Anterior limbic alpha-like activity: a low resolution electromagnetic tomography study with lorazepam challenge
2005
Summary Objective To verify findings of an independently regulated anterior limbic alpha band source. Methods In a randomised cross-over study, the spontaneous EEG was recorded in nine healthy subjects after i.v. lorazepam or placebo. Intracerebral current densities within classical frequency bands were estimated with low resolution electromagnetic tomography [LORETA] and compared between groups with t -statistical parametric mapping [SPM{ t }]. A region-of-interest [ROI] based method was used to compare frontal and occipital alpha band activity changes. Results Irrespective of treatment group, local maxima of alpha band power were localised both in the occipital lobe, Brodman area [BA] 18,…
Accuracy of SWI sequences compared to T2*-weighted gradient echo sequences in the detection of cerebral cavernous malformations in the familial form
2016
Purpose The purpose of this study was to assess the accuracy of susceptibility-weighted imaging (SWI), compared with T2*-weighted gradient echo (GRE) imaging in assessing cerebral cavernous malformations. Materials and methods We retrospectively evaluated 21 patients with a familial form of cavernous malformation. Magnetic resonance (MR) protocol included non-enhanced and contrast-enhanced fast-spin echo (FSE) T1-weighted sequences, FSE T2-weighted sequences, fluid-attenuated inversion-recovery (FLAIR), GRE T2*-weighted and SWI sequences. Images were reviewed in consensus by two expert neuroradiologists to assess the location, number, size and conspicuity of the lesions on T2*-weighted GRE …
Asymmetric metabolic profile in mesial temporal lobes: Localized H-1 MR spectroscopy in healthy right-handed and non-right-handed subjects
1996
International audience; Abstract: PURPOSE: To determine a possible asymmetric metabolic profile in right-handed and non-right-handed healthy subjects by comparing proton spectra from temporal lobes. MATERIALS AND METHODS: Twenty-eight healthy adults (17 right-handers, 11 non-right-handers) underwent magnetic resonance (MR) imaging and single-voxel MR spectroscopy. N-acetylaspartate (NAA), choline (Cho), and creatine (Cr) peak areas were measured. RESULTS: Volume of hippocampal formations was larger on the right in right-handers (right volume: 4.04 cm(3) +/- 0.67 vs left volume: 3.84 cm(3) +/- 0.62; P = .00004) and in non-right-handers (right volume: 4.22 cm(3) +/- 0.78 vs left volume: 4.05 …
Modulation of intracortical inhibition induced by low- and high-frequency repetitive transcranial magnetic stimulation.
2001
We studied the changes of duration of subsequent silent periods (SPs) during repetitive magnetic stimulation (rTMS) trains of ten stimuli delivered at low (1 Hz) and high (7 Hz) frequencies. The effects at different intensities of stimulation (motor threshold, MT, 115% and 130% above the MT) were also evaluated. rTMS was performed in eight healthy subjects with a figure-of-eight coil placed over the hand motor area. The SP was recorded from abductor pollicis brevis (APB) muscle during a voluntary contraction of 30% of maximum effort. rTMS at 1-Hz frequency progressively decreased the duration of SP, whereas an alternating pattern of smaller and larger values was observed during trains at 7-…
Amplitudes of laser evoked potential recorded from primary somatosensory, parasylvian and medial frontal cortex are graded with stimulus intensity
2003
Intensity encoding of painful stimuli in many brain regions has been suggested by imaging studies which cannot measure electrical activity of the brain directly. We have now examined the effect of laser stimulus intensity (three energy levels) on laser evoked potentials (LEPs) recorded directly from the human primary somatosensory (SI), parasylvian, and medial frontal cortical surfaces through subdural electrodes implanted for surgical treatment of medically intractable epilepsy. LEP N2* (early exogenous/stimulus-related potential) and LEP P2** (later endogenous potential) amplitudes were significantly related to the laser energy levels in all regions, although differences between regions w…
Analysis of LDL and HDL size and number by nuclear magnetic resonance in a healthy working population: The LipoLab Study
2020
Background and aim Atherosclerosis is the underlying process in cardiovascular disease (CVD), the first cause of death in developed countries. We aimed to identify people with no known CVD and normal values of LDL-C and HDL-C, but with alterations in the number and size of lipoprotein particles (as measured by nuclear magnetic resonance [NMR]) and to analyse their sociodemographic, clinical and biochemical characteristics. Methods Cross-sectional study in occupational risks prevention centre in Castellon (Spain) in 2017 and 2018, in consecutively recruited adults (18-65 years) with no known CVD. Sociodemographic, clinical and biochemical variables were collected. Lipid profiles were analyse…
1H and 13C HR-MAS spectroscopy of intact biopsy samples ex vivo and in vivo 1H MRS study of human high grade gliomas.
2004
High-resolution magic angle spinning (HR-MAS) one- and two-dimensional 1H and 13C nuclear magnetic resonance (NMR) spectroscopy has been used to study intact glioblastoma (GBM) brain tumour tissue. The results were compared with in vitro chemical extract and in vivo spectra. The resolution of 1H one-dimensional, 1H TOCSY and 13C HSQC HR-MAS spectra is comparable to that obtained on perchloric extracts. 13C HSQC HR-MAS spectra have been particularly useful for the identification of 37 different metabolites in intact biopsy tumours, excluding water and DSS components. To our knowledge, this is the most detailed assignment of biochemical compounds obtained in intact human tissue, in particular…
Nuclear magnetic resonance imaging with hyperpolarised helium-3
1996
Abstract Summary Background Magnetic resonance imaging (MRI) relies on magnetisation of hydrogen nuclei (protons) of water molecules in tissue as source of the signal. This technique has been valuable for studying tissues that contain significant amounts of water, but biological settings with low proton content, notably the lungs, are difficult to image. We report use of spin-polarised helium-3 for lung MRI. Methods A volunteer inhaled hyperpolarised 3 He to fill the lungs, which were imaged with a conventional MRI detector assembly. The nuclear spin polarisation of helium, and other noble gases, can be greatly enhanced by laser optical pumping and is about 10 5 times larger than the polari…
Analyzing gastrocnemius EMG-activity and sway data from quiet and perturbed standing.
2007
In an experiment, we combined force plate measurements and surface EMG in studying quiet and perturbed standing, involving MS (Multiple sclerosis) and controls. The aim of this paper is to report the results thus obtained on the relation between filtered gastrocnemius (GA) EMG and the anterior-posterior center-of-pressure (A/P COP) coordinate. The main finding is the good correspondence between A/P COP and the filtered GA EMG in the low frequency range. The EMG envelope was calculated using a zero-lag filter. Combining this with time shifts around 250-350 ms produced a high correlation (85.5+/-8.4%) between the GA-EMG envelope and the A/P COP. This EMG-COP relation was closest when using a …
Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI
1999
We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional …