Search results for "Observer Variation"

showing 10 items of 156 documents

Echocardiographic reference ranges for normal left atrial function parameters results from the EACVI NORRE study

2018

International audience; Aims - To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function we…

Maledeformation imagingPump functionEchocardiography Three-DimensionalSex Factor030204 cardiovascular system & hematologyCohort Studies0302 clinical medicineLeft atrialReference ValuesHealthy volunteersImage Processing Computer-AssistedAge Factoradult echocardiography; deformation imaging; left atrial function; reference values030212 general & internal medicineMultivariate AnalysiObserver VariationHealthy subjectsAge FactorsGeneral MedicineMiddle AgedReference StandardsHealthy VolunteerHealthy VolunteersHomogeneousRadiology Nuclear Medicine and imagingEchocardiographyCardiologyLinear ModelAtrial Function LeftFemale[SDV.IB]Life Sciences [q-bio]/BioengineeringCardiology and Cardiovascular MedicineHumanAdultmedicine.medical_specialtyadult echocardiographyStatistics Nonparametric03 medical and health sciencesSex FactorsInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingHeart AtriaLeft atrial functionbusiness.industryreference valueMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREReference valuesMultivariate AnalysisLinear ModelsReference StandardParameterCohort StudieLarge groupbusiness
researchProduct

CT angiography versus intraarterial digital subtraction angiography for assessment of aortoiliac occlusive disease.

1997

The purpose of this study was to evaluate the accuracy of CT angiography (CTA) with a single helical acquisition for assessment of stenoses and occlusions of the iliac arteries.In our prospective study, intraarterial digital subtraction angiography and IV CTA were performed from the suprarenal aorta to below the femoral bifurcation in 30 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were also obtained. The accuracy of CTA with and without analysis of axial images was determined.Sensitivity and specificity of CTA were 100% for iliac artery occlusions with a confidence interval 85-100% and 97-100%, respectively. When axial scans were interpret…

Malemedicine.medical_specialtyAortic DiseasesAortoiliac occlusive diseaseArterial Occlusive DiseasesIliac ArterySensitivity and SpecificitySuprarenal Aortamedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAorta AbdominalProspective StudiesObserver VariationAortamedicine.diagnostic_testbusiness.industryVascular diseasemusculoskeletal neural and ocular physiologyAngiographyAngiography Digital SubtractionGeneral MedicineDigital subtraction angiographyMiddle Agedmedicine.diseaseStenosisAngiographyArterial Occlusive DiseasesRadiologybusinessTomography X-Ray Computedpsychological phenomena and processesAJR. American journal of roentgenology
researchProduct

Endoscopic assessment and grading of Barrett's esophagus using magnification endoscopy and narrow-band imaging: accuracy and interobserver agreement …

2010

Background: Three different classification systems for the evaluation of Barrett's esophagus (BE) using magnification endoscopy (ME) and narrow-band imaging (NBI) have been proposed. Until now, no comparative and external evaluation of these systems in a clinical-like situation has been performed. Objective: To compare and validate these 3 classification systems. Design: Prospective validation study. Setting: Tertiary-care referral center. Nine endoscopists with different levels of expertise from Europe and Japan participated as assessors. Patients: Thirty-two patients with long-segment BE. Interventions: From a group of 209 standardized prospective recordings collected on BE by using …

Malemedicine.medical_specialtyBarrett EsophagusSDG 3 - Good Health and Well-beingPredictive Value of TestsmedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesEsophagusGrading (tumors)AgedObserver VariationNarrow-band imagingMucous Membranebusiness.industryGastroenterologyIntestinal metaplasiaMiddle Agedmedicine.diseaseGastric typeImage EnhancementMagnification endoscopySurgerymedicine.anatomical_structureDysplasiaBarrett's esophagusFemaleRadiologyEsophagoscopybusinessPrecancerous ConditionsGastrointestinal Endoscopy
researchProduct

Interobserver variation in assessment of gastric premalignant lesions: higher agreement for intestinal metaplasia than for atrophy.

