Search results for "NUCLEAR MEDICINE"

showing 10 items of 3573 documents

Complexation des acides aminés basiques arginine, histidine et lysine avec l’ADN plasmidique en solution aqueuse : participation à la capture de radi…

2016

L’environnement chimique de l’ADN en situation biologique est complexe notam-ment en raison de la presence d’histones, proteines nucleaires, associees en quantite approximativement egales a l’ADN pour former la chromatine. Les histones possedent de nombreux radicaux basiques arginine et lysine charges positivement et dont la majorite se trouve sur les chaines emergentes, l’ADN presente quant a lui des charges negatives sur ses groupements phosphates localises tout au long de la double helice. Dans cette etude, la complexite de la structure de la chromatine nucleaire est dans un premier temps mimee en solution aqueuse par la formation de complexes entre un ADN plasmidique sonde et les trois …

03 medical and health sciences0302 clinical medicineChemistryPhysicsQC1-999030220 oncology & carcinogenesisMolecular biology030218 nuclear medicine & medical imagingEPJ Web of Conferences
researchProduct

Morfofisiología del diafragma torácico en las medicinas china y occidental

2016

Resumen Las autoras creen que el analisis comparativo de diversos temas entre la medicina china y la occidental supone una aportacion al progresivo —y deseado— avance hacia la mutua comprension y sinergia entre ambas disciplinas. La descripcion occidental del diafragma toracico sugiere ciertas lineas de confluencia respecto al enfoque chino: anatomicamente aportan sugerentes paralelismos las referencias de insercion muscular e inervacion del diafragma, asi como su biodinamica respiratoria, elementos coincidentes con la posicion de diversos puntos de acupuntura toracicos que presentan, ademas, posibles semejanzas en sus funciones fisiologicas reguladoras a diversos niveles, con las que la me…

03 medical and health sciences0302 clinical medicineComplementary and alternative medicine030220 oncology & carcinogenesis030218 nuclear medicine & medical imagingRevista Internacional de Acupuntura
researchProduct

Development of a fast characterization setup for radionuclide generators demonstrated by a 227Ac-based generator

2021

Abstract The development of a setup for a fast online characterization of radionuclide generators is reported. A generator utilizing the mother nuclide 227Ac sorbed on a cation exchange resin is continuously eluted by using a peristaltic pump. To allow continuous and pulse-free elution of a large volume over extended time periods a 3D-printed interface designed to remove pressure-oscillations induced by the pump was placed between pump and generator column to ensure undisturbed generator elution. The eluate of the generator is passed through a 3D printed flow cell placed inside a borehole Na(Tl)-scintillation detector for high counting efficiency. Alternatively, a HPGe detector suitable for…

03 medical and health sciences0302 clinical medicineGenerator (computer programming)ChemistryNuclear engineeringPhysical and Theoretical ChemistryRadionuclide Generator010403 inorganic & nuclear chemistry01 natural sciences030218 nuclear medicine & medical imaging0104 chemical sciencesCharacterization (materials science)Radiochimica Acta
researchProduct

Tratamiento endoscópico de una membrana duodenal fenestrada mediante dilatación

2018

03 medical and health sciences0302 clinical medicineHepatologybusiness.industry030220 oncology & carcinogenesisGastroenterologyMedicine030211 gastroenterology & hepatologyNuclear medicinebusinessGastroenterología y Hepatología
researchProduct

Simple eddy current compensation by additional gradient pulses

2018

03 medical and health sciences0302 clinical medicineMaterials scienceSimple (abstract algebra)Control theorylawEddy current030217 neurology & neurosurgerySpectroscopy030218 nuclear medicine & medical imagingCompensation (engineering)law.inventionConcepts in Magnetic Resonance Part A
researchProduct

Electronic processes in doped ZnO nanopowders

2019

The financial support of research grants ERA.NET RUS_ST20170-051 and SFERA II project “Transnational Access activities” (EU 7th Framework Programme Grant Agreement N312643). This work was partly supported by the Russian Foundation for Basic Research, project no. 18-52-76002.

