Search results for "Non-invasive"

showing 10 items of 82 documents

Predictors of non-invasive ventilation tolerance in amyotrophic lateral sclerosis

2011

Abstract Background The most frequent cause of death in patients with Amyotrophic Lateral Sclerosis (ALS) is respiratory failure. Recently, it has been shown that non-invasive ventilation improves survival and quality of life in ALS patients with respiratory failure, but little is known about predictors of non-invasive ventilation adaptation and tolerance. In this study we evaluated the effect of a comprehensive information about non-invasive ventilation use and a prolonged and intensive monitoring on tolerance to this palliative care. Methods We prospectively monitored all consecutive ALS patients with chronic respiratory failure and indication to non-invasive ventilation between January 2…

MaleALS Chronic respiratory failure Tolerance to non-invasive ventilation Bulbar impairment POSITIVE-PRESSURE VENTILATION QUALITY-OF-LIFE PRACTICE PARAMETER CARE MANAGEMENT STANDARDS BIPAPmedicine.medical_specialtyPalliative carePatientsTolerance to non-invasive ventilationBody Mass IndexQuality of lifeQUALITY-OF-LIFEPRACTICE PARAMETERMANAGEMENTHumansMedicineDementiaChronic respiratory failureOximetryProspective StudiesAmyotrophic lateral sclerosisIntensive care medicineBIPAPAgedCause of deathVentilators Mechanicaltolerancebusiness.industryAmyotrophic Lateral SclerosisRespiratory diseaseSialorrheaCAREMiddle Agedmedicine.diseaseRespiration ArtificialBulbar impairment POSITIVE-PRESSURE VENTILATIONCaregiversNeurologyRespiratory failureSpirometryChronic DiseaseNIVEmergency medicineBreathingFemaleSettore MED/26 - NeurologiaNeurology (clinical)Blood Gas AnalysisALSRespiratory InsufficiencybusinessSTANDARDSJournal of the Neurological Sciences
researchProduct

Controlled attenuation parameter and alcoholic hepatic steatosis: Diagnostic accuracy and role of alcohol detoxification.

2018

Background & Aims: Controlled attenuation parameter (CAP) is a novel non-invasive measure of hepatic steatosis, but it has not been evaluated in alcoholic liver disease. Therefore, we aimed to validate CAP for the assessment of biopsy-verified alcoholic steatosis and to study the effect of alcohol detoxification on CAP. Methods: This was a cross-sectional biopsy-controlled diagnostic study in four European liver centres. Consecutive alcohol-overusing patients underwent concomitant CAP, regular ultrasound, and liver biopsy. In addition, we measured CAP before and after admission for detoxification in a separate single-centre cohort. Results: A total of 562 patients were included in the s…

MaleAlcoholic liver diseasemedicine.medical_treatmentBiopsyGastroenterologyCohort StudiesSensitivity0302 clinical medicineInterquartile rangeRisk FactorsAlcohol detoxificationNon-invasiveSteatohepatitisUltrasonography2. Zero hungerMetabolic Syndromemedicine.diagnostic_testAlcohol AbstinenceFatty liverAlcohol detoxificationDiagnostic testMiddle Aged3. Good healthAlcoholismLiver030220 oncology & carcinogenesisLiver biopsyControlled attenuation parameterSpecificityElasticity Imaging Techniques030211 gastroenterology & hepatologyFemaleFatty Liver AlcoholicAdultmedicine.medical_specialty03 medical and health sciencesPredictive Value of TestsFatty liverInternal medicinemedicineHumansFibroScanHepatologybusiness.industryAlcoholic liver diseasemedicine.diseaseCross-Sectional StudiesConcomitantSteatohepatitisSteatosisbusinessJournal of hepatology
researchProduct

Influence of landscape composition and diversity on contaminant flux in terrestrial food webs: a case study of trace metal transfer to European black…

2012

13 pages; International audience; Although understanding the influence of the spatial arrangement of habitats and interacting communities on the processes of pollutant flux and impacts is critical for exposure and risk assessment, to date few studies have been devoted to this emergent topic. We tested the hypothesis that landscape composition and diversity affect the transfer of trace metals to vertebrates. Bioaccumulation of Cd and Pb in blood and feathers of European blackbirds Turdus merula (n=138) was studied over a smelter-impacted area (Northern France). Landscape composition (type and occurrence of the different habitats) and diversity (number of different habitat types and the propo…

