Search results for "OPTICS"
showing 10 items of 10033 documents
Laser illumination designs for snapshot multi-spectral-line imaging
2019
For multi-spectral imaging, both acquisition time of the spectral image set and the spectral bandwidth of each image have to be minimized. Ultimate performance can be achieved if the set of monochromatic (single-wavelength) spectral images is obtained with a single snapshot — a technique provisionally called "snapshot multi-spectral-line imaging" or SMSLI. Using contemporary RGB colour cameras, up to three spectral line images can be extracted from a snapshot image data cube at specific illumination that comprises only three spectral lines, each of them positioned within one of the detection bands (R, G or B) [1]. Techniques able to provide more spectral line images are under development, a…
Single snapshot RGB multispectral imaging at fixed wavelengths: proof of concept
2014
A concept of single snapshot multispectral imaging by standard RGB image sensors under spectrally-specific illumination comprising a fixed number of narrow spectral lines is discussed and experimentally validated. The limiting conditions, RGB band spectral crosstalk corrections and potential applications for parametric mapping of skin are regarded, along with the preliminary results of the proof-of-concept measurements.
Microvascular blood flow changes of the abductor pollicis brevis muscle during sustained static exercise
2021
A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant cha…
Validity and Reliability of an Instrumented Treadmill with an Accelerometry System for Assessment of Spatio-Temporal Parameters and Impact Transmissi…
2021
Running retraining programs focused on concurrent feedback of acceleration impacts have been demonstrated to be a good strategy to reduce running-related injuries (RRI), as well as to improve running economy and reduce acceleration impacts and injury running incidence. Traditionally, impacts have been registered by mean of accelerometers attached directly to the athletes, which is inaccessible to the entire population, because it requires laboratory conditions. This study investigated the validity and reliability of a new device integrated directly into the treadmill, compared to a traditional acceleration impact system. Thirty healthy athletes with no history of RRI were tested on two sepa…
Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility
2017
Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…
Diffuse reflectance and fluorescence multispectral imaging system for assessment of skin
2014
The diffuse reflectance multispectral imaging technique has been used for distant mapping of in vivo skin chromophores (hemoglobin and melanin). The fluorescence multispectral imaging is not so common for skin applications due to complicity of data acquisition and processing, but could provide additional information about skin fluorophores. Both techniques are compatible, and could be combined into a multimodal solution. The multispectral imaging system Nuance based on liquid crystal tunable filters was adapted for diffuse reflectance and fluorescence spectral imaging of in vivo skin. Uniform illumination was achieved by LED ring light. Combination of four LEDs (warm white, 770 nm, 830 nm a…
Water detection in skin by dual-band photodiodes
2013
Purpose of this study was to develop a simple model for possibilities to detect water in skin by diffuse reflectance spectra. The model is based on comparison of diffuse reflectance spectra when illuminating water sample with LEDs of different wavelengths (1200 nm, and 1450 nm). The illumination LEDs were chosen due to water absorption differences in near-infrared spectral range. For detection, dual-band photodiode DSD2 by Thorlabs was used. Due to differences of water absorption at different wavelengths in the near-infrared spectral region, this correlation could be used for mapping of water content in skin or, in other words, determine relative moisture level in skin. Simple experimental …
Skin haemoglobin mapping: comparison of multi-spectral imaging and selective R-G-B analysis
2010
The multi-spectral imaging technique has been used for distant mapping of in-vivo skin haemoglobin. Besides, potential of selective R-G-B analysis of skin images has been studied under bi-chromatic (532 nm and 635 nm) laser illumination.
Quantitative myocardial perfusion magnetic resonance imaging: the impact of pulsatile flow on contrast agent bolus dispersion.
2011
Myocardial blood flow (MBF) can be quantified using T1-weighted first-pass magnetic resonance imaging (MRI) in combination with a tracer-kinetic model, like MMID4. This procedure requires the knowledge of an arterial input function which is usually estimated from the left ventricle (LV). Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest. The aim of this study was to investigate the dispersion under conditions of physiological pulsatile blood flow, and to simulate its effect on MBF quantification. The dispersion was simulated in coronary arteries using a computational fluid dynamics (CFD) approach. Simulations were accomplished on straight vessels wit…
Determination of chromophore distribution in skin by spectral imaging
2012
Possibilities to determine chromophore distribution in skin by spectral imaging were explored. Simple RGB sensor devices were used for image acquisition. Totally 200 images of 40 different bruises of 20 people were obtained in order to map chromophores bilirubin and haemoglobin. Possibilities to detect water in vitro and in vivo were estimated by using silicon photodetectors and narrow band LEDs. The results show that it is possible to obtain bilirubin and haemoglobin distribution maps and observe changes of chromophore parameter values over time by using a simple RGB imaging device. Water in vitro was detected by using differences in absorption at 450 nm and 950 nm, and 650 nm and 950 nm.