Search results for "Nuclear engineering"

showing 10 items of 533 documents

Equivalent detector models for the simulation of efficiency response of an HPGe detector with PENELOPE code

2019

In this work, some ‘equivalent’ models for the simulation of efficiency response of a High-Purity Germanium (HPGe) detector, installed inside a ‘low background’ bunker in the Engineering Department of the University of Palermo, were developed. The main feature was to attribute the uncertainties of the model to only one of the parameters, the dead layer of the detector, keeping unchanged the other data provided by the manufacturer. With this technique, using the Monte Carlo PENELOPE code in the 2011 version, the efficiency response was evaluated and compared with the previous one performed with MCNP5 code. The validation of equivalent models is performed by comparing the simulation results w…

PhysicsNuclear and High Energy PhysicsRadiationSettore ING-IND/20 - Misure E Strumentazione NucleariNuclear engineeringDetectorCondensed Matter PhysicsSemiconductor detectormodellingefficiencyCode (cryptography)General Materials ScienceHPGe detectorHpge detectorGamma ray spectrometryMonte Carlo
researchProduct

MCNP5 modelling of HPGe detectors for efficiency evaluation in gamma-ray spectrometry

2009

A modelling of HPGe detectors was performed through simulation with the MCNP5 Monte Carlo code. The simulation results concerning the values of the main physical parameters of the detector are in most cases different from those provided by the manufacturer. The use of “single-line” sources allows us to suitably modify the parameter values used in the detector model. For a detector model, the simulation assesses the distribution of photopeak and total efficiency for point sources, whereas for extended sources a control volume approach allows us to determine elementary efficiency behaviours. An integration of elementary efficiencies over the entire sample volume allows us to evaluate global e…

PhysicsNuclear and High Energy PhysicsRadiationgamma-ray spectrometrySettore ING-IND/20 - Misure E Strumentazione NucleariNuclear engineeringMonte Carlo methodDetectorTotal efficiencyAnalytical chemistryCondensed Matter PhysicsControl volumeSample volumeefficiencyGeneral Materials SciencePoint (geometry)HPGe detectorγ ray spectrometryHpge detectorMonte Carlo
researchProduct

Applications of the pulsed gas stripper technique at the GSI UNILAC

2017

Abstract In the frame of an upgrade program for the GSI UNILAC, preparing it for the use as an injector system for FAIR, a pulsed gas stripper cell was developed. It utilizes the required low duty cycle by applying a pulsed gas injection instead of a continuous gas inlet. The resulting lower gas consumption rate enables the use of low-Z gas targets over a wide range of stripper target thicknesses. The setup enables an increased flexibility for the accelerator by allowing the gas stripper to be used in time-sharing beam operation matching the capabilities of the GSI UNILAC like the acceleration of different ion beams in quasi-parallel operation. Measured charge state distributions of 238 U, …

PhysicsNuclear and High Energy PhysicsRange (particle radiation)010308 nuclear & particles physicsNuclear engineeringInjector01 natural scienceslaw.inventionIonAccelerationUpgradelawDuty cycle0103 physical sciences010306 general physicsGas consumptionInstrumentationBeam (structure)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

First feasibility study for EXL prototype detectors at the ESR and detector simulations

2009

This contribution presents some results from the first feasibility measurement performed at GSI using a 350 MeV/nucleon 136 Xe beam and a Hydrogen gas-jet target. In this feasibility study, one element of every possible detection part of the future EXL detection system was investigated. In addition, simulation results for EXL setup will be presented.

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyNuclear engineeringDetectormedicineGeneral Physics and AstronomyMedical physicsBeam (structure)International journal of modern physics e-Nuclear physics
researchProduct

Gyrotron-driven high current ECR ion source for boron-neutron capture therapy neutron generator

2014

Abstract Boron-neutron capture therapy (BNCT) is a perspective treatment method for radiation resistant tumors. Unfortunately its development is strongly held back by a several physical and medical problems. Neutron sources for BNCT currently are limited to nuclear reactors and accelerators. For wide spread of BNCT investigations more compact and cheap neutron source would be much more preferable. In present paper an approach for compact D–D neutron generator creation based on a high current ECR ion source is suggested. Results on dense proton beams production are presented. A possibility of ion beams formation with current density up to 600 mA/cm 2 is demonstrated. Estimations based on obt…