MaleInsecta010504 meteorology & atmospheric sciences[ SDV.TOX.ECO ] Life Sciences [q-bio]/Toxicology/Ecotoxicology010501 environmental sciencesWildlife01 natural sciencesSongbirdsFood chainSoilheavy-metalsTrace metalTissue DistributionWaste Management and DisposalEcologyEnvironmental exposurePollutionSoil contaminationhost factorsSpatial heterogeneityNon-invasive samplingHabitatDierecologieSpatial heterogeneityEnvironmental PollutantsFemale[SDV.TOX.ECO]Life Sciences [q-bio]/Toxicology/EcotoxicologyAnimal EcologyFranceCadmiumEnvironmental MonitoringEnvironmental EngineeringFood ChaincadmiumForagingEnvironmentAvian toxicologyecological risk-assessmentToxic chemicalsLandscape ecotoxicologysmall mammalsEnvironmental ChemistryAnimalsOligochaeta0105 earth and related environmental scienceslead[ SDE.BE ] Environmental Sciences/Biodiversity and EcologySpectrophotometry AtomicEnvironmental Exposure15. Life on landFeathersDietLead13. Climate actionexposurebirdssoil propertiesSpatial ecologyEnvironmental science[SDE.BE]Environmental Sciences/Biodiversity and EcologybioavailabilityThe Science of the total environment
researchProduct

N-BiPAP vs n-CPAP in term neonate with respiratory distress syndrome

2020

Abstract Background Non-invasive respiratory ventilation has greatly improved the evolution of respiratory distress in neonates, especially for preterm infants, but few studies have investigated the use of non-invasive ventilation (NIV) in term infants. It is useful for neonatologists and nurses to identify the optimal ventilation strategy in terms of effectiveness for this group of newborns. The aim of our study was to investigate what type of respiratory support between nasal Continuous Positive Airway Pressure (nCPAP) or nasal Biphasic Positive Airway Pressure (nBiPAP) is more effective in term neonates with RDS. Methods Our study was a retrospective observational study of 78 full term n…

MaleTerm infantsRespiratory distress syndromemedicine.medical_treatmentContinuous positive airway pressureVital signsBiphasic positive airway pressureNOBiphasic Positive Airway PressurePositive-Pressure Respiration03 medical and health sciences0302 clinical medicine030225 pediatricsmedicineHumansBiphasic positive airway pressure; Continuous positive airway pressure; Non-invasive ventilation; Respiratory distress syndrome; Term infants;Continuous positive airway pressureRespiratory systemFull TermRespiratory Distress Syndrome NewbornNoninvasive VentilationRespiratory distressbusiness.industryInfant NewbornObstetrics and Gynecologyrespiratory systemmedicine.diseaseBiphasic positive airway pressure; Continuous positive airway pressure; Non-invasive ventilation; Respiratory distress syndrome; Term infantsTerm infants.PneumothoraxAnesthesiaPediatrics Perinatology and Child HealthNon-invasive ventilationBreathingFemalebusiness030217 neurology & neurosurgeryEarly Human Development
researchProduct

Cardiac kinematic parameters computed from video of in situ beating heart

2017

AbstractMechanical function of the heart during open-chest cardiac surgery is exclusively monitored by echocardiographic techniques. However, little is known about local kinematics, particularly for the reperfused regions after ischemic events. We report a novel imaging modality, which extracts local and global kinematic parameters from videos of in situ beating hearts, displaying live video cardiograms of the contraction events. A custom algorithm tracked the movement of a video marker positioned ad hoc onto a selected area and analyzed, during the entire recording, the contraction trajectory, displacement, velocity, acceleration, kinetic energy and force. Moreover, global epicardial veloc…

Malemedicine.medical_specialtyBeating heartSystoleVideo RecordingCardiac kinematic parametersFOS: Physical sciencesMyocardial ReperfusionKinematics030204 cardiovascular system & hematologyQuantitative Biology - Quantitative MethodsArticleDisplacement (vector)03 medical and health sciencesAcceleration0302 clinical medicineDiastoleInternal medicinemedicineAnimalsHumansComputer Simulation030212 general & internal medicineCoronary Artery BypassAtrioventricular BlockTissues and Organs (q-bio.TO)Quantitative Methods (q-bio.QM)PhysicsLive videoMultidisciplinaryopen-chest cardiac surgeryReproducibility of ResultsQuantitative Biology - Tissues and OrgansHeartPhysics - Medical Physicscontact-free and non-invasive modeMyocardial ContractionBiomechanical PhenomenaRatsCardiac surgeryCardiac kinematic parameters open-chest cardiac surgery contact-free and non-invasive modemedicine.anatomical_structureParticle image velocimetryFOS: Biological sciencesCardiologyFemaleMedical Physics (physics.med-ph)RheologyArteryScientific Reports
researchProduct

Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography

2008

BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…

Malemedicine.medical_specialtymedicine.medical_treatmentCoronary AngiographySensitivity and SpecificityComputed tomography angiography Coronary stents Multidetector computed tomography Non-invasive imagingCoronary RestenosisRestenosisPredictive Value of TestsPositive predicative valueOcclusionmedicineHumanscardiovascular diseasesmedicine.diagnostic_testbusiness.industryStentGeneral MedicineMultislice computed tomographyMiddle Agedequipment and suppliesmedicine.diseaseCoronary Vesselssurgical procedures operativemedicine.anatomical_structureConcomitantAngiographyFemaleStentsRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessArteryJournal of Cardiovascular Medicine
researchProduct

"One-touch" voltammetry of microparticles for the identification of corrosion products in archaeological lead

