Search results for "Ocular"

showing 10 items of 1219 documents

Optical analysis to predict outcomes after implantation of a double intraocular lens magnification device.

2007

Purpose To analyze the effect of different optical parameters of the eye on the outcomes of implantation of a double intraocular lens (IOL) magnification device in patients with low vision. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The eye's refraction and magnification before and after surgery were evaluated using a theoretical eye model based on paraxial optics approximation. Four parameters on which refraction and magnification are dependent were evaluated: anterior chamber depth (ACD), axial length (AL), mean keratometry (Km), and the distance between the 2 implanted IOLs. The 4 variables were analyzed separately in the first stage. Next, different combi…

medicine.medical_specialtyOptics and PhotonicsBiometrygenetic structuresAnterior Chambermedicine.medical_treatmentMagnificationVision LowIntraocular lensEyeRefraction Ocularlaw.inventionOpticsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansIn patientPhysicsLenses IntraocularKeratometerbusiness.industryParaxial approximationModels TheoreticalMagnification deviceRefractioneye diseasesSensory SystemsLow visionOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

Preexisting Ocular Motor Palsy and Central Neuroaxial Block

2017

medicine.medical_specialtyPalsybusiness.industryOcular motorGeneral MedicineSurgery03 medical and health sciences0302 clinical medicineAnesthesiology and Pain MedicinePhysical medicine and rehabilitation030202 anesthesiologyBlock (telecommunications)medicinebusiness030217 neurology & neurosurgeryRegional Anesthesia and Pain Medicine
researchProduct

Ocular Motor Palsy After Spinal Puncture

2017

Abstract Ocular motor palsy is a rare but alarming complication of subarachnoid puncture. In order to better understand this condition, a literature search was performed in English of PubMed articles for cranial nerves III, IV, and VI palsies after spinal puncture. Sixty-five articles (dated 1930–2015) were identified, and 114 cases were obtained for analysis. Subarachnoid anesthesia was the most frequent cause (45.6%), with a higher incidence for females than males. The age of patients was 40.24 ± 13.35 years (age range, 6–71 years). The sixth cranial nerve was the most commonly involved (92.1%), with higher frequency in the right eye. Palsy onset started 7.30 ± 4.09 days after puncture. D…

medicine.medical_specialtyPalsybusiness.industryOcular motorIncidence (epidemiology)Cranial nervesGeneral MedicineExtraocular musclesSurgery03 medical and health sciencesAnesthesiology and Pain Medicinemedicine.anatomical_structure0302 clinical medicineSpinal PunctureFluid therapy030202 anesthesiologyAnesthesia030221 ophthalmology & optometryMedicineComplicationbusiness030217 neurology & neurosurgerySurvey of Anesthesiology
researchProduct

Developmental dyslexia and vision

2013

International audience; Developmental dyslexia affects almost 10% of school-aged children and represents a significant public health problem. Its etiology is unknown. The consistent presence of phonological difficulties combined with an inability to manipulate language sounds and the grapheme-phoneme conversion is widely acknowledged. Numerous scientific studies have also documented the presence of eye movement anomalies and deficits of perception of low contrast, low spatial frequency, and high frequency temporal visual information in dyslexics. Anomalies of visual attention with short visual attention spans have also been demonstrated in a large number of cases. Spatial orientation is als…

medicine.medical_specialtyPathologyocular motilitygenetic structuresmedia_common.quotation_subjectReviewNeglectOrientation (mental)readingPerceptionReading (process)Ophthalmologydyslexiamedicinemedia_commonbusiness.industryneglectDyslexiaEye movementCognitionmedicine.diseasePreferenceeye diseasesOphthalmology[ SCCO.NEUR ] Cognitive science/Neurosciencespatial representationbusinessCognitive psychologyClinical Ophthalmology (Auckland, N.Z.)
researchProduct

<p>Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens</p>

2019

Purpose To assess visual and refractive results after bilateral implantation of a trifocal intraocular lens (IOL) in patients with hyperopia. Methods In a retrospective nonrandomized study, 196 eyes of 98 patients had bilateral implantation of a trifocal IOL. The Barrett Universal II formula was used for IOL power calculation. Eyes were divided into two groups for their analysis: low-moderate, with IOL power ranging from 22 to 26 D, and high, with IOL power ranging from 25 to 34 D. Refractive error was used to assess predictability, and corrected distance visual acuity (CDVA) and uncorrected distance visual acuity values were used to assess efficacy and safety of the surgery. Results Six mo…

medicine.medical_specialtyRefractive errorDistance visual acuityVisual acuitygenetic structuresbusiness.industrymedicine.medical_treatmentSpherical equivalentIntraocular lensPhacoemulsificationmedicine.diseaseeye diseases03 medical and health sciencesOphthalmology0302 clinical medicineOphthalmology030221 ophthalmology & optometrymedicineIn patientsense organsmedicine.symptombusiness030217 neurology & neurosurgeryClinical Ophthalmology
researchProduct

Ergebnisse nach Implantation einer Worst Iris Claw Lens zur Korrektur der hohen Myopie