03 medical and health sciences0302 clinical medicineMaterials sciencebusiness.industryDoping:NATURAL SCIENCES:Physics [Research Subject Categories]Optoelectronics02 engineering and technology021001 nanoscience & nanotechnology0210 nano-technologybusiness030218 nuclear medicine & medical imagingIOP Conference Series: Materials Science and Engineering
researchProduct

Estimation of Location and Activation Time of Purkinje Myocardial Junctions from Sparse and Noisy Endocardial Electrical Samples

2017

The activation of the myocardial muscle is triggered by Purkinje-myocardial junctions (PMJs), which are the terminal sites of the specialised cardiac conduction system (CCS). Obtaining the location of the PMJs and other sources of endocardial ectopic activity would be desirable for building computer models of cardiac electrophysiology and planning ablation interventions. We present a method to estimate the location and activation times of endocardial electrical sources in a 3D model of the ventricles. The algorithm requires a set of discrete electrical samples on the endocardium, which can include errors in location and activation time. The estimated sources are properly placed with a locat…

03 medical and health sciences0302 clinical medicineObservational errorTerminal (electronics)Computer scienceCardiac electrophysiologyTime error3d model030204 cardiovascular system & hematologyElectrical conduction system of the heartEndocardium030218 nuclear medicine & medical imagingBiomedical engineeringComputing in Cardiology Conference (CinC)
researchProduct

Reconstruction faciale complexe sur mesure : un cas de remplacement total de l’articulation temporo-mandibulaire, de l’arcade zygomatique et du zygoma

2017

Resume Introduction Le remplacement total prothetique de l’articulation temporo-mandibulaire (ATM) est devenu une intervention courante, mais ce remplacement prothetique se cantonne habituellement a l’ATM. Nous presentons le cas d’une reconstruction prothetique complexe sur mesure etendue l’articulation et les structures osseuses voisines. Observation Un patient de 57 ans, multi-opere pour une dysplasie fibreuse crânio-faciale droite, presentait une recidive d’ankylose de l’ATM droite et une perte de substance osseuse latero-faciale droite complexe. Nous sommes intervenus pour proceder a une reconstruction incluant l’ATM, l’arcade zygomatique et le zygoma a l’aide d’une prothese sur mesure …

03 medical and health sciences0302 clinical medicineOtorhinolaryngologybusiness.industryMedicineSurgery030206 dentistryOral Surgery030223 otorhinolaryngologybusinessNuclear medicineJournal of Stomatology, Oral and Maxillofacial Surgery
researchProduct

Anatomia e patologia del labirinto membranoso studio con sequenze RM sensibili al flusso

1994

Nonostante i deludenti esordi nella valutazione delle strutture labirintiche costituenti l'orecchio interno, la risonanza magnetica costituisce oggi, grazie anche al miglioramento dell'hardware e del software disponibili, una modalità diagnostica di grande efficacia non solo nell'analisi della patologia espansiva o infiammatoria coinvolgente il VII ed VIII nervo cranico, ma anche nella valutazione delle alterazioni patologiche del segnale endolabirintico in rapporto a focolai emorragici o, come recentemente dimostrato mediante uso di Gd-DTPA, nell'analisi delle alterazioni a carico della capsula oticanella fase spongiotica dell'otosclerosi. Tuttavia, lo scarso contrasto esistente tra liqui…

03 medical and health sciences0302 clinical medicineRadiological and Ultrasound Technologymedia_common.quotation_subjectRadiology Nuclear Medicine and imagingNeurology (clinical)ArtHumanities030217 neurology & neurosurgery030218 nuclear medicine & medical imagingmedia_commonRivista di Neuroradiologia
researchProduct

Análisis estructural cuantitativo del hueso alveolar trabecular de la mandíbula en tomografía computarizada multidetector: diferencias por tipo y est…

2019

Resumen Antecedentes y objetivo Existe una carencia de metricas cuantitativas de la calidad del hueso trabecular alveolar, factor determinante en implantologia. El objetivo de este estudio es desarrollar una metodologia con tomografia computarizada multidetector para objetivar la calidad del hueso trabecular y establecer diferencias entre los distintos tipos y el estado de las piezas dentarias mediante procesado de imagenes y analisis estructural. Materiales y metodos Se analizan 20 pacientes con exploracion de tomografia computarizada multidetector dental para la valoracion del hueso mandibular y posiciones dentales. El analisis de las imagenes incluyo la segmentacion automatica de la mand…

03 medical and health sciences0302 clinical medicineRadiology Nuclear Medicine and imaging030206 dentistry030218 nuclear medicine & medical imagingRadiología
researchProduct