PhysicsNuclear and High Energy Physicsta114Nuclear engineeringPhysics::Medical PhysicsNuclear TheoryRadiationIon sourcelaw.inventionNeutron captureNeutron generatorNeutron fluxlawGyrotronNeutron sourceNeutronNuclear ExperimentInstrumentationta217Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Dangerous effects induced on power MOSFETs by terrestrial neutrons: A theoretical study and an empirical approach based on accelerated experimental a…

2013

This paper investigates the effects that terrestrial neutrons can induce on power MOSFETs when they are biased during their normal working conditions especially in inverters for photovoltaic applications. After a brief review of power MOSFETs failure phenomena caused by neutron irradiation (with emphasis on so called “Single Event Effects” (SEE)), the results of an accelerated test performed with the Am-Be source at the University of Palermo are discussed.

PhysicsNuclear engineeringEmphasis (telecommunications)Photovoltaic systemElectronic engineeringNeutronPower MOSFETNeutron irradiation
researchProduct

Modeling moderated proportional neutron counters using the Geant4 toolkit and the application to detection of fast neutron burst

2014

PhysicsNuclear reactionEnergy absorptionNuclear engineeringMonte Carlo methodNeutronNucleonNeutron temperatureCalculation methodsProceedings of 10th Latin American Symposium on Nuclear Physics and Applications — PoS(X LASNPA)
researchProduct

Low Energy Protons at RADEF - Application to Advanced eSRAMs

2014

A low energy proton facility has been developed at RADEF, Jyvskyl, Finland. The proton energy selection, calibration and dosimetry are described. The first experiment with external users was performed using two memory test vehicles fabricated with 28 nm technology. Examples of single event upset measurements in the test vehicles embedded SRAMs (eSRAMs) as a function of proton energy are provided.

PhysicsProtonta114ta213business.industryNuclear engineeringElectrical engineeringProton energySEE testLow energyLow energy proton facilitySingle event upsetCalibrationDosimetryMemory testbusiness
researchProduct

First online operation of TRIGA-TRAP

2020

Abstract We report on the successful coupling of the Penning-trap mass spectrometry setup TRIGA-TRAP to the research reactor TRIGA Mainz. This offers the possibility to perform direct high-precision mass measurements of short-lived nuclei produced in neutron-induced fission of a 235 U target located near the reactor core. An aerosol-based gas-jet system is used for efficient transport of short-lived neutron-rich nuclei from the target chamber to a surface ion source. In conjunction with new ion optics and extended beam monitoring capabilities, the experimental setup has been fully commissioned. The design of the surface ion source, efficiency studies and first results are presented.

PhysicsSpeichertechnik - Abteilung BlaumNuclear and High Energy PhysicsFission products010308 nuclear & particles physicsFissionNuclear engineeringNuclear TheoryMass spectrometry01 natural sciencesIon sourceTRIGAIonNuclear reactor core0103 physical sciencesResearch reactorNuclear Experiment010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

3-D Shielding Analyses of the Vertical and Mid-Plane Ports in ITER

1996

A three dimensional (3-D) shielding analysis of the International Thermonuclear Experimental Reactor (ITER) has been performed with the aim of calculating the nuclear heating on the magnet system, correlating it to the existing vertical and horizontal ports. When these openings are left unshielded, more than 50 kW are calculated for the upper half of Toroidal Field Coil system and two of the Poloidal Field Coils. A simple plug, with same thickness as of the vacuum vessel can lower the heating to meet the imposed requirements. 5 refs., 6 figs., 4 tabs.

PhysicsThermonuclear fusionNuclear heatingPlane (geometry)020209 energyNuclear engineeringMonte Carlo methodGeneral Engineering02 engineering and technology01 natural sciences010305 fluids & plasmaslaw.inventionNuclear physicsElectromagnetic coillawMagnet0103 physical sciencesElectromagnetic shielding0202 electrical engineering electronic engineering information engineeringSpark plugFusion Technology
researchProduct