Search results for "OPTICS"
showing 10 items of 10033 documents
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients
2011
PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…
Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.
2013
PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …
Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.
2006
ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…
Refractive lens exchange with an array multifocal intraocular lens.
2002
ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…
A 12-month Prospective Study of Tear Osmolarity in Contact Lens Wearers Refitted with Daily Disposable Soft Contact Lenses
2020
SIGNIFICANCE Tear osmolarity has been reported as one of the best diagnostic tests for dry eye disease and its management. Contact lens wear is thought to influence tear homeostasis. Understanding how regular wear of contact lenses and their type affect tear osmolarity is important. PURPOSE The purpose of this study was to assess changes in tear osmolarity and ocular symptoms over a period of 12 months following refitting contact lens wearers with daily disposable contact lenses. METHODS Fifty subjects aged (mean ± SD) 26 ± 4 years were refitted with either silicone-hydrogel (delefilcon A, SiHy, n = 34) or hydrogel (omafilcon A, Hy, n = 16) daily disposable soft contact lenses. Study includ…
Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness
2013
Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…
Meibomian glands structure in daily disposable soft contact lens wearers: a one‐year follow‐up study
2020
Purpose To assess the impact of daily disposable soft contact lenses on meibomian gland morphology over a period of 12 months. Methods Forty-one subjects (33 experienced and 8 neophytes) were fitted with either silicone-hydrogel or hydrogel daily contact lenses. The study protocol included four visits: baseline, day-2 for contact lens fit and follow-up measurements, as well as after 6 and 12 months of lens wear. Non-contact infrared meibography images were acquired with Keratograph 5M topographer (www.oculus.de) and analysed with an automated method, which objectively estimates the area of gland atrophy, gland length and width, number of glands and gland irregularity. Protocol at follow-up …
Effect of 3rd-order aberrations on human vision
2007
To investigate the effect of 3rd-order aberrations on human vision.Grupo de Ciencias de la Visión, University of Murcia, Murcia, Spain.The 3rd-order aberrations coma and trefoil were induced with purpose-designed soft contact lenses, 3 inducing coma (low [0.05 microm], medium [0.13 microm], high [1.03 microm]) and 3 inducing trefoil (low [0.07 microm], medium [0.17 microm], high [0.96 microm]). Monocular high-contrast (HCVA) and low-contrast (LCVA) visual acuities and contrast sensitivity were measured in 11 subjects wearing contact lenses with a 5.0 mm artificial pupil.The reduction in HCVA and LCVA was statistically significant only for the highest coma and trefoil values (P.0001). For co…
Evaluating tear clearance rate with optical coherence tomography
2017
Purpose: To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. Methods: TCR was classified as the percentage decrease of the inferior tear meniscus height 30s after instillation of 5uL 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean +/- standard deviation) 25.5 +/- 4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR …