Plastic Scintillation Detectors for Time-of-Flight Mass Measurements

2020

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with $^{48}$Ca beam at the NSCL. The new detectors achieved a time resolution ($\sigma$) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the …

PhysicsNuclear and High Energy PhysicsPhotomultiplierScintillationPhysics - Instrumentation and DetectorsResolution (mass spectrometry)010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsDetectorFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Scintillator01 natural sciencesTime of flightOpticsSuperconducting cyclotron0103 physical sciencesNuclear Experiment (nucl-ex)010306 general physicsbusinessInstrumentationNuclear ExperimentBeam (structure)
researchProduct

Low noise scintillation detectors with a P-47 thin layer screen for electrons of several keV

1994

Abstract The applicability of a low-noise scintillation detector (ScD) for the registration of electrons of several keV energy has been studied employing photomultipliers (PM) of different types and sizes. With the application of a sedimented P-47 scintillation screen, the values of the low-energy sensitivity limit and those of the light conversion coefficient were determined as about 2.7–4.7 keV and 2.8–6.6 photoelectrons/keV, respectively, for the set of PM's (Philips-Valvo XP 2020, Philips-Valvo XP 2052, Philips-Valvo XP 2972, EMI 9124a) studied. It is concluded that such scintillation detectors might be used advantageously as electron counters in the range of E > 5 keV. Applications bel…

PhysicsNuclear and High Energy PhysicsPhotomultiplierScintillationRange (particle radiation)Physics::Instrumentation and Detectorsbusiness.industryDetectorElectronScintillatorPhotoelectric effectKinetic energyOpticsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Depth of /spl gamma/-ray interaction within continuous crystals from the width of its scintillation light-distribution

2005

We have studied a new and inexpensive method of measuring the depth of interaction (DOI) in /spl gamma/-ray detectors with large-sized scintillation crystals. This method takes advantage of the strong correlation between the width of the undisturbed light-distribution in continuous crystals and the /spl gamma/-ray's DOI. In order to quantify the dependence of the distribution's width with respect to the DOI, we first studied an analytical model of the light-distribution and tested it by means of Monte Carlo (MC) simulations of the light transport inside the crystal. Further we present an inexpensive modification of the commonly used charge division circuit that allows analog and instantaneo…

PhysicsNuclear and High Energy PhysicsPhotomultiplierScintillationbusiness.industryDetectorMonte Carlo methodGamma rayCompton scatteringPhotodetectorProportional counterOpticsNuclear Energy and EngineeringElectrical and Electronic EngineeringbusinessIEEE Transactions on Nuclear Science
researchProduct

Extensive electrical model of large area silicon photomultipliers

2011

Abstract In this paper the full electrical model of silicon photomultipliers fabricated at STMicroelectronics Catania R&D clean room facilities is presented. An accurate investigation on both SiPM single microcell and entire SiPM structure to extrapolate all the electrical elements has been executed by means of dedicated characterizations carried out on appropriate layout structure. The electrical simulations results are compared to the experimental data showing a good fit and therefore verifying the accuracy of the proposed model. This model can be used to describe all the SiPMs with different sizes manufactured using the same technology. Moreover, starting from this extensive electrical m…

PhysicsNuclear and High Energy PhysicsPhotomultiplierSiliconElectrical modelchemistry.chemical_elementElectrical elementApplication softwarecomputer.software_genreSilicon photomultiplierchemistryElectronic engineeringMicrocellInstrumentationcomputerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Front-End Electronics for the KAOS Spectrometer at MAMI

2009

A new front-end electronics system has been developed for the electron arm tracking detectors in the Kaos spectrometer at the Mainz microtron MAMI. The signals of multi-anode photomultipliers are collected by 96-channel front-end boards, digitized by double-threshold discriminators and the signal time is picked up by F1 TDC chips. The system was designed to process more than 4,000 channels and to cope with the high electron flux in the spectrometer and the high count rate requirement of the detectors. A subset of 288 channels was installed and successfully used in the 2008 data taking period of the Kaos spectrometer.

