Search results for "NOISE"
showing 10 items of 1375 documents
Phase-shifting of correlation fringes created by image processing as an alternative to improve digital shearography
2016
Abstract The adoption of digital speckle pattern shearing interferometry, or speckle shearography, is well known in many areas when one needs to measure micro-displacements in-plane and out of the plane in biological and non-biological objects; it is based on the Michelson's Interferometer with the use of a piezoelectric transducer (PZT) in order to provide the phase-shift of the fringes and then to improve the quality of the final image. The creation of the shifting images using a PZT, despite its widespread use, has some drawbacks or limitations, such as the cost of the apparatus, the difficulties in applying the same displacement in the mirror repeated times, and when the phase-shift can…
Functional statistics based method for the evaluation of the registration of sequences of 3D perfusion MR images
2011
Accurate registration of medical images is a necessary task for several important diagnosis techniques. Nevertheless, it is a difficult challenge due to movement of the patient, deformations, noise in the signal, etc. Besides, evaluation of the quality of the performed registration is also troublesome, specially when no golden pattern (true result) is available and/or when the signal values may have changed between successive images/volumes to be registered.
Adaptive Threshold, Wavelet and Hilbert Transform for QRS Detection in Electrocardiogram Signals
2017
This paper combines Hilbert and Wavelet transforms and an adaptive threshold technique to detect the QRS complex of electrocardiogram signals. The method is performed in a window framework. First, the Wavelet transform is applied to the ECG signal to remove noise. Next, the Hilbert transform is applied to detect dominant peak points in the signal. Finally, the adaptive threshold technique is applied to detect R-peaks, Q, and S points. The performance of the algorithm is evaluated against the MIT-BIH arrhythmia database, and the numerical results indicated significant detection accuracy.
Multilevel system optimisation via nonlinearity management
2006
Nonlinearity management is explored as a multilevel tool to obtain maximum transmission reach in a WDM system. A technique for the fast calculation of the optimal dispersion pre-compensation in systems with distributed amplification is proposed.
Exploring FPGA Based Lock-in Techniques for Brain Monitoring Applications
2017
Functional Near Infrared Spectroscopy (fNIRS) systems for e-health applications usually suffer of poor signal detection mainly due to a low end-to-end signal to noise ratio of the electronics chain. Lock-In Amplifiers (LIA) historically represent a powerful technique helping to improve performances in such circumstances. In this work it has been designed and implemented a digital LIA system, based on a Zynq® Field Programmable Gate Array (FPGA), trying to explore if this technique might improve fNIRS system performances. More broadly, FPGA based solution flexibility has been investigated, with particular emphasis applied to digital filter parameters, needed in the digital LIA, and i…
Line reconstruction using prior knowledge in single non-central view
2016
International audience; Line projections in non-central systems contain more geometric information than in central systems. The four degrees of freedom of the 3D line are mapped to the line-image and the 3D line can be theoretically recovered from 4 projecting rays (i.e. line-image points) from a single non-central view. In practice, extraction of line-images is consid- erably more difficult and the resulting reconstruction is imprecise and sensitive to noise. In this paper we present a minimal solution to recover the geometry of the 3D line from only three line-image points when the line is parallel to a given plane. A second minimal solution allows to recover the 3D line from two points w…
Subpixel determination of imperfect circles characteristics
2008
This article deals with the problem of the determination of characteristics of imperfect circular objects in discrete images, namely the radius and center coordinates. To limit distortion, a multi-level method based on active contours was developed. Its originality is to furnish a set of geometric envelopes in one pass, with a correspondence between grayscale and a regularity scale. The adequacy of this approach was tested with several methods, among them is the Radon-based method. More particularly, this study indicates the relevance of the use of active contours combined with a Radon transform-based method which was improved using a fitting considering the discrete implementation of the R…
Fast Implementation of Double-coupled Nonnegative Canonical Polyadic Decomposition
2019
Real-world data exhibiting high order/dimensionality and various couplings are linked to each other since they share some common characteristics. Coupled tensor decomposition has become a popular technique for group analysis in recent years, especially for simultaneous analysis of multi-block tensor data with common information. To address the multiblock tensor data, we propose a fast double-coupled nonnegative Canonical Polyadic Decomposition (FDC-NCPD) algorithm in this study, based on the linked CP tensor decomposition (LCPTD) model and fast Hierarchical Alternating Least Squares (Fast-HALS) algorithm. The proposed FDCNCPD algorithm enables simultaneous extraction of common components, i…
Restoration and Enhancement of Historical Stereo Photos Through Optical Flow
2021
Restoration of digital visual media acquired from repositories of historical photographic and cinematographic material is of key importance for the preservation, study and transmission of the legacy of past cultures to the coming generations. In this paper, a fully automatic approach to the digital restoration of historical stereo photographs is proposed. The approach exploits the content redundancy in stereo pairs for detecting and fixing scratches, dust, dirt spots and many other defects in the original images, as well as improving contrast and illumination. This is done by estimating the optical flow between the images, and using it to register one view onto the other both geometrically …
Peer to Peer Equation Augmentation for an Altitude Aided GNSS Receiver
2010
This paper considers the possibility to integrate external altitude measurements with a Kalman based Global Navigation Satellite System (GNSS) receiver in a peer to peer scenario. The performance of such a system is investigated for different characteristics of the aiding measurement and for different degree of trust of the receiver upon the aiding measurement. The aiding measurement is obtained starting from the altitude measurements that the other peers in the network send to the aided user. The experiments highlight the need for a parameter that points out the effectiveness and the consistency of the computed aiding measurement. To this purpose, a reliability index is proposed, on the ba…