Search results for "ORTHOSES"

showing 10 items of 12 documents

Effect of prefabricated thermoformable foot orthoses on plantar surface temperature after running: A gender comparison.

2020

Abstract There is a lack of evidence about the effect of different type of foot orthoses on plantar surface temperature. Moreover, that effect could be different depending on gender due to anatomical and physiological differences between men and women. The aim of the study was to analyze the effect of a prefabricated thermoformable foot orthosis on plantar surface temperature after running and taking gender differences into account. Thirty recreational runners (15 males, mean (standard deviation): 28 (7) years, 69.7 (6.5) kg, 1.74 (0.05) cm and 22.9 (1.7) kg/m2; and 15 females: 35 (7) years, 55.2 (6.9) kg, 1.63 (0.06) cm and 20.6 (1.9) kg/m2) carried out a maximum incremental test as pre-te…

0106 biological sciencesAdultMalebusiness.product_categoryHeelPhysiology030310 physiologyPlantar surfaceFoot Orthoses010603 evolutionary biology01 natural sciencesBiochemistryRunning03 medical and health sciencesRandom AllocationSex FactorsmedicineHumansTreadmillFoot OrthosesGender comparisonFoot orthosisOrthodontics0303 health sciencesbusiness.industryFootIncremental testShoesmedicine.anatomical_structureFemaleGeneral Agricultural and Biological SciencesbusinessSkin TemperatureFoot (unit)Developmental BiologyJournal of thermal biology
researchProduct

Effects of prefabricated and custom-made foot orthoses on skin temperature of the foot soles after running

2019

OBJECTIVE Foot orthoses are increasingly used by runners despite the controversy about whether their use can reduce the risk of overuse injuries. Some authors have found modifications in plantar pressures with the use of foot orthoses, which could produce changes in the surface skin temperature of the foot soles. The aim of this study was to analyse the effects of custom-made and prefabricated foot orthoses on the skin temperature of different regions of both foot soles after running. APPROACH Twenty-four participants carried out a maximal aerobic speed test as a pre-test, and three running tests at the laboratory wearing different foot orthoses conditions (control, prefabricated and custom…

AdultMalePhysiology0206 medical engineeringBiomedical EngineeringBiophysicsFoot Orthoses02 engineering and technologyRunning03 medical and health sciences0302 clinical medicineFoot solesPhysiology (medical)HumansMedicineFoot OrthosesOrthodonticsFootbusiness.industrySpeed testForefootSkin temperature020601 biomedical engineeringFemaleSkin Temperaturebusiness030217 neurology & neurosurgeryPhysiological Measurement
researchProduct

Effect of custom-made and prefabricated insoles on plantar loading parameters during running with and without fatigue.

2014

Controversy exists whether custom-made insoles are more effective in reducing plantar loading compared to prefabricated insoles. Forty recreational athletes ran using custom-made, prefabricated, and the original insoles of their running shoes, at rest and after a fatigue run. Contact time, stride rate, and plantar loading parameters were measured. Neither the insole conditions nor the fatigue state modified contact time and stride rate. Addressing prevention of running injuries, post-fatigue loading values are of great interest. Custom-made insoles reduced the post-fatigue loading under the hallux (92 vs. 130 kPa, P0.05), medial midfoot (70 vs. 105 kPa, P0.01), and lateral midfoot (62 vs 96…

AdultMalemedicine.medical_specialtyContact timeRestSTRIDEPhysical Therapy Sports Therapy and RehabilitationRunningSports EquipmentPhysical medicine and rehabilitationPressureMedicineHumansOrthopedics and Sports MedicineFoot OrthosesFatiguebusiness.industryRunning injuriesFootEquipment DesignShoesGait analysisAthletic InjuriesFemaleStress MechanicalbusinessJournal of sports sciences
researchProduct

Influence of foot orthosis customisation on perceived comfort during running

2014

Although running is associated with many health benefits, it also exposes the body to greater risk of injury. Foot orthoses are an effective strategy to prevent such injuries. Comfort is an essential element in orthosis design since any discomfort alters the runner's biomechanics, compromising performance and increasing the risk of injury. The present study analyses the perceived comfort of three types of orthoses: custom-made, prefabricated and original running shoe insoles. Nine comfort variables for each insole were assessed in a sample of 40 runners. Custom-made and prefabricated insoles were both perceived as significantly more comfortable than the original insoles. The differences wer…

