Search results for "Monolith"
showing 10 items of 90 documents
Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
2019
Background The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. Material and methods 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then e…
Self-packed core shell nano liquid chromatography columns and silica-based monolithic trap columns for targeted proteomics.
2016
Self-preparation of nano liquid chromatography (nLC) columns has advantages regarding cost and flexibility. For targeted proteomics, we evaluated several approaches for particle-packing nLC columns and manufacturing fritless silica-based monolithic trap columns (50μm inner diameter). Our preferred approach for nLC column preparation was to magnetically stir Accucore core shell particles (C18 stationary phase) in ACN/water (80/20, v/v) suspensions during pressure-driven filling of polymer-fritted standard fused silica capillaries. The columns were ready for use about one hour after preparation had begun. They had comparable peak capacities (peptides) to commercial columns, and satisfactory w…
Design and implementation of PET detectors based on monolithic crystals and SiPMs
2018
Esta tesis doctoral se centra tanto en el diseño como en la validación experimental de detectores de rayos gamma para escáneres de tomografía por emisión de positrones (PET, del inglés Positron Emission Tomography). El objetivo principal de esta tesis es el diseño de innovadores bloques detectores PET de alto rendimiento. La técnica PET constituye una de las principales herramientas diagnósticas en medicina nuclear, que es una especialidad médica que utiliza sustancias radiactivas con fines diagnósticos y terapéuticos. Esta técnica de imagen médica permite visualizar procesos fisiológicos y bioquímicos del cuerpo humano in vivo, mediante la administración del elemento radiotrazador. Los rad…
Performance of a Chromolith RP-18e column for the screening of β-blockers
2009
The chromatographic performance of a monolithic column (Chromolith RP-18e) was comprehensively examined in the isocratic separation of ten beta-blockers, using ACN-water mobile phases, and compared with the performance of three microparticulate RP columns manufactured with different types of silica: Spherisorb ODS-2, Kromasil C18 and XTerra MS C18. The comparison considered the analysis time, selectivity, peak shape (column efficiency and asymmetry) and resolution, and was extended to a wide range of mobile phase compositions. The Chromolith column showed good performance for the analysis of beta-blockers with regard to the packed columns. In terms of selectivity and analysis time, the grea…
“A Miracle of Architecture”: The Billiemi limestone Columns of the Church of San Giuseppe dei Teatini in Palermo and Domenico Fontana’s Method for Li…
2014
La chiesa di San Giuseppe dei Teatini di Palermo (costruita a partire dal 1619), è un’architettura singolare nel panorama internazionale del Sei-Settecento. La realizzazione di una spregiudicata conformazione basilicale con copertura a volte, impostata su una sequenza di colonne monolitiche giganti nelle navate e nella crociera con cupola con sostegni alti fino a 10m, è il risultato della convergenza di più fattori. Il conseguimento di questo traguardo si deve alla scoperta nel territorio di Palermo, alla fine del XVI secolo, di un calcare compatto (il “Billiemi”) dalle qualità estetiche e strutturali assimilabili al marmo e in grado di generare poderosi monoliti. Questa opportunità innescò…
Acrylate ester-based monolithic columns for capillary electrochromatography separation of triacylglycerols in vegetable oils
2011
Abstract A simple and reliable method for the evaluation of triacylglycerols (TAGs) in vegetable oils by capillary electrochromatography (CEC) with UV–Vis detection, using octadecyl acrylate (ODA) ester-based monolithic columns, has been developed. The percentages of the porogenic solvents in the polymerization mixture, and the mobile phase composition, were optimized. The optimum monolith was obtained at the following ratios: 40:60% (wt/wt) monomers/porogens, 60:40% (wt/wt) ODA/1,3-butanediol diacrylate and 23:77% (wt/wt) 1,4-butanediol/1-propanol (14 wt% 1,4-butanediol in the polymerization mixture). A satisfactory resolution between TAGs was achieved in less than 12 min with a 65:35 (v/v…
Classification of extra virgin olive oils according to their geographical origin using phenolic compound profiles obtained by capillary electrochroma…
2009
Abstract A simple and reliable method for the evaluation of the phenolic fraction of extra virgin olive oils (EVOO) by capillary electrochromatography (CEC) with UV–Vis detection, using lauryl acrylate (LA) ester-based monolithic columns, has been developed. The percentages of the porogenic solvents in the polymerization mixture, and the mobile phase composition, were optimized. The optimum monolith was obtained with a monomers/porogens ratio of 40:60% (wt/wt) using a LA/1,3-butanediol diacrylate ratio of 70:30% (wt/wt) and a 1,4-butanediol/1-propanol ratio of 25:75% (wt/wt). A satisfactory resolution between the phenolic compounds was achieved in less than 25 min with a 15:85 (v/v) ACN–wat…
Nanoscale Chemical Interaction Enhances the Physical Properties of Bioglass Composites
2013
Bioglasses are favorable biomaterials for bone tissue engineering; however, their applications are limited due to their brittleness. In addition, the early failure in the interface is a common problem of composites of bioglass and a polymer with high mechanical strength. This effect is due to the phase separation, nonhomogeneous mixture, nonuniform mechanical strength, and different degradation properties of two compounds. To address these issues, in this study a nanoscale interaction between poly(methyl methacrylate) (PMMA) and bioactive glass was formed via silane coupling agent (3-trimethoxysilyl)propyl methacrylate (MPMA). A monolith was produced at optimum composition from this hybrid …
Influence of the chemical composition of monolithic zirconia on its optical and mechanical properties. Systematic review and meta-regression.
2021
Este artículo se encuentra disponible en la siguiente URL: https://www.jstage.jst.go.jp/article/jpr/66/2/66_JPR_D_20_00218/_pdf/-char/en Este artículo de investigación pertenece al número especial "Advances in Personalized Nursing Care". Purpose: This systematic review set out to investigate the influence of chemical composition and specimen thickness of monolithic zirconia on its optical and mechanical properties. Meta-analysis and meta-regression analyzed the effects of variations in percentages of yttrium, aluminum, and specimen thickness of monolithic zirconia. Study selection: The review followed recommendations put forward in the PRISMA checklist. An electronic search for relevant art…
Interpretive optimisation of organic solvent content and flow-rate in the separation of β-blockers with a Chromolith RP-18e column
2009
The chromatographic performance of a Chromolith RP-18e column was comprehensively examined for a group of basic drugs (beta-blockers), eluted with isocratic ACN-water mixtures at increasing flow-rate up to 6 mL/min. As the flow-rate increases at fixed mobile phase composition, peak distribution (selectivity) is maintained, but the relative peak widths increase. This reduces the resolution below satisfactory values for closely eluting compounds. With the monolithic column, flow-rate becomes thus an important factor to be optimised, in addition to the mobile phase composition. Since, theoretically, retention factors (k) are independent of the flow-rate, the classical quadratic model relating …