2013

Background Either atrophy or intestinal metaplasia of the gastric mucosa are considered premalignant lesions. The new operative link for gastritis assessment staging system is based on the detection of atrophy, and the operative link for assessment of intestinal metaplasia staging system is based on the detection of intestinal metaplasia. Good interobserver agreement is necessary for identification of any premalignant condition. Aims The aim of this study was to compare the agreement between findings of gastric atrophy and intestinal metaplasia by expert and general pathologists and to analyze the possible reasons behind any possible disagreement. Methods Patients with dyspeptic symptoms, a…

Malemedicine.medical_specialtyBiopsyGastroenterologySeverity of Illness IndexAtrophyStomach NeoplasmsInternal medicineMetaplasiaBiopsymedicineGastric mucosaHumansAntrumAgedObserver VariationMetaplasiaHepatologybiologymedicine.diagnostic_testbusiness.industryGastroenterologyIntestinal metaplasiaHelicobacter pyloriMiddle Agedmedicine.diseasebiology.organism_classificationdigestive system diseasesmedicine.anatomical_structureGastric MucosaFemaleClinical Competencemedicine.symptomGastritisAtrophybusinessPrecancerous ConditionsEuropean journal of gastroenterologyhepatology
researchProduct

Dobutamine stress Doppler echocardiography: reproducibility and physiologic left ventricular filling patterns

1997

Qualitatively, dobutamine stress echocardiography has become an established procedure. Quantitative results are in great demand but this is still difficult due to limited endo- and epicardial border definition. Transmitral Doppler variables are strictly quantitative and less subjective. Furthermore, ischemic alterations precede systolic ones (ischemic cascade). There are preliminary reports of the utility of dobutamine stress Doppler echocardiography, but proof of reproducibility and left ventricular filling patterns are still lacking. Fourteen healthy volunteers (10 men, 4 women, median age 25.9 years, range 21-32 years) were investigated according to the usual dobutamine stress echocardio…

Malemedicine.medical_specialtyCardiotonic AgentsMyocardial IschemiaIschemiaHemodynamicsCoronary DiseaseDoppler echocardiographySensitivity and SpecificityVentricular Function Leftsymbols.namesakeReference ValuesDobutamineInternal medicinemedicineHumansObserver VariationReproducibilitymedicine.diagnostic_testVascular diseasebusiness.industryHemodynamicsReproducibility of ResultsIschemic cascademedicine.diseaseEchocardiography DopplerExercise TestsymbolsCardiologyFemaleDobutamineCardiology and Cardiovascular MedicinebusinessDoppler effectmedicine.drugInternational Journal of Cardiology
researchProduct

Analysis of myocardial perfusion or myocardial function for detection of regional myocardial abnormalities. An echocardiographic multicenter comparis…

2007

Background: Echocardiography based myocardial perfusion imaging and regional wall motion analysis are used for evaluation of coronary artery disease and regional myocardial abnormalities. Aim: This study sought to compare myocardial contrast echocardiography (MCE) and 2D echocardiography with regard to interobserver variability and detection of regional myocardial abnormalities. Methods: In 70 patients evenly distributed between three ejection fraction groups based on biplane cineventriculography (>55%, 35-55%, <35%), unenhanced and contrast enhanced 2D echocardiography and myocardial contrast echocardiography (MCE; SonoVue (R); Bracco) were performed. Regional watt motion and myocardial pe…

Malemedicine.medical_specialtyContrast MediaCoronary DiseaseRisk AssessmentSensitivity and SpecificityCoronary artery diseaseMyocardial perfusion imagingVentricular Dysfunction Left2d echocardiographyInternal medicineCoronary CirculationMedical imagingMedicineHumansRadiology Nuclear Medicine and imagingObserver VariationEjection fractionmedicine.diagnostic_testbusiness.industryGeneral Medicinemedicine.diseaseMyocardial contrast echocardiographyEuropeEchocardiographyCardiologyFemaleCardiology and Cardiovascular MedicinebusinessPerfusionKappaEuropean journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
researchProduct

Prospective evaluation of the macroscopic types and location of early Barrett’s neoplasia in 380 lesions

2007

The macroscopic appearance of early gastric cancers, classified according to the Japanese criteria, has been shown to be an important prognostic factor for local endoscopic therapy. No prospective data about the distribution of macroscopic types and their location in early Barrett's neoplasia are available, however. The present study was conducted to evaluate the clinical applicability of this macroscopic classification and to analyze the relative proportions of the different gross types in early Barrett's neoplasms and the correlation between the macroscopic classification and the stage or grade of differentiation.A total of 344 patients with 380 Barrett's neoplastic lesions who were refer…

Malemedicine.medical_specialtyEsophageal NeoplasmsBiopsyVideo RecordingSeverity of Illness IndexGastroenterologyEndoscopy GastrointestinalBarrett EsophagusInternal medicinemedicineCarcinomaHumansProspective StudiesIntestinal MucosaStage (cooking)EsophagusStomach cancerProspective cohort studyAgedNeoplasm StagingObserver VariationIntraepithelial neoplasiamedicine.diagnostic_testEsophageal diseasebusiness.industryGastroenterologyReproducibility of ResultsPrognosismedicine.diseaseEndoscopyEsophagectomymedicine.anatomical_structureDisease ProgressionFemalebusinessFollow-Up StudiesEndoscopy
researchProduct

Chromoendoscopy and narrow-band imaging compared with high-resolution magnification endoscopy in Barrett's esophagus.