AdultMalemedicine.medical_specialtybusiness.product_categorybusiness.industryBiomechanicsFoot OrthosesPhysical Therapy Sports Therapy and RehabilitationHuman Factors and ErgonomicsHealth benefitsRunningRunning gaitPhysical medicine and rehabilitationmedicinePhysical therapyHumansFemalebusinessFoot OrthosesGaitFoot (unit)Foot orthosisErgonomics
researchProduct

Force in the Achilles Tendon During Walking With Ankle Foot Orthosis

2009

Background Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. Hypothesis Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. Study Design Controlled laboratory study. Methods In 8 subjects, the maximum force and rate of force development in the Achilles tendon were measured with an optic fiber technique, and the activity of the gastrocnemius, soleus, and tibialis anterior muscles was recorded using electromyography. Trial conditions were walking barefoot and wearing an ankle-foot orthoses set in 3 different positi…

AdultMalemusculoskeletal diseasesOrthotic Devicesmedicine.medical_specialtyHeelPhysical Therapy Sports Therapy and RehabilitationWalkingElectromyographyAchilles TendonBarefootWeight-BearingYoung AdultPhysical medicine and rehabilitationAnkle/foot orthosismedicineHumansOrthopedics and Sports MedicinePostoperative PeriodFoot OrthosesRuptureAchilles tendonmedicine.diagnostic_testElectromyographyFootbusiness.industryEquipment Designmusculoskeletal systemOrthotic deviceBiomechanical Phenomenabody regionsmedicine.anatomical_structureFemaleAnkleAnklebusinesshuman activitiesThe American Journal of Sports Medicine
researchProduct

Effect of Foot Orthoses and Shoes in Parkinson's Disease Patients : A PRISMA Systematic Review

2021

[Abstract] Reduced plantar foot sensation, postural instability, and gait difficulties are characteristic of Parkinson´s disease patients. A systematic review was carried out to determine the effect of the different types of insoles and shoes in these patients. Several databases were used to search for relevant articles reporting Parkinson´s disease patients undergoing treatment with any type of insole and footwear. All titles and abstracts were reviewed independently by two reviewers and the available data were extracted. The study eligibility criteria were any type of experimental study that included Parkinson’s disease patients treated with any type of insole or footwear. Eight studies w…

Balancemedicine.medical_specialtyPasoParkinson's diseasePostural instabilityMedicine (miscellaneous)EquilibrioReviewControlled studiesinsolegaitFootwearInsolePhysical medicine and rehabilitationSensationmedicineFoot OrthosesGaitBalance (ability)PlantillaImportant conclusionbusiness.industryRbalancemedicine.diseaseGaitParkinson diseaseExtremitatsPodologíaCalzadoEnfermedad de ParkinsonfootwearParkinson’s diseaseMedicineSistema nerviós Malaltiesbusiness
researchProduct

Effect of custom-made and prefabricated foot orthoses on kinematic parameters during an intense prolonged run

2020

Foot orthoses are one of the most used strategies by healthy runners in injury prevention and performance improvement. However, their effect on running kinematics throughout an intense prolonged run in this population is unknown. Moreover, there is some controversy regarding the use of custom-made versus prefabricated foot orthoses. This study analysed the effect of different foot orthoses (custom-made, prefabricated and a control condition) on spatio-temporal and angular (knee flexion and foot eversion) kinematic parameters and their behaviour during an intense prolonged run. Twenty-four recreational runners performed three similar tests that consisted of running 20 min on a treadmill at 8…

