Search results for "Monochromator"
showing 4 items of 14 documents
IMAGINE: A Cold Neutron Imaging Station at the Laboratoire Léon Brillouin
2015
International audience; A second cold neutron imaging station has been open to users at the Laboratoire Léon Brillouin. The station is designed for high resolution neutron imaging and tomography. The typical field of view is 100x100 mm2 with a spatial resolution of 100 μm. Betterspatial resolutions (∼50 μm) can be achieved when reducing the field of view down to 30x30mm2. The L/D ratio can be varied from 200 to1000with pinhole sizes ranging from 20 to7 mm. Future upgrades will provide capabilities for energy resolved measurements using either a velocity selector or a double crystal monochromator. The possibility to perform polarized neutron experiments will also be provided next year.
Photoemission microscopy with microspot-XPS by use of undulator radiation and a high-throughput multilayer monochromator at BESSY
1999
We present a new experiment for photoelectron microspectroscopy by use of undulator radiation, which has been set up at the beamline U2 at the Berlin electron storage ring BESSY 1. This approach employs a non-imaging simulated hemispherical electron energy analyser attached to an imaging photoemission electron microscope (FOCUS IS-PEEM) with integrated microarea selector. The photoemission microscope exhibits a lateral resolution of 25 nm (with 4.9 eV UV-excitation), while the resolution with incident synchrotron radiation in the soft X-ray range is about 100-120 nm (mainly due to chromatic aberrations). Photoemission microscopy as well as photoelectron microspectroscopy of selected areas o…
Time resolved emission at 1.3 μm of a single InAs quantum dot by using a tunable fibre Bragg grating
2013
Photoluminescence and time resolved photoluminescence from single metamorphic InAs/GaAs quantum dots (QDs) emitting at 1.3 mu m have been measured by means of a novel fibre-based characterization set-up. We demonstrate that the use of a wavelength tunable fibre Bragg grating filter increases the light collection efficiency by more than one order of magnitude as compared to a conventional grating monochromator. We identified single charged exciton and neutral biexciton transitions in the framework of a random population model. The QD recombination dynamics under pulsed excitation can be understood under the weak quantum confinement potential limit and the interaction between carriers at the …
Progress in HAXPES performance combining full-field k-imaging with time-of-flight recording
2019
Journal of synchrotron radiation 26(6), 1996-2012 (2019). doi:10.1107/S1600577519012773