Search results for "Noninvasive ventilation"
showing 10 items of 68 documents
Reducing Rebreathing During Noninvasive Ventilation: Bias Flow or No Bias Flow?
2019
To the Editor : We read with interest the article by Signori et al[1][1] that evaluated CO2 rebreathing during noninvasive ventilation (NIV) via a full face mask connected to a double-limb ventilation circuit with 2 different configurations: (1) a single mask connector directly attached to the Y-
Noninvasive oscillatory ventilation (NHFOV) in infants: Another brick in the wall of paediatric noninvasive ventilation?
2016
EDITORIAL
Material and Technology: Back to the Future for the Choice of Interface for Non-Invasive Ventilation – A Concise Review
2020
Non-invasive ventilation (NIV) has dramatically changed the treatment of both acute and chronic respiratory failure in the last 2 decades. The success of NIV is correlated to the application of the “best ingredients” of a patient’s “tailored recipe,” including the appropriate choice of the selected candidate, the ventilator setting, the interface, the expertise of the team, and the education of the caregiver. The choice of the interface is crucial for the success of NIV. Type (oral, nasal, nasal pillows, oronasal, hybrid mask, helmet), size, design, material and headgears may affect the patient’s comfort with respect to many aspects, such as air leaks, claustrophobia, skin erythema, eye irr…
Bulbar impairment score and survival of stable amyotrophic lateral sclerosis patients after noninvasive ventilation initiation
2018
There is general agreement that noninvasive ventilation (NIV) prolongs survival in amyotrophic lateral sclerosis (ALS) and that the main cause of NIV failure is the severity of bulbar dysfunction. However, there is no evidence that bulbar impairment is a contraindication for NIV. The aim of this study was to determine the effect of bulbar impairment on survival in ALS patients with NIV. ALS patients for whom NIV was indicated were included. Those patients who refused NIV were taken as the control group. 120 patients who underwent NIV and 20 who refused NIV were included. The NIV group presented longer survival (median 18.50 months, 95% CI 12.62–24.38 months) than the no-NIV group (3.00 mont…
Tidal volume and helmet: Is the never ending story coming to an end?
2021
Noninvasive ventilation (NIV) has been increasingly used in acute care setting with various indications, but its use in patients with acute hypoxemic respiratory failure (AHRF) is controversial. In this setting, reliable monitoring of Vt and unintentional leaks is of the utmost importance. The aim of this article is to describe the importance of tidal volume measurement in the context of AHRF treated with NIV.
Use of Helmet CPAP in COVID-19 – A practical review
2021
Helmet CPAP (H-CPAP) has been recommended in many guidelines as a noninvasive respiratory support during COVID-19 pandemic in many countries around the world. It has the least amount of particle dispersion and air contamination among all noninvasive devices and may mitigate the ICU bed shortage during a COVID surge as well as a decreased need for intubation/mechanical ventilation. It can be attached to many oxygen delivery sources. The MaxVenturi setup is preferred as it allows for natural humidification, low noise burden, and easy transition to HFNC during breaks and it is the recommended transport set-up. The patients can safely be proned with the helmet. It can also be used to wean the p…
Comparative bench study evaluation of different infant interfaces for non-invasive ventilation
2018
Abstract Background To compare, in terms of patient-ventilator interaction and performance, a new nasal mask (Respireo, AirLiquide, FR) with the Endotracheal tube (ET) and a commonly used nasal mask (FPM, Fisher and Paykel, NZ) for delivering Pressure Support Ventilation (PSV) in an infant model of Acute Respiratory Failure (ARF). Methods An active test lung (ASL 5000) connected to an infant mannequin through 3 different interfaces (Respireo, ET and FPM), was ventilated with a standard ICU ventilator set in PSV. The test lung was set to simulate a 5.5 kg infant with ARF, breathing at 50 and 60 breaths/min). Non-invasive ventilation (NIV) mode was not used and the leaks were nearly zero. Res…
Noninvasive oscillatory ventilation (NHFOV) in infants: Another brick in the wall of paediatric noninvasive ventilation?
2016
Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study
2015
BACKGROUND: In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. METHODS: A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [T…
Long-term volume-targeted pressure-controlled ventilation: sense or nonsense?
2017
The technology underlying the development of novel ventilatory modes for long-term noninvasive ventilation of patients with chronic hypercapnia is continuously evolving. Volume-targeted pressure-controlled ventilation is a hybrid ventilation mode designed to combine the advantages of conventional ventilation modes, while avoiding their drawbacks. However, manufacturers have created different names and have patented algorithms and set-up variables, which can result in confusion for physicians and respiratory therapists. In addition, clear evidence for the superiority of this novel mode has not yet been established. These factors have most likely hindered more widespread use of this mode in c…