MaleKinematicsTime Factorsbusiness.product_categoryPhysiologyKneesKinematicsOrthoticsRunning0302 clinical medicineHeart RateMedicine and Health SciencesMedicinePublic and Occupational HealthTreadmillFoot OrthosesMusculoskeletal SystemOrthoticseducation.field_of_studyMultidisciplinaryFeetPhysicsQRBiomechanicsClassical MechanicsEquipment DesignSports ScienceBiomechanical PhenomenaPhysical SciencesEngineering and TechnologyLegsMedicineFemaleAnatomyResearch ArticleBiotechnologyAdultmedicine.medical_specialtySciencePopulationCardiologyFoot OrthosesSTRIDEBioengineering03 medical and health sciencesPhysical medicine and rehabilitationHumansSports and Exercise MedicineeducationExerciseFoot orthosisMechanical PhenomenaBiological Locomotionbusiness.industryBiology and Life SciencesPhysical Activity030229 sport sciencesPhysical FitnessBody LimbsMedical Devices and Equipmentbusinesshuman activities030217 neurology & neurosurgeryPLOS ONE
researchProduct

Effects of medially posted insoles on foot and lower limb mechanics across walking and running in overpronating men.

2017

Anti-pronation orthoses, like medially posted insoles (MPI), have traditionally been used to treat various of lower limb problems. Yet, we know surprisingly little about their effects on overall foot motion and lower limb mechanics across walking and running, which represent highly different loading conditions. To address this issue, multi-segment foot and lower limb mechanics was examined among 11 over-pronating men with normal (NORM) and MPI insoles during walking (self-selected speed 1.70 +/- 0.19 m/s vs 1.72 +/- 0.20 m/s, respectively) and running (4.04 +/- 0.17 m/s vs 4.10 +/- 0.13 m/s, respectively). The kinematic results showed that MPI reduced the peak forefoot eversion movement in …

MaleMOTIONKnee JointOrthoticsKinematicsWalkingORTHOTICSRunning0302 clinical medicineMOMENTSOrthopedics and Sports Medicineta315Rehabilitationmulti-segment foot kinematicsBiomechanicsta3141MechanicsBiomechanical Phenomenamedicine.anatomical_structureKNEEmedicine.medical_specialtyOrthotic DevicesMovementBiomedical EngineeringBiophysicspronationmedially posted insolesjuoksuwalking03 medical and health sciencesmedicinePressureHumansPronationTibiaKINEMATICSTibiabusiness.industryFootForefootANKLE030229 sport sciences217 Medical engineeringORTHOSESBIOMECHANICSbody regionsKineticskineticsREARFOOTCoronal planeAnklebusinesshuman activities030217 neurology & neurosurgeryAnkle JointCenter of pressure (fluid mechanics)Journal of biomechanics
researchProduct

Ankle Foot Orthoses with Wire Insertion

2013

The objective of the work is to present some researches regarding the virtual modelling of external medical devices with wire insertion. Ankle foot orthoses are used to correct and prevent different disfunctions of the human body and also in athlets recovery. The research is motivate by the problems appeared using this medical devices: durability issues, patient confort, manufacturing costs, lightweight, flexible access to shoes, inexpensive, readily available. These issues depends of the wey design, manufacturing technology, materials used, patient behavior, skills manufacturer. Wire insertion in polypropylene is a new approach of orthoses materials.

Manufacturing technologyEngineering drawingEngineeringbusiness.industryAnkle foot orthosesWork (physics)Mechanical engineeringGeneral MedicinePatient behaviorbusinessApplied Mechanics and Materials
researchProduct

Effectiveness and Duration of Plantar Pressure Off-loading by Two Designs of Felt Padding: A Preliminary Study.

2019

Background: The aim of this study was to observe the pressure changes in the felt padding used to off-load pressure from the first metatarsal head, the effects obtained by different designs, and the loss of effectiveness over time. Method: With a study population of 17 persons, two types of 5-mm semicompressed felt padding were tested: one was C-shaped, with an aperture cutout at the first metatarsophalangeal joint, and the other was U-shaped. Pressures on the sole of the foot were evaluated with a platform pressure measurement system at three time points: before fitting the felt padding, immediately afterward, and 3 days later. Results: In terms of decreased mean pressure on the first met…

OrthodonticsMaleMetatarsophalangeal JointAdolescentbusiness.industryFootPlantar pressureFirst metatarsalFoot OrthosesGeneral MedicineEquipment DesignWalkingMiddle AgedPaddingYoung AdultDuration (music)PressureMedicineHead (vessel)HumansFemalebusinessFoot OrthosesMetatarsal BonesJournal of the American Podiatric Medical Association
researchProduct