Search results for "Numerical aperture"
showing 10 items of 20 documents
Resolution enhancement in quantitative phase microscopy
2019
Quantitative phase microscopy (QPM), a technique combining phase imaging and microscopy, enables visualization of the 3D topography in reflective samples, as well as the inner structure or refractive index distribution of transparent and translucent samples. Similar to other imaging modalities, QPM is constrained by the conflict between numerical aperture (NA) and field of view (FOV): an imaging system with a low NA has to be employed to maintain a large FOV. This fact severely limits the resolution in QPM up to 0.82λ/NA, λ being the illumination wavelength. Consequently, finer structures of samples cannot be resolved by using modest NA objectives in QPM. Aimed to that, many approaches, suc…
Common-path phase-shifting digital holographic microscopy: A way to quantitative phase imaging and superresolution
2008
We present an experimental setup useful for complex amplitude evaluation and phase image quantification of three-dimensional (3-D) samples in digital holographic microscopy (DHM). It is based on a common-path interferometric configuration performed by dividing the input plane in two contiguous regions and by placing a translation grating near to the Fourier plane. Then, complex amplitude distribution of the sample under test is recovered with phase-shifting standard method obtained by moving the grating using a linear motion stage. Some experimental results of an USAF resolution test are presented for different numerical aperture (NA) microscope lenses. In a second part, the proposed setup …
Random angular coding for superresolved imaging.
2010
In this paper, we present a new approach capable of working under coherent and incoherent illumination for achieving superresolution by random coding of the object's angular information. By placing two static random masks in optically conjugate planes inside an aperture-limited imaging setup, one may obtain a transmitted image containing spatial resolution higher than the one obtained without the masks. As the most noticeable fact, the superresolution effect is obtained without imposing any restrictions either in the time domain or in the field-of-view domain but rather only in the dynamic range of the camera device. Experimental verifications for the proposed technique with incoherent illu…
In-situ diagnostic of ultrashort probes based on Kerr-index transient Bragg grating
2019
Pump-probe experiments are essential tools to investigate ultrafast dynamics of laser-matter interaction. We are particularly interested in the dynamics of transparent dielectrics under high numerical aperture focusing. Two main challenges arise for the weak probe pulse. First, we need a precise knowledge of the probe delay with respect to the pump pulse. Second, dispersion compensation of the ultrashort probe pulse generally requires a prism compressor, which can generate angular dispersion, and therefore incorrect interpretation of the pumpprobe measurements.
Inverse photonic-crystal-fiber design through geometrical and material scalings
2020
Geometrical and material - i.e., external and internal - scaling symmetries are exploited to obtain approximated analytical expressions for the mode effective index, group index, and chromatic dispersion of a scaled fiber. Our results include material refractive index scaling that changes the numerical aperture. First, the analytical expressions are successfully tested with a conventional step index fiber in a broadband range of wavelengths, from 1 to 2 mu m. Then, we establish a procedure to adapt the analytical expressions to photonic crystal fibers (PCFs) and illustrate its application in a triangular PCF with circular holes. These adapted analytical expressions show good agreement with …
Long working range light field microscope with fast scanning multifocal liquid crystal microlens array
2018
The light field microscope has the potential of recording the 3D information of biological specimens in real time with a conventional light source. To further extend the depth of field to broaden its applications, in this paper, we proposed a multifocal high-resistance liquid crystal microlens array instead of the fixed microlens array. The developed multifocal liquid crystal microlens array can provide high quality point spread function in multiple focal lengths. By adjusting the focal length of the liquid crystal microlens array sequentially, the total working range of the light field microscope can be much extended. Furthermore, in our proposed system, the intermediate image was placed i…
Depth-of-Field Enhancement in Integral Imaging by Selective Depth-Deconvolution
2014
One of the major drawbacks of the integral imaging technique is its limited depth of field. Such limitation is imposed by the numerical aperture of the microlenses. In this paper, we propose a method to extend the depth of field of integral imaging systems in the reconstruction stage. The method is based on the combination of deconvolution tools and depth filtering of each elemental image using disparity map information. We demonstrate our proposal presenting digital reconstructions of a 3-D scene focused at different depths with extended depth of field.
Superresolved digital in-line holographic microscopy for high-resolution lensless biological imaging.
2010
Digital in-line holographic microscopy (DIHM) is a modern approach capable of achieving micron-range lateral and depth resolutions in three-dimensional imaging. DIHM in combination with numerical imaging reconstruction uses an extremely simplified setup while retaining the advantages provided by holography with enhanced capabilities derived from algorithmic digital processing. We introduce superresolved DIHM incoming from time and angular multiplexing of the sample spatial frequency information and yielding in the generation of a synthetic aperture (SA). The SA expands the cutoff frequency of the imaging system, allowing submicron resolutions in both transversal and axial directions. The pr…
Axial superresolution by synthetic aperture generation
2008
The use of tilted illumination onto the input object in combination with time multiplexing is a useful technique to overcome the Abbe diffraction limit in imaging systems. It is based on the generation of an expanded synthetic aperture that improves the cutoff frequency (and thus the resolution limit) of the imaging system. In this paper we present an experimental validation of the fact that the generation of a synthetic aperture improves not only the lateral resolution but also the axial one. Thus, it is possible to achieve higher optical sectioning of three-dimensional (3D) objects than that defined by the theoretical resolution limit imposed by diffraction. Experimental results are provi…
Ultrathin high-index metasurfaces for shaping focused beams
2015
The volume size of a converging wave, which plays a relevant role in image resolution, is governed by the wavelength of the radiation and the numerical aperture (NA) of the wavefront. We designed an ultrathin (λ/8 width) curved metasurface that is able to transform a focused field into a high-NA optical architecture, thus boosting the transverse and (mainly) on-axis resolution. The elements of the metasurface are metal-insulator subwavelength gratings exhibiting extreme anisotropy with ultrahigh index of refraction for TM polarization. Our results can be applied to nanolithography and optical microscopy. Spanish Ministry of Economy and Competitiveness (MEC) (TEC2013-50416-EXP).