Search results for "Monte Carlo method."

showing 10 items of 1217 documents

Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya® unit: a Monte Carlo study

2020

Abstract Three different correction factors for measurements with the parallel-plate ionization chamber PTW T34013 on the Esteya electronic brachytherapy unit have been investigated. This chamber type is recommended by AAPM TG-253 for depth-dose measurements in the 69.5 kV x-ray beam generated by the Esteya unit. Monte Carlo simulations using the PENELOPE-2018 system were performed to determine the absorbed dose deposited in water and in the chamber sensitive volume at different depths with a Type A uncertainty smaller than 0.1%. Chamber-to-chamber differences have been explored performing measurements using three different chambers. The range of conical applicators available, from 10 to 30…

Materials scienceRadiological and Ultrasound Technologymedicine.medical_treatmentMonte Carlo methodBrachytherapyConical surface030218 nuclear medicine & medical imagingComputational physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed doseIonization chambermedicineDosimetryRadiology Nuclear Medicine and imagingDepth doseBeam (structure)Physics in Medicine & Biology
researchProduct

Virtual machine concept applied to uncertainties estimation in instrumented indentation testing

2019

The basis of the virtual machine concept, which is commonly used in coordinate measuring machines, was implemented to determine more realistic uncertainties on the estimation of the elastic modulus obtained from nanoindentation tests. The methodology is based on a mathematical model applied to simulate the testing process and to evaluate the uncertainties through Monte Carlo simulations whose application depends on the studied system (instrument, material, scale, etc.). The methodology was applied to the study of fused silica (FQ) and steel samples tested in a nanoindentation system. The results revealed that the most relevant sources of uncertainty are related to the calibration procedure,…

Materials scienceScale (ratio)Basis (linear algebra)Mechanical EngineeringMonte Carlo methodProcess (computing)Mechanical engineering02 engineering and technologyNanoindentation021001 nanoscience & nanotechnologyCondensed Matter Physicscomputer.software_genre01 natural sciences010309 optics[SPI]Engineering Sciences [physics]Mechanics of MaterialsVirtual machine0103 physical sciencesCalibrationGeneral Materials Science0210 nano-technologycomputerElastic modulusComputingMilieux_MISCELLANEOUS
researchProduct

Neutron ESR dosimetry through ammonium tartrate with low Gd content.

2014

This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors present the results obtained by ESR measurements of a blend of ammonium tartrate dosemeters and gadolinium oxide (5 % by weight). The choice of low amount of Gd is due to the need of improving neutron sensitivity while not significantly influencing tissue equivalence. A study of the effect of gadolinium presence on tissue equivalence was carried out. The experiments show that the neutron sensitivity is enhanced by more than an order of magnitude even with this small additive content. Monte Carlo simulations on the increment of energy rele…

Materials scienceSettore ING-IND/20 - Misure E Strumentazione NucleariGadoliniumMonte Carlo methodAnalytical chemistrychemistry.chemical_elementGadoliniumRadiationRadiation Dosagelaw.inventionlawDosimetryRadiology Nuclear Medicine and imagingNeutronElectron paramagnetic resonanceRadiometryTartratesNeutronsRadiationRadiological and Ultrasound Technologyammonium tartratebusiness.industryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyResonanceGeneral MedicineESR Dosimetryneutron dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryMeasuring instrumentNuclear medicinebusinessMonte Carlo MethodRadiation protection dosimetry
researchProduct

Phonon-induced spin relaxation of conduction electrons in silicon crystals

2014

Experimental works managing electrical injection of spin polarization in n-type and p-type silicon have been recently carried out up to room-temperature. In spite of these promising experimental results, a comprehensive theoretical framework concerning the influence of transport conditions on phonon-induced electron spin depolarization in silicon structures, in a wide range of values of lattice temperature, doping concentration and amplitude of external fields, is still at a developing stage. In order to investigate the spin transport of conduction electrons in lightly doped n-type Si crystals, a set of semiclassical multiparticle Monte Carlo simulations has been carried out. The mean spin …

Materials scienceSiliconCondensed matter physicsSpintronicsSpin polarizationPhononMonte Carlo methodsiliconchemistry.chemical_elementElectronSettore FIS/03 - Fisica Della MateriaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)electron spin relaxation.chemistrySpinplasmonicsSpin (physics)Monte Carlo simulation2014 International Workshop on Computational Electronics (IWCE)
researchProduct

Do the contact angle and line tension of surface-attached droplets depend on the radius of curvature?

