Search results for "Monolithic hplc column"
showing 10 items of 32 documents
Photografted fluoropolymers as novel chromatographic supports for polymeric monolithic stationary phases
2018
[EN] In this study, porous polymer monoliths were in situ synthesized in fluoropolymers tubing to prepare microbore HPLC columns. To ensure the formation of robust homogeneous polymer monoliths in these housing supports, the inner surface of fluoropolymer tubing was modified in a two-step photografting process. Raman spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the inner poly(ethylene-co-tetrafluoroethylene) (ETFE) wall and the subsequent attachment of a monolith onto the wall. Poly(glycidyl methacrylate-co-divinylbenzene), poly(butyl methacrylate-co-ethyleneglycol dimethacrylate) and poly(styrene-co-divinylbenzene) monoliths were in situ synt…
Particle packed columns and monolithic columns in high-performance liquid chromatography-comparison and critical appraisal
2007
The review highlights the fundamentals and the most prominent achievements in the field of high-performance liquid chromatography (HPLC) column development over a period of nearly 50 years. After a short introduction on the structure and function of HPLC columns, the first part treats the major steps and processes in the manufacture of a particle packed column: synthesis and control of particle morphology, sizing and size analysis, packing procedures and performance characterization. The next section is devoted to three subjects, which reflect the recent development and the main future directions of packed columns: minimum particle size of packing, totally porous vs. core/shell particles an…
RpeakChrom: Novel R package for the automated characterization and optimization of column efficiency in high-performance liquid chromatography analys…
2017
Characterization of chromatographic columns using the traditional van Deemter method is limited by the necessity of calculating extra-column variance, issue particularly relevant when modeling asymmetrical peaks eluted from monolithic columns. A novel R package that implements Parabolic Variance Modified Gaussian approach for accurate peak modeling, van Deemter equation and two alternatives approaches, based on van Deemter, has been developed to calculate the height equivalent to a theoretical plate (HETP). To assess package capabilities conventional packed reverse-phase and monolithic HPLC columns were characterized. Peaks eluted from the monolithic column showed a high value of factor asy…
Comparison of monolithic and microparticulate columns for reversed-phase liquid chromatography of tryptic digests of industrial enzymes in cleaning p…
2011
Abstract Enzymes of several classes used in the formulations of cleaning products were characterized by trypsin digestion followed by HPLC with UV detection. A polymeric monolithic column (ProSwift) was used to optimize the separation of both the intact enzymes and their tryptic digests. This column was adequate for the quality control of raw industrial enzyme concentrates. Then, monolithic and microparticulate columns were compared for peptide analysis. Under optimized conditions, the analysis of tryptic digests of enzymes of different classes commonly used in the formulation of cleaning products was carried out. Number of peaks, peak capacity and global resolution were obtained in order t…
Study of peak shape and efficiency in butyl acrylate-based monolithic columns for capillary electrochromatography.
2009
Abstract The study and modelling peak shape of in capillary electrochromatography (CEC), obtained using butyl acrylate (BA)-based monolithic columns, is described in this article. A modified-Gaussian model, which is a function of conventional experimental parameters: retention time (tR), peak height (H0) and standard deviation (σ0) at the peak maximum, and left (A) and right (B) halfwidths, was used to describe the peaks of thiourea and several polyaromatic hydrocarbons compounds, which were eluted under several applied voltages. A mean relative error below 2% in the prediction of peak shape is obtained. Based on peak parameters, an easy and reliable estimation of global chromatographic per…
Fast high performance liquid chromatography analysis in lipidomics: Separation of radiolabelled fatty acids and phosphatidylcholine molecular species…
2006
Abstract HPLC procedures using conventional C 18 columns are usually used to separate simple and complex lipid mixtures but these methods of separation remain often laborious and very slow. Here, monolithic columns were successfully applied to separate lipids – radiolabelled fatty acid mixtures and individual phosphatidylcholine (PC) molecular species. For that, isocratic elution was performed using two Chromolith™ Performance RP-18e columns connected in series. Detection was achieved by online measurement of radioactivity for radiolabelled fatty acids and by UV absorbance at 205 nm for PC molecular species. The performances of such silica rods were compared to conventional reverse-phase si…
Fast determination of prominent carotenoids in tomato fruits by CEC using methacrylate ester-based monolithic columns.
2007
In this study, the major carotenoids (beta-carotene and lycopene) present in tomato fruits were analyzed by CEC with a methacrylate ester-based monolithic column. The effects of the porogenic solvent ratio, and the hydrophobicity of bulk monomer employed were examined on carotenoids separations. A fast separation of these analytes was achieved in less than 5.0 min in a mobile phase containing 35% THF, 30% ACN, 30% methanol, and 5% of a 5 mM Tris aqueous buffer, pH 8, with lauryl methacrylate-based monoliths. The CEC method was evaluated in terms of detection limit and reproducibility (retention time, area, and column preparation) with values below 1.6 microg/mL and 7.2%, respectively. The p…
Peptide mapping by reversed-phase high-performance liquid chromatography employing silica rod monoliths.
2003
In this paper, a general procedure is described for the generation of peptide maps of proteins with monolithic silica-based columns. The peptide fragments were obtained by tryptic digestion of various cytochrome c species with purification of the tryptic fragments achieved by reversed-phase high-performance liquid chromatographic methods. Peak assignment of the various peptides was based on evaluation of the biophysical properties of the individual peptides and via mass spectrometric identification. The performance of several different monolithic sorbents prepared as columns of identical cross-sectional dimensions were investigated as part of these peptide mapping studies and the data evalu…
Reliable and simple analytical methods for determination of citrulline and metabolically related amino acids by liquid chromatography after derivatiz…
2014
We describe the development of a high-performance liquid chromatography (HPLC) method for the determination of citrulline and other amino acids relevant to intestinal diseases. The amino acids were derivatized with 9-fluorenylmethylchloroformate (FMOC-Cl) and their derivatives were separated on two different columns, a core-shell column (Halo C18) and a silica-based monolith (Chromolith Performance RP-18). The derivatization reaction was optimized with respect to pH, buffer concentration and reproducibility. The optimal derivatization conditions were achieved with 0.4 M borate buffer at pH 9.20, a constant ratio of FMOC-Cl/total amino acids (10 : 1) and 75 mM tyramine after 1 min (quenching…
Methacrylate ester-based monolithic columns for nano-LC separation of tocopherols in vegetable oils
2010
The separation and determination of tocopherols (Ts) in vegetable oils by nano-LC chromatography with UV-vis detection using lauryl methacrylate ester-based monolithic columns has been developed. The separation of Ts was optimized in terms of mobile phase composition on the basis of the best compromise among efficiency, resolution and analysis time. Using a mobile phase composed of ACN/methanol/water, an excellent resolution between Ts was achieved within 18 min. The LODs were lower than 0.26 μg/mL, being repeatability values of retention time and peak area below 0.15 and 3.1%, respectively. The method was applied to the quantification of Ts and tocotrienols present in several vegetable oil…