Search results for "Monte Carlo method."
showing 10 items of 1217 documents
Jet mass and substructure of inclusive jets in $ \sqrt {s} = 7\;{\text{TeV}} $ pp collisions with the ATLAS experiment
2012
Recent studies have highlighted the potential of jet substructure techniques to identify the hadronic decays of boosted heavy particles. These studies all rely upon the assumption that the internal substructure of jets generated by QCD radiation is well understood. In this article, this assumption is tested on an inclusive sample of jets recorded with the ATLAS detector in 2010, which corresponds to 35 pb-1 of pp collisions delivered by the LHC at √s = 7TeV. In a subsample of events with single pp collisions, measurements corrected for detector efficiency and resolution are presented with full systematic uncertainties. Jet invariant mass, kt splitting scales and N-subjettiness variables are…
Exploration of jet substructure using iterative declustering in pp and Pb–Pb collisions at LHC energies
2020
The ALICE collaboration at the CERN LHC reports novel measurements of jet substructure in pp collisions at $\sqrt{s}$= 7 TeV and central Pb-Pb collisions at $\sqrt{s_{\rm{NN}}}$ = 2.76 TeV. Jet substructure of track-based jets is explored via iterative declustering and grooming techniques. We present the measurement of the momentum sharing of two-prong substructure exposed via grooming, the $z_{\rm{g}}$, and its dependence on the opening angle, in both pp and Pb-Pb collisions. We also present the first measurement of the distribution of the number of branches obtained in the iterative declustering of the jet, which is interpreted as the number of its hard splittings. In Pb-Pb collisions, we…
Dosimetric evaluation of internal shielding in a high dose rate skin applicator
2011
Purpose: The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. Material and methods: Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in …
Insights into the derivative-based method for nonlinear mediation models
2022
Associational mediation analysis has generally relied on the linearity of models to estimate the indirect effect as a product of regression coefficients. Very few examples of generalisations to nonlinear settings have been proposed, including a derivative-based method that, however, is far from being widely spread among scholars. In this paper, we clarify some aspects of such an approach to nonlinear mediation models, which have not been addressed by the previous literature. In addition, we run a simulation study to compare confidence intervals for the indirect effect obtained through different approaches.
Study of CT/MRI mutual information based registration applied in brachytherapy
2016
The present work aims to include magnetic resonance imaging (MRI) in a Medical Image-based Graphical platfOrm - Brachytherapy module (AMIGOBrachy) which coupled to the Monte Carlo N-Particle (MCNP6) code allows absorbed dose calculations. Computed tomography (CT) and MRI images were registered using mutual information algorithms to improve tissue segmentation potentially leading to a more accurate treatment planning system.
Technical note: Dosimetric study of a new Co-60 source used in brachytherapy
2007
The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control process on treatment planning systems (TPS), a two-dimensional rectangular dose rate table, coherent with the TG-43U1 dose calculation formalism, is given. These dosimetric data sets can be used as input data of the TPS calculations and to validate them.
SU-FF-T-41: Monte Carlo Dosimetric Study of the New BEBIG Co-60 HDR Source
2005
Purpose: The use of high dose rate brachytherapy (HDR) is a highly extended practice today, being the Ir‐192 the most widely extended isotope used for this type of practice although Co‐60 is also available for HDR. The purpose of this study is to obtain the dosimetric parameters of the Co‐60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there is no dosimetric data available in the literature. It is recommended that accurate dose distribution data, based on a realistic geometry and on the mechanical characteristics of the source, should be obtained by an appropriate method, experimental or Monte Carlo, to be used as input in the HDR Treatment Plannin…
Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources
2008
The two most commonly used modalities of cancer treatment in clinical brachytherapy practice today are high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy. In a clinical treatment, quality dose rate distribution data sets of the brachytherapy sources are required for each source model. The purpose of this study is to obtain detailed dose rate distributions around the new BEBIG HDR and PDR Ir-192 brachytherapy sources. These distributions will then be used as input data in the treatment planning systems dedicated to brachytherapy and its calculations can be verified. The Monte Carlo method was used to obtain the dose rate distributions around the sources studied, taking into accoun…
SU-FF-T-13: Monte Carlo Calculation of the TG-43 Dosimetric Parameters of a New BEBIG Ir-192 HDR Source
2005
Purpose: High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of available dosimetric data for all HDR Ir-192 sources is given, pointing out the lack of data for one of the sources, the used by the BEBIG MultiSource afterloading system (BEBIG GmbH, Germany). The purpose of this study is to obtain detailed dose rate distributions in liquid water media around this source. Material and …
SU-FF-T-329: Monte Carlo Dosimetric Study of the Flexisource Ir-192 HDR Source
2006
Purpose:Brachytherapy with high dose rate (HDR) sources of 192 Ir is a usual practice in clinical brachytherapy today. The TG43 U1 update report recommends that accurate dose distribution data of the brachytherapysource in use should be obtained experimentally or by Monte Carlo (MC), to be used as input in the HDR Treatment Planning System (TPS). The purpose of this study is to obtain the dose rate distribution in liquid water media for the Flexisource HDR 192 Ir source (Isodose Control GmbH, Germany) using the Monte Carlo method to obtain the TG43 U1 parameters and the 2‐D rectangular dose rate table. Material and methods: The MC code GEANT4 (7.1 version) was used to estimate dose rate in …