Search results for "Note"

showing 10 items of 10709 documents

Definition of analytical cleaning procedures for archaeological pottery from underwater environments: The case study of samples from Baia (Naples, So…

2021

Abstract This work is focused on a multidisciplinary study of 13 pottery fragments collected in the submerged archaeological site of Baia (Naples, Italy). Founded by the Romans in the 1st century B.C., this archaeological area represents one of the greatest evidences of Roman architecture and it includes ancient ruins whose structures range from maritime villas and imperial buildings. Several diagnostic tests were carried out in order to characterize the archaeological materials, their structure and properties, as well as the alteration and degradation products. Degradation forms in seawater imply not only a variation in the physico-mechanical and chemical properties of the material but als…

Underwater archaeologyMaterials sciencePotteryContext (archaeology)CleaningMultidisciplinary study02 engineering and technology010402 general chemistry01 natural sciencesUltrasoundsSuperficial depositsBiodeterioration Cleaning Pottery Ultrasounds Underwater archaeologylcsh:TA401-492General Materials ScienceArchaeological potteryUnderwaterArchitectureSettore GEO/09 -Georis. Miner.e Appl.Mineral.-Petrogr. per l'Ambi.ed i B.Cult.Mechanical Engineering021001 nanoscience & nanotechnologyArchaeology0104 chemical sciencesBiodeteriorationMechanics of MaterialsUnderwater archaeologylcsh:Materials of engineering and construction. Mechanics of materialsPottery0210 nano-technologyMaterials & Design
researchProduct

Micromechanisms of load transfer in a unidirectional carbon fibre-reinforced epoxy composite due to fibre failures: Part 3. Multiscale reconstruction…

2008

International audience; This third article describes a multiscale process which takes into account the most important microscopic phenomena associated with composite degradation, including fibre fractures and interfacial debonding, overloading of fibres neighbouring a fibre break as well as viscoelastic behaviour of the matrix. The results have been used to accurately predict the macroscopic failure of unidirectional carbon fibre-reinforced epoxy and quantify damage accumulation in pressure vessels made of the same material. The approach described has allowed the acoustic emission activity resulting from fibres breaks to be evaluated and shown how the residual lifetimes of such vessels, whe…

Unidirectional compositeMaterials scienceComposite number[ PHYS.COND.CM-MS ] Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]02 engineering and technologyViscoelasticity0203 mechanical engineeringComposite materialCivil and Structural EngineeringFibre failuresDelaminationPressure vesselsMicromechanicsEpoxy021001 nanoscience & nanotechnologyDurabilityPressure vessel020303 mechanical engineering & transportsAcoustic emissionFailure predictionvisual_artCeramics and Compositesvisual_art.visual_art_medium[PHYS.COND.CM-MS]Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]Multiscale processMicromechanics0210 nano-technology
researchProduct

Modeling of kinetic and static friction between an elastically bent nanowire and a flat surface

2011

Friction forces for a nanowire (NW) elastically bent on flat substrate were investigated both theoretically and experimentally. Models based on elastic beam theory were proposed considering balance of external, frictional, and elastic forces along the NW. The distributed friction force was determined for two cases: (i) the NW was uniformly dragged at its midpoint and bent by kinetic friction forces and (ii) the NW was held in a bent state by static friction forces. The first case considers a uniform distribution of kinetic friction along the NW and enables the measurement of the friction force from the elastically deformed NW profile. The second case exploits the interplay between static fr…

Uniform distribution (continuous)Materials scienceMechanical EngineeringBent molecular geometryNanowireNanotechnologySubstrate (electronics)MechanicsTribologyCondensed Matter PhysicsKinetic energyMomentumMechanics of MaterialsGeneral Materials ScienceWaferJournal of Materials Research
researchProduct

