffraction grating (needed for the holographic recording) complete the experimental layout. The proposed update is experimentally validated in a regular Olympus BX-60 upri…
Dopant Contrast in Semiconductors as Interpretation Challenge at Imaging by Electrons
2007
Mechanisms responsible for the contrast between differently doped areas in semiconductors, which is observed in electron micrographs, is discussed as regards the key factors determining the sign and magnitude of the contrast. Experimental data obtained by means of the scanning electron microscope (SEM), scanning low energy electron microscope and photoelectron emission microscope are reviewed together with hints following from them for compilation of a model of the contrast mechanism.
The future of transmission electron microscopy (TEM) in biology and medicine.
2000
1996
The uses of atomic force microscopy, scanning tunneling microscopy, electron spectroscopic imaging, electron energy loss spectroscopy and low voltage, high resolution scanning electron microscopy in polymer research are reviewed
Template electrosynthesis of aligned Cu2O nanowires
2008
Abstract Large arrays of aligned copper oxide nanowires were produced by electrodeposition, using anodic alumina membranes as template. We have studied the effect of two fundamental parameters involved in fabrication process: potential perturbation and bath composition. Performing electrodeposition from a copper acetate/sodium acetate bath (pH 6.5), we found that chemical composition of nanowires varied in dependence on the shape of the applied potential perturbation: pure copper oxide nanowires were produced by pulsed potential, whilst continuous electrodeposition resulted in a co-deposition of Cu and Cu 2 O. In a copper lactate bath, buffered at pH 10, the shape of perturbation did not in…
Grafting and characterization of dodecylphosphonic acid on copper: Macro-tribological behavior and surface properties
2013
International audience; Thin film of n-dodecylphosphonic acid (DDPA) was prepared on a copper oxide substrate via a molecular self-assembly process. The composition, structure, organization, surface energy, morphology, and electrochemical behavior of the DDPA filmwere characterized bymeans of X-ray photoelectron spectroscopic analysis (XPS), polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS), contact angle measurement v(CAM), microscopic observations, and electrochemistry. The friction behavior of the DDPA film adsorbed on copper oxide substrate sliding against a Si3N4 ball was examined on a linear reciprocating tribological tester. Worn surfaces of the DDPA film…
Electronic Excitation Energy Transfer in Multichromophoric Assemblies: A Single Molecule Insight
2009
In recent years, single molecule spectroscopy has provided novel insights into the fundamentals of electronic excitation energy transfer in molecular aggregates. In order of increasing structural complexity, we have studied simple molecular dimers and multichromophoric dendrimers. It will be shown that the combination of frequency-selective single molecule spectroscopy and confocal fluorescence microscopy at 1.4 K is a unique tool to study energy transfer processes in these systems. In particular, from the line widths of single molecule excitation spectra, rate constants of energy transfer can be deduced directly. A detailed analysis shows that, for several cases, the mechanism of energy tr…
Removal of Escherichia coli from Saturated Sand Columns Supplemented with Hydrochar Produced from Maize
2014
Despite numerous studies on hydrochar use, its application in water treatment for pathogen removal remains unexplored. In this study, we evaluated the efficiency of hydrochar produced from crop residue of maize for water treatment by determining Escherchia coli breakthrough from sand columns supplemented with hydrochar. To enhance the adsorptive capacity, raw hydrochar was activated by 1 mol L⁻¹ KOH at room temperature. The experiments conducted in a 10-cm sand bed with 1.5% (w/w) activated and raw hydrochar supplements, not activated by KOH, showed 93 and 72% of E. coli removal efficiencies, respectively. Activation of KOH not only enhanced the E. coli removal but also increased the streng…