2018

Results from Monte Carlo simulations of wall-attached droplets in the three-dimensional Ising lattice gas model and in a symmetric binary Lennard-Jones fluid, confined by antisymmetric walls, are analyzed, with the aim to estimate the dependence of the contact angle $(\Theta)$ on the droplet radius $(R)$ of curvature. Sphere-cap shape of the wall-attached droplets is assumed throughout. An approach, based purely on "thermodynamic" observables, e.g., chemical potential, excess density due to the droplet, etc., is used, to avoid ambiguities in the decision which particles belong (or do not belong, respectively) to the droplet. It is found that the results are compatible with a variation $[\Th…

Materials scienceStatistical Mechanics (cond-mat.stat-mech)Tension (physics)Antisymmetric relationMonte Carlo methodNucleationFOS: Physical sciences02 engineering and technologyMechanicsCondensed Matter - Soft Condensed Matter021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciencesRadius of curvature (optics)Contact anglePhysics::Fluid Dynamics0103 physical sciencesThermodynamic limitSoft Condensed Matter (cond-mat.soft)General Materials Science010306 general physics0210 nano-technologyCondensed Matter - Statistical MechanicsLine (formation)
researchProduct

New time-dependent Monte Carlo algorithm designed to model three-phase batch reactor processes: applications on 2,4-dinitro-toluene hydrogenation on …

2003

Abstract The hydrogenation of 2,4-dinitro-toluene on a Pd/C catalyst was employed as a test reaction to simulate, by the time-dependent Monte Carlo method, processes occurring in a three-phase batch reactor working at isobar and isotherm conditions. A new time-dependent Monte Carlo algorithm, including an original subroutine useful to reduce the time of the simulations, was developed and implemented in Fortran language. The paper describes the flowchart of the code together with the main technical details and the involved physical and chemical models. Computational characteristics, such as the simulated time to reach surface steady state conditions and the effects of the catalyst morphology…

Materials scienceSteady stateFortranGeneral Chemical EngineeringNuclear engineeringSubroutineBatch reactorMonte Carlo methodGeneral ChemistryIndustrial and Manufacturing EngineeringDynamic Monte Carlo methodEnvironmental ChemistryKinetic Monte CarloStatistical physicscomputerMonte Carlo algorithmcomputer.programming_languageChemical Engineering Journal
researchProduct

Local structure analysis of the hard-disk fluid near melting

1997

The local structure of the hard-disk fluid is studied across its melting transition by means of Monte Carlo simulations and measurement of a local order parameter. Evidence for a linear behavior of this quantity in an intermediate density range is found, as well as indications for a possible ensemble difference between constant volume and constant pressure simulations within the presently accessible system sizes.

Materials scienceVolume (thermodynamics)Constant pressureMonte Carlo methodRange (statistics)Dynamic Monte Carlo methodStatistical physicsMechanicsConstant (mathematics)Local structurePhysical Review E
researchProduct

Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz

2014

Purpose: In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techniques was compared and the model was validated by experimental fluence and dose determinations. Methods: The depletion calculation code ORIGEN2 was used to compute the burn-up and relevant material composition of each burned fuel element from the day of first reactor operation to its current core. The material composition of the current core was used in a MCNP5 model of the in…

Materials sciencebusiness.industryNuclear engineeringMonte Carlo methodGeneral MedicineTRIGANeutron captureNuclear reactor coreCalibrationDosimetryNeutron sourceNeutronNuclear medicinebusinessMedical Physics
researchProduct

SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap

2016

Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose r…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineCollimated lightAbsorbed dosemedicineDosimetryRadiochromic filmNuclear medicinebusinessDose rateSkin lesionMedical Physics
researchProduct

SU-E-T-516: Limitations and Clinical Implications of the TG-43 Formalism for High-Dose-Rate Skin Brachytherapy

2013

Purpose: In high‐dose‐rate (HDR) skin brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Nowadays, most TPS use the TG‐43 formalism that is based on sources within an infinite water medium, without accounting for the scatter defect due to surrounding air. The purpose of the present study is to evaluate the limitations of the TG‐43 formalism in HDR skin brachytherapy. Methods: This study examined two HDR sources (Ir‐192 and Co‐60) together with a hypothetical Yb‐169 source. Dose distributions were obtained using Monte Carlo methods (i.e., GEANT4). The following configurations were investigated: 1)A typical clinical case consisting …

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineDose distributionFormalism (philosophy of mathematics)Skin surfacemedicineDosimetryClinical caseNuclear medicinebusinessDose rateMedical Physics
researchProduct