On the study of the vibrational energy levels of Arsine molecule

2008

Abstract We compare two formalisms applied to the vibrational modes of the molecule of AsH 3 of C 3 v molecular symmetry group. Indeed, the close stretching modes of this molecule may be considered as those of a three-dimensional oscillator whereas the bending modes may be considered either as a one-dimensional oscillator of symmetry A 1 and a two-dimensional oscillator of symmetry E or as an approximate three-dimensional oscillator. So, we have applied the U ( p  + 1) formalism to the both stretching and bending modes and introduced coupling terms acting on an appropriate coupled vibrational basis through a local mode formalism. We have then compared the result of our fitting with those ob…

Unitary group approachVibrational energy[ PHYS.QPHY ] Physics [physics]/Quantum Physics [quant-ph]02 engineering and technology01 natural sciencesHot bandchemistry.chemical_compoundArsine[PHYS.QPHY]Physics [physics]/Quantum Physics [quant-ph]Normal mode0103 physical sciencesMolecular symmetryMoleculePhysical and Theoretical Chemistry010306 general physicsSpectroscopyPhysicsVibrational excitationsLocal modeNormal mode021001 nanoscience & nanotechnologyAtomic and Molecular Physics and OpticsVibrationchemistryMolecular vibrationAsH3Atomic physics0210 nano-technology
researchProduct

Evaluation of micro shear bonding strength of two universal dentin bondings to superficial dentin by self etch and etch-and-rinse strategies

2018

Background Universal bondings can be used either with the etch-and-rinse or self-etch technique. Thus, the present study was done to evaluate the micro-shear bonding strength of two types of Universal Bondings to superficial dentin i.e self-etch and etch and rinse. Material and Methods The samples included 70 tooth blocks taken from 35 extracted sound premolar teeth. The superficial dentin was exposed to grinding by 800 grit silicon carbide Disk. The samples were randomly divided into 5 equal groups (14 samples in each group). Scotch bond universal (3M/USA) and All bond universal (BISCO/USA) were applied by self-etch and etch and rinse technique in group 1-4 and Adper Single bond 2 (3M/USA)…

Universal testing machineMaterials scienceBond strengthResearch030206 dentistry02 engineering and technology021001 nanoscience & nanotechnology:CIENCIAS MÉDICAS [UNESCO]CrossheadCommunity and Preventive DentistryShear (sheet metal)03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureStereo microscopeUNESCO::CIENCIAS MÉDICASPremolarmedicineDentinAdhesiveComposite material0210 nano-technologyGeneral Dentistry
researchProduct

Effect of thermocycling and surface treatment on repair bond strength of composite.

2017

BACKGROUND Repair of composite restorations is a conservative method that can increase the longevity and durability of restorations while preserving the tooth structure. Achieving a suitable bond between the old and new composite is difficult. To overcome this problem, some methods have been recommended to increase the repair bond strength of composite.This study aimed to assess the effect of aging by thermocycling (5,000 and 10,000 cycles) and mechanical surface treatments (Er,Cr:YSGG laser and bur) on repair shear bond strength of composite resin. MATERIAL AND METHODS Totally, 120 composite blocks measuring 6x4x4 mm were fabricated of Filtek Z250 composite and were randomly divided into t…

Universal testing machineMaterials scienceBond strengthResearchComposite number030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyDurabilityCrossheadOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineDistilled waterUNESCO::CIENCIAS MÉDICASStereo microscopeAdper single bond 2Composite material0210 nano-technologyGeneral DentistryJournal of clinical and experimental dentistry
researchProduct

Mechanical and dentin bond strength properties of the nanosilver enriched glass ionomer cement

2019

Background The aim of this study was to investigate the mechanical properties and dentin microshear bond strength of a conventional glass ionomer cement (GIC) compared to GIC supplemented with silver nanoparticles (SNPs) at 0.1% and 0.2% (w/w). Material and Methods SNPs were incorporated into a conventional GIC at 0.1% and 0.2% (w/w). The unmodified GIC was used as the control group. Compressive strength, flexural strength, and micro-shear bond strength (µSBS) to dentin were evaluated using a universal testing machine. Surface microhardness was determined using a Vickers microhardness tester. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey’s test. Results GICs co…

