Search results for "Microscope"
showing 10 items of 1412 documents
Spray pyrolytic deposition of ZnO thin layers composed of low dimensional nanostructures
2010
Abstract ZnO nanolayers composed of fine nanostructures have been successively grown by spray pyrolytic deposition at 300 ∘ C over amorphous glass substrates. As deposited samples were analysed by scanning electron microscopy (SEM), showing a granular morphology with grain size in the limit of the microscope resolution. CL measurement shows a broad near band edge (3.4 eV) emission of ZnO in the UV region and the defect level emissions in the green region of the spectrum. The use of intermittent spray pyrolytic deposition is shown as an alternative to increase the homogeneity of the samples when temperatures near to the precursor pyrolytic decomposition is selected, long depositions times a…
Two-photon high-speed light-sheet volumetric imaging of brain activity during sleep in zebrafish larvae
2020
Although it is well known that zebrafish display the behavioural signature of sleep, the neuronal correlates of this state are not yet completely understood, due to the complexity of the measurements required. For example, when performed with visible excitation light, functional imaging can disrupt the day/night cycle due to the induced visual stimulation. To address this issue, we developed a custom-made two-photon light-sheet microscope optimized for high-speed volumetric imaging. By employing infra-red light (not visible to the larva) for excitation, we are able to record wholebrain neuronal activity with high temporal- and spatial-resolution without affecting the sleep state. In two-pho…
Nano-lithography using a resist, patterned by electron exposure in an AFM configuration
1996
We have used a metallised force microscope tip to apply a voltage and thereby expose a very thin resist film. It is possible to image the film surface before, during and after the exposure, without interference with the process. Uniform resist films as thin as 10 nm are fabricated using the Langmuir-Blodgett technique. To orient the defined pattern and to make electrical connections a special larger scale alignment structure is first defined by conventional electron beam lithography, either directly in the Langmuir-Blodgett resist film or in a complete first process with a separate resist system. The results from the one resist process gave conducting 50 nm lines in a 60 A thick aluminium f…
Fast Axial-Scanning Widefield Microscopy With Constant Magnification and Resolution
2015
In this paper, we propose the use of electrically-addressable lens devices for performing fast non-mechanical axial scanning when imaging three-dimensional samples. This non-mechanical method can be implemented in any commercial microscope. The approach is based on the insertion of the tunable lens at the aperture stop of the microscope objective. By tuning the voltage, a stack of depth images of 3D specimens can be captured in real time and with constant magnification and resolution. The main advantage of our technique is the possibility of performing fast axial scanning free of mechanical vibrations.
The Effect of Building Direction on Microstructure and Microhardness during Selective Laser Melting of Ti6Al4V Titanium Alloy
2021
AbstractDuring the last few years, additive manufacturing has been more and more extensively used in several industries, especially in the aerospace and medical device fields, to produce Ti6Al4V titanium alloy parts. During the Selective Laser Melting (SLM) process, the heterogeneity of finished product is strictly connected to the scan strategies and the building direction. An optimal managing of the latter parameters allows to better control and defines the final mechanical and metallurgical properties of parts. Acting on the building direction it is also possible to optimize the critical support structure. In particular, more support structures are needed for the sample at 0°, while very…
Axial gain resolution in optical sectioning fluorescence microscopy by shaded-ring filters.
2009
We present a new family of pupil masks to control the axial component of the intensity distribution in the focal region of tightly focused light fields. The filters, which consist of a circular clear pupil with a single shaded ring, allow to control the width of the central lobe of the axial spot together with the residual sidelobes energy. The filters can be applied to improve the optical sectioning capacity of different scanning microscopes.
Partially Coherent Optical Diffraction Tomography Toward Practical Cell Study
2021
Optical diffraction tomography (ODT) is a computational imaging technique based on refractive index (RI) contrast. Its application for microscopic imaging of weakly absorbing and scattering samples has been demonstrated by using a specially designed holographic microscope with angular scanning of the coherent sample illumination direction. Recently, an alternative low cost technique based on partially coherent sample illumination (PC-ODT), which is compatible with the conventional wide-field transmission microscope, has been established. In this case, the 3D refractive index distribution of the sample is obtained by deconvolution from a single stack of through-focus intensity images. The pe…
Heat under the microscope
2014
[Introduction] Recent advances in computational and spectroscopic tools offer new insights into the nature of thermal conduction at ever-finer length scales and ways to control it. Heat conduction is familiar to us all and yet requires a wide range of physics—statistical mechanics, crystallography, and quantum mechanics among them—to fully explain. At the macroscale, heat conduction can be described as a diffusion process in which energy moves along a temperature gradient. The heat flux dissipated by the gradient depends on a material property, the thermal conductivity, as described by the constitutive relation, Fourier’s law. The heat equation, which is derived from Fourier’s law and the c…
Electrogeneration of Diiodoaurate in Dimethylsulfoxide on Gold Substrate and Localized Patterning
2016
International audience; A localized etching of gold surface by scanning electrochemical microscope technique is presented where a dimethylsulfoxide-based electrolyte charged with iodine is used. The electrogenerated triiodide ion at the platinum ultramicroelectrode tip (feedback mode) acts as an oxidant for gold surface. The effects of electrode diameter and the bias time have been investigated. The approach curve method was used to hold the electrode tip close to the gold surface. A scanning electron microscope is used to observe the etched gold surfaces where disk-shaped dots are generated. The diameter of these holes depends directly on the Pt electrode diameter and the bias time.
One-Step Anionic Copolymerization Enables Formation of Linear Ultrahigh-Molecular-Weight Block Copolymer Films Featuring Vivid Structural Colors in t…
2018
Ultrahigh-molecular-weight (UHMW) tapered block copolymers (BCPs) consisting of polyisoprene-block-poly(4-methylstyrene) featuring overall molar masses in the range of 1101–2033 kg mol–1 (Mw) are synthesized via a convenient one-step anionic copolymerization protocol. The obtained UHMW BCPs are investigated by differential scanning calorimetry, size exclusion chromatography, and 1H NMR spectroscopy. Microphase separation for the UHMW BCPs in the bulk state is investigated by transmission electron microscopy (TEM) measurements and scanning electron microscopy (SEM), revealing well-ordered lamellar and spherical domains with large domain sizes in the range of 100–200 nm. Excellent order and p…