PhysicsNuclear and High Energy PhysicsPhotomultiplierSpectrometerbusiness.industryDetectorElectrical engineeringTracking (particle physics)Signaldouble-threshold discriminator; front-end electronics; multi-anode photomultiplier; microtronNuclear Energy and EngineeringNuclear electronicsElectrical and Electronic EngineeringKAOSbusinessMicrotronIEEE Transactions on Nuclear Science
researchProduct

In-beam tests of scintillating fibre detectors at MAMI and at GSI

2008

The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The var…

PhysicsNuclear and High Energy PhysicsPhotomultiplierSpectrometerbusiness.industryDetectorFOS: Physical sciencesCharged particleParticle detectorNuclear physicsFull width at half maximumOpticsNuclear Experiment (nucl-ex)businessInstrumentationMicrotronNuclear ExperimentBeam (structure)
researchProduct

Design and status of COMPASS FAST-RICH

2006

In the context of the upgrade of COMPASS RICH-1, we are developing a fast photodetection system for RICH counters, based on UV extended Multi-Anode PhotoMultiplier Tubes (MAPMT) and a custom, low dead-time electronic readout system. Photons are concentrated on the MAPMT photocathode by an optical system that preserves the position information. The ratio between the collection and the photosensitive surfaces is ∼7.5 in our design, larger than in previous applications. A new front-end electronics, based on a modified version of the MAD4 discriminator chip, is being realized to digitize the MAPMT signals. We report about the design of the photodetection system and of the associated electronic …

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryContext (language use)PhotodetectionChipPhotocathodeOpticsUpgradeCompassElectronicsbusinessInstrumentation
researchProduct

The atmospheric nightglow in the 300– wavelength

2002

Abstract The balloon-borne experiment, named BAckground BYpass (BABY) belongs to a wider program that has as its final goal the detection and study of high-energy cosmic rays from space (satellite, Space Station). An information of fundamental importance for this class of projects concerns the nighttime background light. The instrument designed to detect fluorescence photons is basically composed of two collimated photomultipliers: a single photon-counting PMT and a charge integration PMT. We briefly report the details of the design, operation and performance of the detector, which was designed and completely built at the IFCAI–CNR Institute in Palermo. Preliminary analysis and results of t…

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryDetectorAirglowSpace ShuttleCosmic rayParticle detectorCollimated lightOpticsSatellitebusinessInstrumentationRemote sensingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Read-out electronics for fast photon detection with COMPASS RICH-1

2008

A new read-out electronics system has been developed for the fast photon detection of the central region of the COMPASS RICH-1. The project is based on multi-anode photomultipliers read out by the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1 TDC chip characterised by high time resolution. The system has been designed taking into account the high photon flux in the central region of the detector and the high rate requirement of the COMPASS experiment. The system is described in detail together with the measured performances. The new electronics system has been installed and used for the 2006 data taking; it entirely fulfils the expected performances.

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryDetectorChipParticle identificationOpticsCompassCOMPASS experimentElectronicsbusinessInstrumentationPhoton detection
researchProduct

Position sensitive scintillator based detector improvements by means of an integrated front-end

2009

PESIC is an integrated front-end for multianode photomultiplier based nuclear imaging devices. Its architecture has been designed to improve position sensitive detectors behavior by equalizing its response over its whole area. Its preamplying stage introduces two main benefits: digitally programmable gain adjustment for every photomultiplier output, and isolation from other front-end electronics by means of current buffers. This last feature allows to use different types of photomultipliers and optimizes front-end deadtime, reducing impact position dependent output delay. PESIC also includes an indirect measurement of the depth of interaction of the gamma ray inside the scintillator crystal…

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryDetectorEqualization (audio)ScintillatorFront and back endsOpticsApplication-specific integrated circuitCalibrationElectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment