Search results for "Nuclear and High Energy Physics"
showing 10 items of 8241 documents
Oxy-nitrides characterization with a new ERD-TOF system
2017
Abstract A new time-of-flight (TOF) camera was installed on Elastic Recoil Detection (ERD) measurement setup on the Tandem Accelerator at Universite de Montreal. The camera consists of two timing detectors, developed and built by the Jyvaskyla group, that use a thin carbon foil and microchannel plates (MCP) to produce the start and stop signals. The position of the first detector is fixed at 18 cm from the target, while the position of the second detector can be varied between 50 and 90 cm from the first detector. This allows to increase time resolution by increasing the distance between the time-of-flight detectors or to increase solid angle by decreasing the distance. Moving the detector …
Highly-resolved radiocarbon measurements on shells from Kalba, UAE, using carbonate handling system and gas ion source with MICADAS
2019
Abstract The Mini Carbon Dating System (MICADAS) represents a flexible AMS system for measuring radiocarbon samples either in the form of graphite or CO2 gas. We used the possibility to attach a carbonate handling system (CHS) to the gas ion source (GIS) to measure smaller amounts of carbonates ( 3) are used to clean the system. We tested the CHS-GIS combination on heated and unheated archaeological shells of Anadara uropigimelana from Kalba, Sharjah Emirate, United Arab Emirates (UAE). Even though the amount of carbon in the samples was small (4–22 µg C) the performance of the CO2 dating system permits the comparison of trends in the 14C data to stable isotope measurements (δ18O and δ13C)…
X-ray response of CdZnTe detectors grown by the vertical Bridgman technique: Energy, temperature and high flux effects
2016
Abstract Nowadays, CdZnTe (CZT) is one of the key materials for the development of room temperature X-ray and gamma ray detectors and great efforts have been made on both the device and the crystal growth technologies. In this work, we present the results of spectroscopic investigations on new boron oxide encapsulated vertical Bridgman (B-VB) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Several detectors, with the same electrode layout (gold electroless contacts) and different thicknesses (1 and 2.5 mm), were realized: the cathode is a planar electrode covering the detector surface (4.1×4.1 mm2), while the anode is a central electrode (2×2 mm2) surrounded by a guard-rin…
Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.
2017
Cadmium-zinc-telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2â...mm-thick CZT pixel detector, with pixel pitches of 500 and 250â...μm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response …
Dual-polarity pulse processing and analysis for charge-loss correction in cadmium–zinc–telluride pixel detectors
2018
Charge losses at the inter-pixel gap are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. In this work, an original technique able to correct charge losses occurring after the application of charge-sharing addition (CSA) is presented. The method, exploiting the strong relation between the energy after CSA and the beam position at the inter-pixel gap, allows the recovery of charge losses and improvements in energy resolution. Sub-millimetre CZT pixel detectors were investigated with both uncollimated radiation sources and collimated synchrotron X-rays, at energies below and above the K-shell absorption energy of the CZT material. The detectors are DC coupled to fast and low…
Femtosecond Structural Dynamics of Proteins
2016
Proteins are the workhorses of living cells, providing essential functions such as structural support, signal transduction, enzymatic catalysis, transport and storage of small ligands. Atomic-resolution structures obtained with conventional X-ray crystallography show proteins essentially as static. In reality, however, proteins move and their motion is crucial for functioning. Although the structure and dynamics of proteins are intimately related, they are not equally well understood. A very large number of protein structures have been determined, but only a few studies have been able to monitor experimentally the dynamics of proteins in real time. In the last two decades, the availability …
Upgrades of the GANDALPH photodetachment detector towards the determination of the electron affinity of astatine
2020
The Gothenburg ANion Detector for Affinity measurements by Laser PHotodetachment (GANDALPH) has recently been built for measurements of electron affinities (EA) of radioisotopes. A first measurement campaign is aimed towards the determination of the EA of astatine, the rarest naturally occurring element on earth. In this work we present several upgrades of GANDALPH which have been implemented in order to facilitate EA measurements of radioisotopes where only low intensity ion beams (< 1pA) can be produced.
Quantification of propagating and standing surface acoustic waves by stroboscopic X-ray photoemission electron microscopy.
2018
The quantification of surface acoustic waves (SAWs) in LiNbO3 piezoelectric crystals by stroboscopic X-ray photoemission electron microscopy (XPEEM), with a temporal smearing below 80 ps and a spatial resolution below 100 nm, is reported. The contrast mechanism is the varying piezoelectric surface potential associated with the SAW phase. Thus, kinetic energy spectra of photoemitted secondary electrons measure directly the SAW electrical amplitude and allow for the quantification of the associated strain. The stroboscopic imaging combined with a deliberate detuning allows resolving and quantifying the respective standing and propagating components of SAWs from a superposition of waves. Furth…
Evidence for the production of three massive vector bosons with the ATLAS detector
2019
A search for the production of three massive vector bosons in proton–proton collisions is performed using data at TeV recorded with the ATLAS detector at the Large Hadron Collider in the years 2015–2017, corresponding to an integrated luminosity of 79.8 fb−1. Events with two same-sign leptons ℓ (electrons or muons) and at least two reconstructed jets are selected to search for . Events with three leptons without any same-flavour opposite-sign lepton pairs are used to search for , while events with three leptons and at least one same-flavour opposite-sign lepton pair and one or more reconstructed jets are used to search for . Finally, events with four leptons are analysed to search for and .…
Measurement of the W boson mass
1996
The W boson mass is measured using proton-proton collision data at root s = 13 TeV corresponding to an integrated luminosity of 1.7fb(-1) recorded during 2016 by the LHCb experiment. With a simultaneous fit of the muon q/p(T) distribution of a sample of W ->mu y decays and the phi* distribution of a sample of Z -> mu mu decays the W boson mass is determined to be