Search results for "Observer"
showing 10 items of 345 documents
The effect of body posture on long range time-to-contact estimation
2011
On Earth, gravity accelerates freely moving objects downward, whereas upward-moving objects are being decelerated. Do humans take internalised knowledge of gravity into account when estimating time-to-contact (TTC, the time remaining before the moving object reaches the observer)? To answer this question, we created a motion-prediction task in which participants saw the initial part of an object's trajectory moving on a collision course prior to an occlusion. Observers had to judge when the object would make contact with them. The visual scene was presented with a head-mounted display. Participants lay either supine (looking up) or prone (looking down), suggestive of the ball either rising…
Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced a…
2005
Aims To assess the agreement of left ventricular ejection fraction (LVEF) determinations from unenhanced echocardiography, contrast-enhanced echocardiography, magnetic resonance imaging (MRI), and cineventriculography as well as the inter-observer agreement for each method. Methods and results In 120 patients, with evenly distributed EF-groups (G 55, 35-55, L 35%), cineventriculography, unenhanced echocardiography with second harmonic imaging, and contrast echocardiography at tow mechanical index with iv administration of SonoVueR were performed. In addition, cardiac MRI at 1.5T using a steady-state free precession sequence was performed in a subset of 55 patients. On-site, and two blinded …
Multicenter Multireader Evaluation of an Artificial Intelligence-Based Attention Mapping System for the Detection of Prostate Cancer With Multiparame…
2020
OBJECTIVE. The purpose of this study was to evaluate in a multicenter dataset the performance of an artificial intelligence (AI) detection system with attention mapping compared with multiparametric MRI (mpMRI) interpretation in the detection of prostate cancer. MATERIALS AND METHODS. MRI examinations from five institutions were included in this study and were evaluated by nine readers. In the first round, readers evaluated mpMRI studies using the Prostate Imaging Reporting and Data System version 2. After 4 weeks, images were again presented to readers along with the AI-based detection system output. Readers accepted or rejected lesions within four AI-generated attention map boxes. Additio…
Early motor development and later language and reading skills in children at risk of familial dyslexia.
2005
Relationships between early motor development and language and reading skills were studied in 154 children, of whom 75 had familial risk of dyslexia (37 females, 38 males; at-risk group) and 79 constituted a control group (32 females, 47 males). Motor development was assessed by a structured parental questionnaire during the child's first year of life. Vocabulary and inflectional morphology skills were used as early indicators of language skills at 3 years 6 months and 5 years or 5 years 6 months of age, and reading speed was used as a later indicator of reading skills at 7 years of age. The same subgroups as in our earlier study (in which the cluster analysis was described) were used in th…
Intra-Rater Test-Retest Reliability of a Modified Child Functioning Module, Self-Report Version
2020
Determining disability prevalence is a growing area for population statistics, especially among young adolescents. The Washington Group on Disability Statistics is one source of reporting disabilities through functional difficulties. Yet, young adolescents self-reporting through this measure is in its infancy. The purpose of this study was to carry out an intra-rater test-retest reliability study on a modified set of items for self-reporting functional difficulties. Young adolescents (N = 74
Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis
2016
International audience; Objective: To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure.Methods: Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intraobserver and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data.Results: Twenty-seven p…
Using the Hemophilia Joint Health Score for assessment of children: Reliability of the Spanish version
2018
Introduction: Numerous measuring instruments for the evaluation of hemophilic arthropathy have been developed. One of the most used systems is the Hemophilia Joint Health Score (HJHS) given its sensitivity to clinical changes appearing in the joints because of recurrent hemarthrosis. Objective: Assessing the interrater reliability, using the Spanish version of the HJHS (version 2.1) in children with hemophilia. Design: Reliability study to assess the interrater reliability of the Spanish version of HJHS. Methods: A sample of 36 children aged 7–13 years diagnosed with hemophilia A or B was used. Two physiotherapists performed physical assessments with the Spanish version of the HJHS. Descrip…
Pulse wave transit time measurements of cardiac output in septic shock patients: a comparison of the estimated continuous cardiac output system with …
2015
Pôle EAMERSCT3Hors Enjeu; Background We determined reliability of cardiac output (CO) measured by pulse wave transit time cardiac output system (esCCO system; COesCCO) vs transthoracic echocardiography (COTTE) in mechanically ventilated patients in the early phase of septic shock. A secondary objective was to assess ability of esCCO to detect change in CO after fluid infusion. Methods Mechanically ventilated patients admitted to the ICU, aged > 18 years, in sinus rhythm, in the early phase of septic shock were prospectively included. We performed fluid infusion of 500ml of crystalloid solution over 20 minutes and recorded CO by EsCCO and TTE immediately before (T0) and 5 minutes after (T1) …
Echocardiographic reference ranges for normal left atrial function parameters results from the EACVI NORRE study
2018
International audience; Aims - To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function we…
CT angiography versus intraarterial digital subtraction angiography for assessment of aortoiliac occlusive disease.
1997
The purpose of this study was to evaluate the accuracy of CT angiography (CTA) with a single helical acquisition for assessment of stenoses and occlusions of the iliac arteries.In our prospective study, intraarterial digital subtraction angiography and IV CTA were performed from the suprarenal aorta to below the femoral bifurcation in 30 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were also obtained. The accuracy of CTA with and without analysis of axial images was determined.Sensitivity and specificity of CTA were 100% for iliac artery occlusions with a confidence interval 85-100% and 97-100%, respectively. When axial scans were interpret…