Search results for "Monolith"

showing 10 items of 90 documents

Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins

2007

In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Bo…

ChromatographyMonolithic HPLC columnSilicon dioxideElutionOrganic ChemistryAnalytical chemistryProteinsReproducibility of ResultsGeneral MedicineReversed-phase chromatographySilicon DioxideBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryVolumetric flow ratechemistry.chemical_compoundchemistryPhase (matter)PeptidesMesoporous materialPorosityChromatography LiquidJournal of Chromatography A
researchProduct

Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses

2017

The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…

Dental Stress AnalysisMaterials scienceGlass ionomer cementDentistryDental Abutments02 engineering and technologyBendingVeneering ceramicDental Materials03 medical and health sciences0302 clinical medicineMaterials TestingCubic zirconiaDental Restoration FailureGeneral Dentistrybusiness.industryFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyDental VeneersGlass Ionomer CementsCeramics and CompositesFracture (geology)Computer-Aided DesignDenture Partial FixedZirconium0210 nano-technologybusinessDental Materials Journal
researchProduct

Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…

2018

PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…

Dental Stress AnalysisMaterials scienceMetal Ceramic AlloysDental Abutments02 engineering and technologyCrossheadDental MaterialsRandom Allocation03 medical and health sciences0302 clinical medicineMaterials TestingFixed partial denturesCubic zirconiaDental Restoration FailureComposite materialGeneral DentistryUniversal testing machineFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyMetal ceramicDental VeneersFracture (geology)Computer-Aided DesignDenture Partial FixedStress MechanicalZirconium0210 nano-technologyJournal of Prosthodontics
researchProduct

Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to c…

2011

Abstract The performance of a monolithic C 18 column (150 mm × 0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C 18 column (150 mm × 0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorp…

Detection limitAnalyteChromatographyMonolithic HPLC columnTriazinesCapillary actionPhenylurea CompoundsOrganic ChemistryDinitroanilineAnalytical chemistryReproducibility of ResultsContext (language use)General MedicineSolid-phase microextractionSensitivity and SpecificityBiochemistryAnalytical Chemistrychemistry.chemical_compoundOrganophosphorus CompoundschemistryChromatography columnSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Sensitive determination of parabens in human urine and serum using methacrylate monoliths and reversed-phase capillary liquid chromatography-mass spe…

2014

A method for the determination of parabens in human urine and serum by capillary liquid chromatography (cLC) with UV-Vis and mass spectrometry (MS) detection using methacrylate ester-based monolithic columns has been developed. The influence of composition of polymerization mixture was studied. The optimum monolith was obtained with butyl methacrylate monomer at 60/40% (wt/wt) butyl methacrylate/ethylene dimethacrylate ratio and 50wt% porogens (composed of 36wt% of 1,4-butanediol, 54wt% 1-propanol and 10wt% water). Baseline resolution of analytes was achieved through a mobile phase of acetonitrile/water in gradient elution mode. Additionally, dispersive liquid-liquid microextraction (DLLME)…

Detection limitAnalytegeographyChromatography Reverse-PhaseChromatographygeography.geographical_feature_categoryResolution (mass spectrometry)ChemistryOrganic ChemistryParabensGeneral MedicineUrineUrinalysisMethacrylateMass spectrometryBiochemistryMass SpectrometryAnalytical ChemistryLiquid chromatography–mass spectrometryLimit of DetectionHumansMethacrylatesMonolithBlood Chemical AnalysisJournal of chromatography. A
researchProduct

In-tube solid-phase microextraction and liquid chromatography using a monolithic column for the selective determination of residual ethylenediamine i…

2009

The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 microm thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed thro…

Detection limitChromatographyMonolithic HPLC columnPolydimethylsiloxaneCapillary actionPolymersCationic polymerizationSolid-phase microextractionEthylenediaminesAnalytical Chemistrychemistry.chemical_compoundchemistryChemical IndustryIndicators and ReagentsDerivatizationDimethylamineSolid Phase MicroextractionChromatography LiquidAnalytical chemistry
researchProduct

Evaluation of 2,3-epoxypropyl groups and functionalization yield in glycidyl methacrylate monoliths using gas chromatography

