Search results for "NPE"

showing 10 items of 121 documents

Impact of emergency medical helicopter transport directly to a university hospital trauma center on mortality of severe blunt trauma patients until d…

2012

International audience; IntroductionThe benefits of transporting severely injured patients by helicopter remain controversial. This study aimed to analyze the impact on mortality of helicopter compared to ground transport directly from the scene to a University hospital trauma center.MethodsThe French Intensive Care Research for Severe Trauma cohort study enrolled 2,703 patients with severe blunt trauma requiring admission to University hospital intensive care units within 72 hours. Pre-hospital and hospital clinical data, including the mode of transport, (helicopter (HMICU) versus ground (GMICU), both with medical teams), were recorded. The analysis was restricted to patients admitted dire…

AdultMalemedicine.medical_specialty[SDV.MHEP.PHY] Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO][SDV]Life Sciences [q-bio]Wounds NonpenetratingCritical Care and Intensive Care MedicineCohort StudiesHospitals Universitypre-hospital care03 medical and health sciencesYoung Adult0302 clinical medicineInjury Severity ScoreTrauma CentersInterquartile rangeIntensive care[SDV.MHEP.PHY]Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO]MedicineHumans030212 general & internal medicineProspective StudiesProspective cohort study[ SDV ] Life Sciences [q-bio]business.industry[ SDV.MHEP.PHY ] Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO]ResearchTrauma center030208 emergency & critical care medicineOdds ratioAir AmbulancesMiddle AgedmortalityPatient DischargeTransportation of PatientsBlunt traumahelicopter transportEmergency medicineInjury Severity ScoreFemalebusinesssevere trauma patientsCohort study
researchProduct

Impact of whole-body computed tomography on mortality and surgical management of severe blunt trauma

2012

International audience; IntroductionThe mortality benefit of whole-body computed tomography (CT) in early trauma management remains controversial and poorly understood. The objective of this study was to assess the impact of whole-body CT compared with selective CT on mortality and management of patients with severe blunt trauma.MethodsThe FIRST (French Intensive care Recorded in Severe Trauma) study is a multicenter cohort study on consecutive patients with severe blunt trauma requiring admission to intensive care units from university hospital trauma centers within the first 72 hours. Initial data were combined to construct a propensity score to receive whole-body CT and selective CT used…

AdultMalemedicine.medical_specialty[SDV.MHEP.PHY] Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO][SHS.INFO]Humanities and Social Sciences/Library and information sciencesCritical Care and Intensive Care MedicineWounds Nonpenetrating[SHS.INFO] Humanities and Social Sciences/Library and information sciencesCohort Studies03 medical and health sciencesYoung Adult0302 clinical medicineIntensive care[ SHS.INFO ] Humanities and Social Sciences/Library and information sciences[SDV.MHEP.PHY]Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO]MedicineHumans030212 general & internal medicineProspective StudiesYoung adultMortalityProspective cohort studyTrauma Severity Indicesblunt trauma[ SDV.MHEP.PHY ] Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO]business.industryMortality rateResearchDisease Management030208 emergency & critical care medicineMiddle Aged3. Good healthSurgeryBlunt traumaPropensity score matchingInjury Severity ScoreFemalebusinessTomography X-Ray ComputedCohort study
researchProduct

Cardiac rupture caused by traffic accident: Case reports and a literature review.

2018

The commonest cause of blunt cardiac injuries is from traffic accidents followed by violent falls, sport activities, accidents or a fight but rupture of the heart is rare and lethal. The precise incidence of cardiac injury after a blunt chest trauma is unknown as rates vary greatly in the literature from between 7% and 76% of cases. Autopsy studies have shown that the right ventricle is the most frequently ruptured, followed by the left ventricle, right atrium, intraventricular septum, left atrium and interatrial septum with decreasing frequency. Post-mortem imaging is a rapidly advancing field of post-mortem investigations of trauma victims. The available literature dealing with the compa…

AdultMalemedicine.medical_specialtyblunt chest traumaHeart RuptureHeart RupturePoison controlAutopsyWounds NonpenetratingForensic pathology03 medical and health sciences0302 clinical medicineBluntSettore MED/43 - Medicina LegalemedicineHumans030216 legal & forensic medicinebusiness.industryCardiac RuptureAccidents Traffic030208 emergency & critical care medicineGeneral MedicineMiddle Agedcardiac rupturemedicine.anatomical_structureVentriclecomputed tomography post-mortemBody regionFemaleRadiologyForensic pathology; blunt chest trauma; cardiac rupture; computed tomography post-mortembusinessTomography X-Ray ComputedInteratrial septumThe Medico-legal journal
researchProduct

Virtopsy and Living Individuals Evaluation Using Computed Tomography in Forensic Diagnostic Imaging

