Search results for "Ocular"
showing 10 items of 1219 documents
Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism
2015
Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…
Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up
2014
Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…
Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens
2011
PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
2009
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
Iris-fixated toric phakic intraocular lens for myopic astigmatism
2011
Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
2013
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Some physiological and psychological characteristics of myopic and non-myopic young men.
2009
As a part of a research project on the health and functional capacity of men at different ages a comparison of selected physiological and psychological characteristics of myopic and non-myopic 31–35 year-old men was made. The random sample studied consisted of 31 myopic and 100 non-myopic men. It was found that the body mass index and fat content were lower among the myopic than among the non-myopic. No significant differences were found in the elastic properties of skin, in blood pressure or in haematological assays studied between the groups. With respect to physical performance it was observed that the myopic had a higher aerobic capacity whereas there were no significant differences in …
Nine Loci for Ocular Axial Length Identified through Genome-wide Association Studies, Including Shared Loci with Refractive Error
2013
Refractive errors are common eye disorders of public health importance worldwide. Ocular axial length (AL) is the major determinant of refraction and thus of myopia and hyperopia. We conducted a meta-analysis of genome-wide association studies for AL, combining 12,531 Europeans and 8,216 Asians. We identified eight genome-wide significant loci for AL (RSPO1, C3orf26, LAMA2, GJD2, ZNRF3, CD55, MIP, and ALPPL2) and confirmed one previously reported AL locus (ZC3H11B). Of the nine loci, five (LAMA2, GJD2, CD55, ALPPL2, and ZC3H11B) were associated with refraction in 18 independent cohorts (n = 23,591). Differential gene expression was observed for these loci in minus-lens-induced myopia mouse …
An alternative clinical routine for subjective refraction based on power vectors with trial frames.
2016
PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …
Peripapillary Choroidal Thickness and Choroidal Area in Glaucoma, Ocular Hypertension and Healthy Subjects by SD-OCT.
2015
Background: The exact pathogenesis of open angle glaucoma and ocular hypertension remains unclear. Hemodynamic influences are discussed as potential risk factors and the choroid may play an important role in the pathogenesis of open angle glaucoma or ocular hypertension. The current study investigates peripapillary choroidal thickness and choroidal area in patients with open angle glaucoma, subjects with ocular hypertension and healthy subjects using spectral-domain OCT. It furthermore assesses the association between peripapillary choroidal thickness and age, central corneal thickness, refractive error and intraocular pressure. Patients and Methods: Prospectively recorded data of 213 eyes …