Search results for "Observer Variation"
showing 10 items of 156 documents
The shoulder medial rotation test: an intertester and intratester reliability study in overhead athletes with chronic shoulder pain.
2013
The purpose of this study was to examine intertester and intratester reliability of the shoulder medial rotation test (MRT) and reliability differences depending on examiner expertise.Seventeen athletes with chronic shoulder pain participated in the study. Four independent observers with different experience levels simultaneously rated MRT performance as "correct" or "incorrect," after a standardized assessment protocol, the same day (for intertester reliability) and in a 7-day interval (for intratester reliability).The intrarater reliability was admissible for 2 experts and one novice, with κ values ranging between 0.32 to 0.76 and poor for one novice (κ0). Interrater agreement for all 4 a…
Hepatic focal nodular hyperplasia: contrast-enhanced ultrasound findings with emphasis on lesion size, depth and liver echogenicity
2010
To correlate contrast-enhanced ultrasound (CEUS) findings of hepatic focal nodular hyperplasia (FNH) with lesion size, depth and liver echogenicity and to compare CEUS with baseline US. Two radiologists evaluated baseline US and CEUS examinations of 92 FNHs (mean size: 3.1 +/- 1.7 cm) in 71 patients (59 women and 12 men) to detect the "spoke-wheel" sign, central scar and feeding vessel. The FNHs were grouped and analysed by dimension, depth and liver echogenicity. At least one sign could be detected at CEUS in 27 out of 36 (75%) FNHs larger than 3 cm and in 17 out of 56 (30%) FNH measuring 3 cm or less (p 0.05) as well as between CEUS or baseline US/CD with regard to lesion size, depth or l…
Computed Virtual Chromoendoscopy for Classification of Small Colorectal Lesions: A Prospective Comparative Study
2007
Standard colonoscopy offers no reliable discrimination between neoplastic and nonneoplastic colorectal lesions. Computed virtual chromoendoscopy with the Fujinon intelligent color enhancement (FICE) system is a new dyeless imaging technique that enhances mucosal and vascular patterns. This prospective trial compared the feasibility of FICE, standard colonoscopy, and conventional chromoendoscopy with indigo carmine in low- and high-magnification modes for determination of colonic lesion histology.Sixty-three patients with 150 flat or sessile lesions less than 20 mm in diameter were enrolled. At colonoscopy, each lesion was observed with six different endoscopic modalities: standard colonosco…
Interexaminer reliability of low back pain assessment using the McKenzie method.
2002
STUDY DESIGN A test-retest design was used. OBJECTIVE To assess interexaminer reliability of the McKenzie method for performing clinical tests and classifying patients with low back pain. SUMMARY OF BACKGROUND DATA Clinical methods and tests classifying patients with nonspecific low back pain have been based mainly on symptom duration or extent of pain referral. The McKenzie mechanical diagnostic and classification approach is a widely used noninvasive, low-technology method of assessing patients with low back pain. However, little is known about the interexaminer reliability of the method, previous studies having yielded conflicting results. METHODS For this study, 39 volunteers with low b…
Reliability of the Dynamic Gait Index (Finnish version) in individuals with neurological disorders
2012
To produce a Finnish version of the Dynamic Gait Index (DGI) and establish its reliability in people with neurological disorders affecting balance.A consecutive sample of 33 participants in inter-rater and 30 participants in intra-rater sample were tested. The DGI was administered in two testing sessions 1-2 h apart. Reliability was assessed with the intra-class correlation coefficient (ICC), Bland-Altman 95% limits of agreement, coefficient of reproducibility (CR), and standard error of the mean (SEM).The instructions from the original DGI were preserved during the translation process with no need for cultural adaptations. The relative reliability of the total scores proved to be high in i…
Speckle myocardial imaging modalities for early detection of myocardial impairment in isolated left ventricular non-compaction
2009
Objective To examine the hypothesis that speckle myocardial imaging (SMI) modalities, including longitudinal, radial and circumferential systolic (s) and diastolic (d) myocardial velocity imaging, displacement (D), strain rate (SR) and strain (S), as well as left ventricular (LV) rotation/torsion are sensitive for detecting early myocardial dysfunction in isolated LV non-compaction (iLVNC). Design and results Twenty patients with iLVNC diagnosed by cardiac magnetic resonance (15) or echocardiography (5) were included. Patients were divided into two groups: ejection fraction (EF)>50% (n=10) and EF≤50% (n=10). Standard measures of systolic and diastolic function including pulsed wave tissue D…
Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
1996
The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…
Emergency radiology: straightening of the cervical spine in MDCT after trauma--a sign of injury or normal variant?
2016
To evaluate whether straightening of the cervical spine (C-spine) alignment after trauma can be considered a significant multidetector CT (MDCT) finding.160 consecutive patients after C-spine trauma admitted to a Level 1 trauma centre received MDCT according to Canadian Cervical Spine Rule and National Emergency X-Radiography Utilization Study indication rule; subgroups with and without cervical collar immobilization (CCI +/-) were compared with a control group (n = 20) of non-traumatized patients. Two independent readers evaluated retrospectively the alignment, determined the absolute rotational angle of the posterior surface of C2 and C7 (ARA C2-7) and grouped the results for lordosis (-1…
Left ventricular volume determination using Albunex.
1996
The aim of this study was to assess the ability of intravenous injection of Albunex to improve left ventricular volume determination in patients with various cardiac diseases. It is conceivable that the intravenous injection of microbubbles could improve echocardiographic left ventricular border delineation leading to improved interobserver variability. Echocardiograms were obtained during simultaneous intravenous injection of 0.08 and 0.12 ml/kg Albunex (four-chamber view). Within 6 hours after the recording of the contrast echocardiograms routine left heart angiography was performed. Volumes were measured using the slice method in native and contrast echocardiograms as well as in the angi…
Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests
2017
The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plo…