2019

The applications of forensic radiology involve both Virtopsy both studies on living people - to demonstrate bone age, search for foreign bodies, such as voluntary injection of drug ovules or surgical sponges accidentally forgotten, to assess gunshot wounds, to evaluate injuries by road accidents, and cases of violence or abuse (both in adults and in children). Computed tomography is the most used imaging tool used in forensic pathology and its indications are mainly focused on cases of unnatural deaths or when a crime is suspected. It is preferred over the standard autopsy in selected cases, such as in putrefied, carbonized or badly damaged bodies; or as a preliminary evaluation in mass dis…

Adultmedicine.medical_specialtyForensic pathologyAutopsyComputed tomographyWounds Nonpenetrating030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineVirtopsyAge Determination by SkeletonMedical imagingHumansMedicineRadiology Nuclear Medicine and imagingChildmedicine.diagnostic_testbusiness.industryGeneral surgerySurgical SpongesForensic MedicineForeign BodiesForensic scienceForensic radiologyWounds GunshotAutopsyTomography X-Ray Computedbusiness030217 neurology & neurosurgerySeminars in Ultrasound, CT and MRI
researchProduct

An efficient functional magnetic resonance imaging data reduction strategy using neighborhood preserving embedding algorithm

2021

High dimensionality data have become common in neuroimaging fields, especially group-level functional magnetic resonance imaging (fMRI) datasets. fMRI connectivity analysis is a widely used, powerful technique for studying functional brain networks to probe underlying mechanisms of brain function and neuropsychological disorders. However, data-driven technique like independent components analysis (ICA), can yield unstable and inconsistent results, confounding the true effects of interest and hindering the understanding of brain functionality and connectivity. A key contributing factor to this instability is the information loss that occurs during fMRI data reduction. Data reduction of high …

Brain MappingPrincipal Component AnalysisRadiological and Ultrasound TechnologysignaalinkäsittelyfMRIBrainMagnetic Resonance Imagingtoiminnallinen magneettikuvausNeurologyHumansRadiology Nuclear Medicine and imagingNeurology (clinical)ICAAnatomyAlgorithmsNPEdimensionality reduction
researchProduct

Transverse-momentum-dependent Multiplicities of Charged Hadrons in Muon-Deuteron Deep Inelastic Scattering

2017

A semi-inclusive measurement of charged hadron multiplicities in deep inelastic muon scattering off an isoscalar target was performed using data collected by the COMPASS Collaboration at CERN. The following kinematic domain is covered by the data: photon virtuality $Q^{2}>1$ (GeV/$c$)$^2$, invariant mass of the hadronic system $W > 5$ GeV/$c^2$, Bjorken scaling variable in the range $0.003 < x < 0.4$, fraction of the virtual photon energy carried by the hadron in the range $0.2 < z < 0.8$, square of the hadron transverse momentum with respect to the virtual photon direction in the range 0.02 (GeV/$c)^2 < P_{\rm{hT}}^{2} < 3$ (GeV/$c$)$^2$. The multiplicities are pres…

CERN LabComputerSystemsOrganization_COMPUTERSYSTEMIMPLEMENTATIONMULTIPLICITIESdimension: 3PT DEPENDENTComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONFOS: Physical sciencesComputerApplications_COMPUTERSINOTHERSYSTEMStarget: isoscalarmuon deuteron: deep inelastic scattering[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]nucl-extransverse momentum dependencehadron: transverse momentumSIDISCOMPASSGeneralLiterature_MISCELLANEOUSHigh Energy Physics - Experimentscaling: BjorkenSubatomär fysikcharged particle: multiplicityHigh Energy Physics - Experiment (hep-ex)[ PHYS.HEXP ] Physics [physics]/High Energy Physics - Experiment [hep-ex]mass: hadronicSubatomic Physics[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Nuclear Physics - Experiment[ PHYS.NEXP ] Physics [physics]/Nuclear Experiment [nucl-ex]Nuclear Experiment (nucl-ex)quantum chromodynamics: perturbation theoryNuclear ExperimentNuclear ExperimentDIShep-exhadron: multiplicityeffect: nonperturbativeperturbation theory: higher-orderCERN SPSphoton: energysemi-inclusive reactionComputingMethodologies_PATTERNRECOGNITIONkinematicsDIS; SIDIS; MULTIPLICITIES; PT DEPENDENTHigh Energy Physics::ExperimentParticle Physics - Experimentexperimental resultsphoton: virtual
researchProduct

Spectral function for overoccupied gluodynamics from real-time lattice simulations

2018

We study the spectral properties of a highly occupied non-Abelian non-equilibrium plasma appearing ubiquitously in weak coupling descriptions of QCD matter. The spectral function of this far-from-equilibrium plasma is measured by employing linear response theory in classical-statistical real-time lattice Yang-Mills simulations. We establish the existence of transversely and longitudinally polarized quasiparticles and obtain their dispersion relations, effective mass, plasmon frequency, damping rate and further structures in the spectral and statistical functions. Our new method can be interpreted as a non-perturbative generalization of hard thermal loop (HTL) effective theory. We see indica…