2001

Fragestellung. Ziel dieser prospektiven klinischen Studie war die Erfassung der Refraktion, des korrigierten Visus und des Vorderkammerreizzustandes nach Implantation einer Worst Iris Claw Lens zur Korrektur der hohen Myopie. Patienten und Methode. Von Dezember 1996 bis Februar 1999 wurde bei insgesamt 44 phaken Augen von 28 Patienten eine Worst Iris Claw Lens implantiert. Es folgte eine Nachbeobachtungszeit von 6 Wochen bzw. 6 Monaten. Ergebnisse. Das mittlere praoperative spharische Aquivalent betrug −17,35±3,57 dpt. Sechs Monate postoperativ lag die Refraktion bei 79% der Augen im Intervall von ±1,0 dpt von der Zielrefraktion entfernt. Der mittlere korrigierte Visus stieg von praoperativ…

medicine.medical_specialtyRefractive errorPolymethyl methacrylatebusiness.industrymedicine.medical_treatmentFollow up studiesIntraocular lensOcular refractionmedicine.diseaseVision disorderOphthalmologyOphthalmologymedicineProsthesis designmedicine.symptombusinessDer Ophthalmologe
researchProduct

Toric phakic intraocular lens

2003

Abstract Objective To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after implantation of Artisan toric phakic intraocular lenses (TPIOLs) for the correction of myopia or hyperopia with astigmatism. Design Prospective, nonrandomized, comparative (self-controlled) multicenter trial. Participants Seventy eyes of 53 patients (mean, 35 years; range, 22–59 years) with preoperative spherical equivalent between +6.50 and −21.25 diopters (D) and cylinder between 1.50 and 7.25 D. Methods Seventy eyes underwent implantation of a TPIOL with an optical zone of 5.0 mm (Artisan, Ophtec, Groningen, The Netherlands). The dioptric power of the intraocular lens…

medicine.medical_specialtyRefractive errorVisual acuitygenetic structuresKeratometerbusiness.industrymedicine.medical_treatmentIntraocular lensAstigmatismmedicine.diseasePhakic intraocular lenseye diseaseslaw.inventionToric lensOphthalmologylawOphthalmologymedicinesense organsmedicine.symptombusinessDioptreOphthalmology
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Biometric characterization of the anterior segment in a Sahrawi pediatric population

2013

Purpose: To examine the biometric characteristics of the anterior segment in a group of Sahrawi children. Methods: A total of 66 children (33 male and 33 female, aged between 8 and 13 years) participated in this prospective, observational study. The non-invasive Pentacam Scheimpflug imaging device was used to measure corneal thickness (CT) (at the thinnest corneal point), mean anterior (Km Ant) and posterior (Km Post) corneal radii, corneal volume (CVol), anterior chamber depth (ACD) and anterior chamber volume (ACVol). The contribution of age and gender to the various parameters was investigated. Results: CT values of the present group of Sahrawi children were 521.70 ± 3.92 m. Boys had thi…

medicine.medical_specialtyScheimpflug principlePediatric ocular biometryAge and genderlcsh:OphthalmologyOphthalmologylcsh:QC350-467MedicineGlaucoma preventionmedicine.diagnostic_testbusiness.industryPrevención de glaucomaScheimpflug imagingCorneal topographyCorneal thicknesslcsh:RE1-994Biometría ocular pediátricaGrosor cornealTopografía cornealOriginal ArticleCorneal topographysense organsImagen Scheimpflugbusinesslcsh:Optics. LightOptometryPediatric population
researchProduct

D2-dopamine receptor blockade modulates temporal resolution in goldfish.

2002

A possible effect of dopamine on the temporal resolution of goldfish was investigated in a behavioral, two-alternative, forced-choice procedure. Flicker fusion frequency (FFF) was measured before and after bilateral intravitreal injections of D1- or D2-dopamine receptor (D1-/D2-R) antagonists, or after depletion of retinal dopamine by bilateral intravitreal injections of the dopaminergic neurotoxin 6-hydroxydopamine (6-OHDA). Prior to drug injections, fish achieved FFFs of 33–39 Hz. A D1-R antagonist, SCH 23390, reduced FFF by about 12% (P > 0.1), whereas a D2 antagonist, sulpiride, reduced the relative FFF by 25% (P < 0.03). Depletion of retinal dopamine with 6-OHDA induced a gradual…

medicine.medical_specialtySerotoninTime FactorsTyrosine 3-MonooxygenasePhysiologyBiologyChoice BehaviorRetinaFlicker Fusionchemistry.chemical_compoundAdrenergic AgentsDopamineInternal medicineGoldfishmedicineNeurotoxinAnimalsOxidopamineSCH-23390Behavior AnimalAdaptation OcularReceptors Dopamine D2DopaminergicAntagonistRetinalBenzazepinesImmunohistochemistrySensory SystemsDopamine D2 Receptor AntagonistsEndocrinologychemistryDopamine receptorConditioning OperantDopamine AntagonistsSulpirideSulpiridemedicine.drugVisual neuroscience
researchProduct