2011

Voltammetry of microparticles is applied to the identification of lead corrosion products by means of an essentially non-invasive 'one-touch' technique based on the use of graphite pencil. This methodology permits the mechanical attachment of few nanograms of sample from the surface of lead archaeological artefacts to a paraffin-impregnated graphite electrode, which, upon immersion in aqueous electrolytes, provides distinctive voltammetric responses for litharge and cotunnite- anglesite-, cerusite-based corrosion products. The reported method is applied to the identification of corrosion products in archaeological lead pieces from different Iberian sites in Valencia (Spain). © 2011 WILEY-VC…

Materials scienceVoltammetry of microparticlesMetallurgyAqueous electrolyteArchaeologyAnalytical ChemistryCorrosionArchaeological leadAnglesitePINTURAElectrochemistryLithargeNon-invasive analysisGraphiteCorrosion productsVoltammetryGraphite electrode
researchProduct

Non-invasive investigation on pigments of the Aeolian Islands Neolithic pottery

2023

The Neolithic painted pottery, spread all over southern Italy, is considered as an important chronological indicator for the development of VI-V millennium BC prehistoric settlements and cultural traditions. The goal of this work is to contribute to the study of this ceramic class through the chemical characterization of some samples coming from the Aeolian Islands. 16 different sherds have been selected and the pigments preserved in their decorations analyzed via non-invasive techniques: Fiber Optical Reflectance Spectroscopy (FORS), X-ray Fluorescence (XRF), Raman Spectroscopy and Infrared Spectroscopy (FT-IR). The different pigments, some of which no longer clearly visible to the naked e…

Mechanics of MaterialsMechanical EngineeringNeolithic painted potteryNon-invasive measurementsHematiteGeneral Materials ScienceCondensed Matter PhysicsSettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni CulturaliSettore CHIM/02 - Chimica Fisica
researchProduct

Digitalized transcranial electrical stimulation: A consensus statement.

2022

Objective: Although relatively costly and non-scalable, non-invasive neuromodulation interventions are treatment alternatives for neuropsychiatric disorders. The recent developments of highly-deployable transcranial electric stimulation (tES) systems, combined with mobile-Health technologies, could be incorporated in digital trials to overcome methodological barriers and increase equity of access. The study aims are to discuss the implementation of tES digital trials by performing a systematic scoping review and strategic process mapping, evaluate methodological aspects of tES digital trial designs, and provide Delphi-based recommendations for implementing digital trials using tES.Methods: …

Mobile HealthConsensusSettore M-PSI/02 - PSICOBIOLOGIA E PSICOLOGIA FISIOLOGICAClinical psychologymethods [Transcranial Direct Current Stimulation]Transcranial Direct Current StimulationSensory SystemsElectric StimulationTelemedicinePsychiatry and Mental healthNeurologyPhysiology (medical)Delphi panelSystematic reviewHumansNon-invasive neuromodulationNeurology (clinical)ddc:610Digital healthClinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
researchProduct

Determining a healthy reference range and factors potentially influencing PRO-C3 – A biomarker of liver fibrosis

2021

Background & Aims Progressive fibrosis has been identified as the major predictor of mortality in patients with non-alcoholic fatty liver disease (NAFLD). Several biomarkers are currently being evaluated for their ability to substitute the liver biopsy as the reference standard. Recent clinical studies in NAFLD/NASH patients support the utility of PRO-C3, a marker of type III collagen formation, as a marker for the degree of fibrosis, disease activity, and effect of treatment. Here we establish the healthy reference range, optimal sample handling conditions for both short- and long-term serum storage, and robustness for the PRO-C3 assay. Methods PRO-C3 was measured in 269 healthy volunteers…

NASH-CRN NASH Clinical Research NetworkBiopsyDiseaseAST aspartate aminotransferaseRC799-869Ethnic groupsGastroenterologyNIMBLE Non-Invasive Biomarkers of Metabolic Liver Disease (consortium)FibrosisImmunology and AllergyBody mass indexmedicine.diagnostic_testFatty liverNAS NAFLD Activity ScoreGastroenterologyDiseases of the digestive system. GastroenterologyHospitalsNPV negative predictive valueLiver biopsyBiomarker (medicine)Research Articlemedicine.medical_specialtyNAFLD non-alcoholic fatty liver diseaseADAM A Disintegrin and MetalloproteasesNASH non-alcoholic steatohepatitisReference rangeReference valuesAUROC area under the receiver operating characteristics curveInternal medicineALT alanine aminotransferaseBiopsyInternal MedicinemedicineHumansFIB-4 fibrosis-4Healthy volunteersHepatologyALP alkaline phosphatasebusiness.industryCLSI Clinical and Laboratory Standards InstituteT2DM type 2 diabetes mellitusELF™ test Enhanced Liver Fibrosis testmedicine.diseaseLITMUS Liver Investigation: Testing Marker Utility in Steatohepatitis (consortium)Collagen type IIIFibrosisPPV positive predictive valueReference standardsbusinessBody mass indexBiomarkersNon-alcoholic fatty liver disease
researchProduct