CLASSICAL APPROXIMATIONNuclear Theorynucl-thquark-gluon plasmahep-latFOS: Physical sciencesHEAVY-ION COLLISIONShiukkasfysiikka114 Physical sciences01 natural sciencesNuclear Theory (nucl-th)High Energy Physics - LatticeHigh Energy Physics - Phenomenology (hep-ph)Lattice (order)0103 physical sciencesquantum chromodynamicsQCD PLASMA INSTABILITIESStatistical physicsGauge theorynonperturbative effects in field theory010306 general physicsHARD THERMAL LOOPSParticle Physics - PhenomenologyPhysicsQuantum chromodynamicsta114010308 nuclear & particles physicsHigh Energy Physics - Lattice (hep-lat)kvarkki-gluoniplasmafinite temperature field theorylattice field theoryISOTROPIZATIONParticle Physics - Latticehep-ph16. Peace & justiceFIELD-THEORYGluonHigh Energy Physics - PhenomenologyNuclear Physics - TheoryQuark–gluon plasmaHIGH-TEMPERATUREGAUGE-THEORIESQuasiparticleSpectral functionkvanttikenttäteoriaStatistical correlationrelativistic heavy-ion collisions
researchProduct

Effects of femtosecond laser and other surface treatments on the bond strength of metallic and ceramic orthodontic brackets to zirconia.

2017

Femtosecond laser has been proposed as a method for conditioning zirconia surfaces to boost bond strength. However, metallic or ceramic bracket bonding to femtosecond lasertreated zirconia surfaces has not been tested. This study compared the effects of four conditioning techniques, including femtosecond laser irradiation, on shear bond strength (SBS) of metallic and ceramic brackets to zirconia.Three hundred zirconia plates were divided into five groups: 1) control (C); 2) sandblasting (APA); 3) silica coating and silane (SC); 4) femtosecond laser (FS); 5) sandblasting followed by femtosecond laser (APA+SC). A thermal imaging camera measured temperature changes in the zirconia during irrad…

CeramicsScanning electron microscopeOrthodontic Bracketslcsh:MedicineTissue AdhesionsCoating Materials030207 dermatology & venereal diseases0302 clinical medicineMedicine and Health SciencesSilaneElectron MicroscopyCubic zirconiaCeramicZirconium oxideComposite materiallcsh:ScienceMicroscopyMultidisciplinaryBond strengthBracketTemperatureOptical EquipmentMetalsvisual_artPhysical SciencesFemtosecondvisual_art.visual_art_mediumEngineering and TechnologyScanning Electron MicroscopyShear StrengthResearch ArticleMaterials scienceMaterials by StructureMaterials ScienceOral MedicineEquipmentOrthodonticsResearch and Analysis MethodsENPEP gene03 medical and health sciencesCoatingsAdhesivesShear strengthMaterials by AttributeUniversal testing machineSurface TreatmentsLaserslcsh:R030206 dentistryManufacturing ProcessesMicroscopy Electron Scanninglcsh:QZirconiumPLoS ONE
researchProduct

Why Do Chemically Similar Pharmaceutical Molecules Crystallize in Different Structures: A Case of Droperidol and Benperidol

2016

A detailed study of molecular conformation and intermolecular interactions in the experimental crystal structures and general trends observed in the Cambridge Structural Database as well as theoretical calculations were performed to identify the reason for the formation of different crystal structures of two chemically very similar pharmaceutical molecules benperidol and droperidol. The most important difference between both molecules was the weak intermolecular interactions formed by the central ring which therefore was responsible for the formation of different crystal structures. Cross-seeding experiments were performed to check the possibility for the formation of mutually isostructural…

ChemistryIntermolecular force02 engineering and technologyGeneral ChemistryCrystal structure010402 general chemistry021001 nanoscience & nanotechnologyCondensed Matter PhysicsRing (chemistry)01 natural sciencesMolecular conformation0104 chemical sciencesBenperidolCrystallographymedicineMoleculeGeneral Materials ScienceIsostructural0210 nano-technologyDroperidolmedicine.drugCrystal Growth & Design
researchProduct

Determination of benperidol and its reduced metabolite in human plasma by high-performance liquid chromatography and electrochemical detection.

1991

An isocratic high-performance liquid chromatographic method with electrochemical detection for the quantification of benperidol and its suggested reduced metabolite TVX Q 5402 in human plasma is described. The method included a two-step solid-phase extraction on reversed-phase and cation-exchange material, followed by separation on a cyanopropyl silica gel column (5 microns; 250 mm x 4.6 mm I.D.). The eluent was 0.15 M acetate buffer (pH 4.7) containing 25% acetonitrile (w/w). Spiperone served as internal standard. The inclusion of the cation-exchange step provided sample purity higher than those achieved with other methods. After extraction of 1 ml of plasma, concentrations as low as 0.5 n…

ChromatographySilica gelMetaboliteBenperidolExtraction (chemistry)General ChemistryHigh-performance liquid chromatographychemistry.chemical_compoundBenperidolColumn chromatographychemistryBlood plasmamedicineElectrochemistryHumansAcetonitrileChromatography High Pressure Liquidmedicine.drugJournal of chromatography
researchProduct