2008

Background & Aims: The aim of this study was to compare magnified still images obtained with high-resolution white light endoscopy, indigo carmine chromoendoscopy, acetic acid chromoendoscopy, and narrow-band imaging to determine the best technique for use in Barrett's esophagus. Methods: We obtained magnified images from 22 areas with the 4 aforementioned techniques. Seven endoscopists with no specific expertise in Barretes esophagus or advanced imaging techniques and 5 international experts in this field evaluated these 22 areas for overall image quality, mucosal image quality, and vascular image quality. In addition, the regularity of mucosal and vascular patterns and the presence of abn…

Malemedicine.medical_specialtyEsophageal NeoplasmsHigh resolutionIndigo CarmineGastroenterologyChromoendoscopychemistry.chemical_compoundBarrett EsophagusEsophagusInternal medicinemedicineHumansEsophagusColoring AgentsAcetic AcidAgedAged 80 and overObserver VariationNarrow-band imagingMucous MembraneHepatologybusiness.industryGastroenterologyReproducibility of ResultsMiddle Agedmedicine.diseaseImage EnhancementMagnification endoscopymedicine.anatomical_structureIndigo carminechemistryBarrett's esophagusHigh Grade Intraepithelial NeoplasiaFemaleEsophagoscopyNuclear medicinebusinessPrecancerous ConditionsGastroenterology
researchProduct

On the number of measurement sites required to assess regional cerebral blood flow by laser-Doppler scanning during cerebral ischemia and reperfusion.

2001

The aim of this study was to determine whether the number of measurement sites affected the precision of regional cerebral blood flow (CBF) assessment by Laser-Doppler (LD). A simulation study was applied based on data obtained by scanning the cortex in 25 rats during baseline conditions, 15 min global cerebral ischemia and reperfusion. Random samples were repeatedly collected from 1 to 100 locations and deviations from the median of the entire CBF data pool (800 locations) were determined. Single location CBF measurements missed the true median by 24.8+/-2.2 LD-units (baseline conditions, n=100 simulations, mean+/-SEM), 2.7+/-0.6 LD-units (ischemia), and 31.9+/-2.4 LD-units (30th min reper…

Malemedicine.medical_specialtyIschemiaHemodynamicsBrain IschemiaInternal medicinemedicineLaser-Doppler FlowmetryAnimalsRats WistarObserver VariationMeasurement methodbusiness.industryGeneral NeuroscienceReproducibility of ResultsBlood flowLaser Doppler velocimetrymedicine.diseaseRatsCerebral blood flowAnesthesiaCerebrovascular CirculationReperfusion InjuryCardiologybusinessObserver variationJournal of neuroscience methods
researchProduct

Effect of observer experience in the differentiation between benign and malignant liver tumors after ultrasound contrast agent injection.

2009

OBJECTIVE: The purpose of this study was to assess the impact of the observer level of experience on the diagnostic performance of contrast-enhanced ultrasound imaging (CEUS) for differentiation between benign and malignant liver tumors. METHODS: From a computerized search, we retrospectively identified 286 biopsy-proven liver tumors (105 hepatocellular carcinomas, 48 metastases, 7 intra-hepatic cholangiocarcinomas, 33 liver hemangiomas, and 93 nonhemangiomatous benign lesions) in 235 patients (140 male and 95 female; mean age +/- SD, 56 +/- 11 years) who underwent CEUS after sulfur hexafluoride-filled microbubble injection. The digital cine clips recorded during the arterial (10-35 seconds…

Malemedicine.medical_specialtyLiver tumorObserver (quantum physics)media_common.quotation_subjectSulfur HexafluorideContrast MediaMalignancySensitivity and SpecificityMicrobubbleProfessional CompetencePhysiciansmedicineHumansContrast (vision)Radiology Nuclear Medicine and imagingPhospholipidsUltrasonographymedia_commonObserver VariationMicrobubblesRadiological and Ultrasound Technologybusiness.industryIncidenceLiver NeoplasmsUltrasoundReproducibility of ResultsMiddle Agedmedicine.diseaseItalyLiverInjections IntravenousLiver HemangiomaMicrobubbles; LiverFemaleRadiologybusinessKappaArterial phase
researchProduct