2014

Abstract Poly(glycidyl methacrylate- co -ethylene dimethacrylate) (poly(GMA- co -EDMA)) is most frequently used as parent monolith to obtain stationary phases with a variety of surface chemistries for liquid chromatography and capillary electrochromatography. Functionalization is performed by opening the accessible 2,3-epoxypropyl groups of the monolith with a suitable reagent. The number of 2,3-epoxypropyl groups which are accessible before and after the functionalization reaction, and the grafting yield, are important parameters, required both to optimize functionalization and to interpret the chromatographic performance of functionalized monoliths. In this work, a method capable of provi…

DiethylaminegeographyCapillary electrochromatographyGlycidyl methacrylateChromatography Gasgeography.geographical_feature_categoryChromatographyOrganic ChemistryGeneral MedicineSilicon DioxideLithium aluminium hydrideMethacrylateBiochemistryChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundchemistryCapillary ElectrochromatographyReagentEpoxy CompoundsMethacrylatesMethylmethacrylatesSurface modificationMonolithJournal of Chromatography A
researchProduct

High resolution 80Se(n,γ) cross section measurement at CERN n_TOF and development of the novel i-TED detection system

2022

El proceso (-s) de captura lenta de neutrones es responsable de la formación de la mitad de los elementos más pesados ​​que el hierro en el universo. A pesar de la larga escala de tiempo de este proceso, la larga vida media de algunos isótopos inestables a lo largo del flujo de reacción del proceso-s crea puntos de ramificación que conducen a una división de la ruta de la nucleosíntesis. 79Se (t1/2 = 3.27 x 10^5 y) representa uno de los núcleos ramificados-s más relevantes y debatidos por dos razones principales. Por un lado, la existencia de estados excitados de baja energía en el 79Se, cuya población puede variar con la temperatura del medio estelar, hace que el patrón de abundancia local…

Dynamic Electronic Collimationbranching pointPETsys Electronicsnucleosynthesisi-TEDprompt-gammaUNESCO::FÍSICA::Física atómica y nuclear ::Física nuclear experimental bajas energíasneutron capture cross sectionnuclear physics79Se:FÍSICA::Física atómica y nuclear ::Física nuclear experimental bajas energías [UNESCO]time of flightmonolithic scintillation crystalMACStotal energy detectorsbackground rejectionsilicon photomultipliers-processCompton camera80Se
researchProduct

Quasifractal planar microstrip resonators for microwave circuits

1999

We propose a new shape for microwave planar circuits using the self-similarity of the fractal geometry. This new shape allows the generation of numerous resonant frequencies for this microwave planar resonator due to the surface's encasing. The resonant frequency assessment can be useful for the concept of filters or wide frequency band matching loads as examples, without consuming circuit surface. ©1999 John Wiley & Sons, Inc. Microwave Opt Technol Lett 21: 433–436, 1999.

Engineeringbusiness.industryFrequency bandMicrowave engineeringCondensed Matter PhysicsAtomic and Molecular Physics and OpticsMicrostripElectronic Optical and Magnetic MaterialsResonatorPlanarElectronic engineeringOptoelectronicsElectrical and Electronic EngineeringbusinessMicrowaveMonolithic microwave integrated circuitElectronic circuitMicrowave and Optical Technology Letters
researchProduct

A Novel Approach to the Characterization and Modelig of Microwave Transistor Packages

1994

A novel approach to the characterization and modeling of microwave transistor packages through dedicated VNA measurements is presented. By combining a multi-step partitioning method with the use of purposely realized - but technologically simple - "package style" test devices, the proposed technique permits to derive in a systematic manner an equivalent circuit for both the transistor package and the test-fixture mount employed for the characterization. Since it does not rely on the indirect, optimization-based, conventional extraction methods of the literature, nor on a simplified circuit structure for the overall parasitic fourport embedding the active device, it is able to provide a high…

Engineeringbusiness.industryTransistorSystem testingChiplaw.inventionNonlinear systemlawElectronic engineeringEquivalent circuitEmbeddingCoaxialbusinessMonolithic microwave integrated circuit24th European Microwave Conference, 1994
researchProduct