Universal testing machineMaterials scienceBond strengthResearchGlass ionomer cement030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyIndentation hardnessSilver nanoparticleOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineCompressive strengthmedicine.anatomical_structureFlexural strengthUNESCO::CIENCIAS MÉDICASDentinmedicineComposite material0210 nano-technologyGeneral Dentistry
researchProduct

Shear bond strength of one-step self-etch adhesives to dentin: Evaluation of NaOCl pretreatment

2018

Background The aim of this study was to evaluate the influence of dentin pretreatment with NaOCl on shear bond strength of four one-step self-etch adhesives with different pH values. Material and methods Bovine permanent incisors were used. Four one-step self-etch adhesives were tested: Adper™ Easy Bond, Futurabond NR, G-aenial Bond, Clearfil S3 Bond. One two-step self-etch adhesive (Clearfil SE Bond) was used as control. Group 1- no pretreatment; group 2- pretratment with 5,25 % NaOCl; group 3- pretreatment with 37 % H3PO4 etching and 5,25 % NaOCl. A hybrid composite resin was inserted into the dentin surface. The specimens were tested in a universal testing machine. The examiners evaluate…

Universal testing machineMaterials scienceBond strengthResearchOne-Step030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyShear bondSelf etch adhesiveOperative Dentistry and EndodonticsClearfil SE Bond03 medical and health sciences0302 clinical medicinemedicine.anatomical_structurestomatognathic systemUNESCO::CIENCIAS MÉDICASDentinmedicineAdhesiveComposite material0210 nano-technologyGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Influence of preheating on mechanical and surface properties of nanofilled resin composites

2019

Background Resin composite preheating is an innovative method that could be clinically beneficial by improving the handling properties, marginal adaptation, and surface properties of uncured nanofilled resin composite materials. There is conflict and unclear information regarding the effect of preheating on the microhardness, fracture toughness and surface roughness of nanofilled resin composites. Thus, it is important to assess whether dental clinicians can adopt preheating procedures without compromising composite mechanical strength. Objective: The purpose of this study was to evaluate the effect of preheating on microhardness, fracture toughness and surface roughness of nanofilled resin…

Universal testing machineMaterials scienceResearchComposite number030206 dentistry02 engineering and technology021001 nanoscience & nanotechnologymedicine.disease_cause:CIENCIAS MÉDICAS [UNESCO]Indentation hardness03 medical and health sciences0302 clinical medicineFracture toughnessIndentationMoldVickers hardness testUNESCO::CIENCIAS MÉDICASBiomaterials and Bioengineering in DentistrySurface roughnessmedicineComposite material0210 nano-technologyGeneral Dentistry
researchProduct

Role of coefficient of thermal expansion on bond strength of ceramic veneered yttrium-stabilized zirconia

2017

Background Incompatible coefficient of thermal expansion (CTE) is supposed to be a reason for chipping of ceramic veneered zirconia. This study evaluates the effect of veneering ceramic at varied CTE on bond strength to zirconia. Material and Methods Zirconia disks (Z, O 10 mm, 1.0 mm thickness) were prepared from Y-TZP (Cercon®) and sintered at 1350°C for 6 hours. All zirconia disks were veneered with ceramics ((O 7.0 mm, 1.5 mm thickness) with varied CTE including VITADur® alpha (VDα), VITAVM®7 (VM7), VITAVM®9 (VM9), Cercon® ceramkiss (CCK), IPSe.max® ceram (IeC), and IPS dSIGN® (IdS) (n=15). The specimens were thermo-cycled (5-55 °C, 500 cycles) prior to determine the shear bond strength…

Universal testing machineProsthetic DentistryMaterials scienceBond strengthWeibull modulusResearchchemistry.chemical_element030206 dentistry02 engineering and technologyYttrium:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyThermal expansionRod03 medical and health sciences0302 clinical medicinechemistryvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumCubic zirconiaCeramicComposite material0210 nano-technologyGeneral Dentistry
researchProduct