Search results for "Opacity"
showing 10 items of 73 documents
Flares from small to large: X-ray spectroscopy of Proxima Centauri with XMM-Newton
2003
(Abridged) We report results from a comprehensive study of the nearby M dwarf Proxima Centauri with the XMM-Newton satellite. We find strongly variable coronal X-ray emission, with flares ranging over a factor of 100 in peak flux. The low-level emission is found to be continuously variable. Several weak flares are characteristically preceded by an optical burst, compatible with predictions from standard solar flare models. We propose that the U band bursts are proxies for the elusive stellar non-thermal hard X-ray bursts suggested from solar observations. A very large X-ray flare was observed in its entirety, with a peak luminosity of 3.9E28 erg/s [0.15-10 keV] and a total X-ray energy of 1…
GJ 357 b: A Super-Earth Orbiting an Extremely Inactive Host Star
2020
Aims. In this paper we present a deep X-ray observation of the nearby M dwarf GJ 357 and use it to put constraints on the atmospheric evolution of its planet, GJ 357 b. We also analyse the systematic errors in the stellar parameters of GJ 357 in order to see how they affect the perceived planetary properties. Methods. By comparing the observed X-ray luminosity of its host star, we estimate the age of GJ 357 b as derived from a recent XMM-Newton observation (log Lx [erg s-1] = 25.73), with Lx-age relations for M dwarfs. We find that GJ 357 presents one of the lowest X-ray activity levels ever measured for an M dwarf, and we put a lower limit on its age of 5 Gyr. Using this age limit, we perf…
ARES. III. Unveiling the Two Faces of KELT-7 b with HST WFC3
2020
We present the analysis of the hot-Jupiter KELT-7b using transmission and emission spectroscopy from the Hubble Space Telescope (HST), both taken with the Wide Field Camera 3 (WFC3). Our study uncovers a rich transmission spectrum which is consistent with a cloud-free atmosphere and suggests the presence of H2O and H-. In contrast, the extracted emission spectrum does not contain strong absorption features and, although it is not consistent with a simple blackbody, it can be explained by a varying temperature-pressure profile, collision induced absorption (CIA) and H-. KELT-7 b had also been studied with other space-based instruments and we explore the effects of introducing these additiona…
Ray optics for absorbing particles with application to ice crystals at near-infrared wavelengths
2018
Abstract Light scattering by particles large compared to the wavelength of incident light is traditionally solved using ray optics which considers absorption inside the particle approximately, along the ray paths. To study the effects rising from this simplification, we have updated the ray-optics code SIRIS to take into account the propagation of light as inhomogeneous plane waves inside an absorbing particle. We investigate the impact of this correction on traditional ray-optics computations in the example case of light scattering by ice crystals through the extended near-infrared (NIR) wavelength regime. In this spectral range, ice changes from nearly transparent to opaque, and therefore…
Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.
2016
Purpose To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). Methods Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest’s periphery. Results The maxi…
Evaluation of the Ocular Tolerance of Three Tacrolimus Topical Pharmaceutical Preparations by Bovine Corneal Opacity and Permeability Test.
2015
Tacrolimus ocular preparations are commonly employed in autoimmune or inflammatory ocular disorders. However, currently there are not yet approved ocular formulations. Tacrolimus ocular side effects have been reported in clinical use, so the evaluation of different pharmaceutical preparations is mandatory. In this study, the local corneal tolerance and safety profile of three common tacrolimus 0.03% pharmaceutical preparations were evaluated.Corneal irritation and permeability of tacrolimus preparations were evaluated with the bovine corneal opacity and permeability (BCOP) test. Complementary corneal hematoxylin/eosin and immunohistochemistry staining for tight junctions and adherent juncti…
Direct Objective Quantification of Corneal Haze after Excimer Laser Photorefractive Keratectomy for High Myopia
1996
Purpose: The purpose of the study is to measure regional distribution differences in corneal haze after excimer laser photorefractive keratectomy for high myopia. Methods: The authors developed computerized gradient edge detectors with which were analyzed digitized anterior slit-lamp photographs of 40 eyes, an average of 21.0 plus or minus 14.5 weeks after photorefractive keratectomy for high myopia (−6 to −22 diopters). A treated area and an adjacent untreated area on the anterior corneal surface, each containing six regions, were quantified, and the difference was correlated with various parameters. Results: Mean differences between scarred and clear areas for haze grade 0.5, 1.0, 2.0, 3.…
Excimer laser photorefractive keratectomy for high myopia
1995
Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…
Measuring corneal clouding in patients suffering from mucopolysaccharidosis with the Pentacam densitometry programme
2013
Aim To identify a means to objectively measure corneal clouding in patients with mucopolysaccharidosis in a prospective controlled clinical trial. Methods Corneal haze was assessed by slit lamp examination and measured using the densitometry programme of the Pentacam, a rotating Scheimpflug camera in 33 mucopolysaccharidoses (MPS) patients and 32 controls. Results Pentacam measurements were available in 31 right and 31 left eyes of 32 patients and in 32 left and right eyes of 32 subjects in the control group. Slit lamp findings correlated very well with corneal density measurements (Spearman correlation right eye (OD)/left eye (OS)=0.782/0.791). MPS patients had higher density units (median…
Franceschetti Hereditary Recurrent Corneal Erosion
2011
To describe new affected individuals of Franceschetti's original pedigree of hereditary recurrent erosion and to classify a unique entity called Franceschetti corneal dystrophy.Observational case series.Slit-lamp examination of 10 affected individuals was conducted. Biomicroscopic examinations were supplemented by peripheral corneal biopsy in 1 affected patient with corneal haze. Tissue was processed for light and electron microscopy and immunohistochemistry was performed. DNA analysis was carried out in 12 affected and 3 nonaffected family members.All affected individuals suffered from severe ocular pain in the first decade of life, attributable to recurrent corneal erosions. Six adult pat…