Search results for "Ophthalmology"

showing 10 items of 1738 documents

2021

In the early 19th century, William H. Wollaston impressed the Royal Society of London with engravings of portraits. He manipulated facial features, such as the nose, and thereby dramatically changed the perceived gaze direction, although the eye region with iris and eye socket had remained unaltered. This Wollaston illusion can be thought of as head orientation attracting perceived gaze direction when the eye region is unchanged. In naturalistic viewing, the eye region changes with head orientation and typically produces a repulsion effect. Here we explore if there is a flip side to the illusion. Does the gaze direction also alter the perceived direction of the head? We used copies of the …

Visual perceptionHead (linguistics)media_common.quotation_subjectIllusionExperimental and Cognitive PsychologyGazeSensory SystemsVisual artsOphthalmologyPortraitArtificial IntelligenceOrientation (mental)Psychologymedia_commoni-Perception
researchProduct

Neuropsychological Approaches to Visually-Induced Vection: an Overview and Evaluation of Neuroimaging and Neurophysiological Studies

2020

Abstract Moving visual stimuli can elicit the sensation of self-motion in stationary observers, a phenomenon commonly referred to as vection. Despite the long history of vection research, the neuro-cognitive processes underlying vection have only recently gained increasing attention. Various neuropsychological techniques such as functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) have been used to investigate the temporal and spatial characteristics of the neuro-cognitive processing during vection in healthy participants. These neuropsychological studies allow for the identification of different neuro-cognitive correlates of vection, which (a) will help to unravel …

Visual perceptionResearch areasCognitive NeuroscienceMotion PerceptionSensationNeuroimagingExperimental and Cognitive PsychologyElectroencephalography050105 experimental psychology03 medical and health sciences0302 clinical medicineNeuroimagingmedicineHumansAttention0501 psychology and cognitive sciencesmedicine.diagnostic_test05 social sciencesNeuropsychologyElectroencephalographyLimitingNeurophysiologySensory SystemsOphthalmologyComputer Vision and Pattern RecognitionFunctional magnetic resonance imagingPsychology030217 neurology & neurosurgeryCognitive psychologyMultisensory Research
researchProduct

Image Content Enhancement Through Salient Regions Segmentation for People With Color Vision Deficiencies

2019

Color vision deficiencies affect visual perception of colors and, more generally, color images. Several sciences such as genetics, biology, medicine, and computer vision are involved in studying and analyzing vision deficiencies. As we know from visual saliency findings, human visual system tends to fix some specific points and regions of the image in the first seconds of observation summing up the most important and meaningful parts of the scene. In this article, we provide some studies about human visual system behavior differences between normal and color vision-deficient visual systems. We eye-tracked the human fixations in first 3 seconds of observation of color images to build real f…

Visual perceptiongenetic structureslcsh:BF1-990ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONExperimental and Cognitive Psychology02 engineering and technology050105 experimental psychologyArticlevisual saliencyArtificial IntelligenceColor mapping0202 electrical engineering electronic engineering information engineering0501 psychology and cognitive sciencesComputer visionSegmentationimage enhancementimage segmentationeye-trackingSettore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionibusiness.industry05 social sciencesEye movementImage segmentationFixation (psychology)Color vision deficienciesSensory Systemseye diseasesOphthalmologyeye movementslcsh:PsychologyHuman visual system modelEye tracking020201 artificial intelligence & image processingArtificial intelligencebusinessimagery
researchProduct

2015

Previewing distracters enhances the efficiency of visual search. Watson and Humphreys (1997) proposed that the preview benefit rests on visual marking, a mechanism which actively encodes distracter locations at preview and inhibits them afterwards at search. As Watson and Humphreys did, we used a letter-color search task to study constraints of visual marking in conjunction search and near-efficient single-feature search with single-colored and homogeneous distracter letters. Search performance was measured for fixed target and distracter features (block design) and for randomly changed features across trials (random design). In single-feature search there was a full preview benefit for bot…

Visual searchCommunicationVisual perceptionColor visionbusiness.industrySpeech recognitionRepetition primingSensory SystemsTask (project management)Conjunction (grammar)OphthalmologyFeature (computer vision)businessPsychologyBlock (data storage)Journal of Vision
researchProduct

Desprendimiento del vítreo posterior y vitreolisis farmacológica: la nueva era de la vitrectomía enzimática

2007

Vitreous DetachmentOphthalmologymedicine.medical_specialtybusiness.industrymedicine.medical_treatmentOphthalmologymedicineVitrectomybusinessFibrinolysinmedicine.drug
researchProduct

Rituximab in refractory Vogt-Koyanagi-Harada disease.

2011

Introduction Vogt–Koyanagi–Harada (VKH) prognosis depends on early recognition and treatment; chronic disease may be developed when either delayed or inadequate treatment is performed, whereas other cases despite correct treatment are refractory to different drugs and also become chronic. We report a case of refractory VKH controlled with rituximab treatment. Case report A 41-year-old female with painful visual loss and headache was examined. (VA 0.4 in RE and hand movements (HM) in LE). Retinal examination demonstrated multiple serous retinal detachments in both eyes. High-dose oral steroids were started, followed by progressive tapering of prednisone. New acute anterior and posterior rela…

Vogt–Koyanagi–Harada diseasePathologymedicine.medical_specialtybusiness.industryBrief ReportDiseaseImmunommodulatorsmedicine.diseaseDermatologyeye diseasesChronic VKHOphthalmologySerous fluidInfectious DiseasesRefractoryPrednisonemedicineAdalimumabRituximabmedicine.symptombusinessRituximabTinnitusmedicine.drugJournal of ophthalmic inflammation and infection
researchProduct

Successful Topical Application of Caspofungin in the Treatment of Fungal Keratitis Refractory to Voriconazole

2010

Fungal keratitis is an important ophthalmic problem because it leads to corneal blindness and sometimes to loss of the eye.1,2 There is no agreed protocol for the treatment of suspected fungal keratitis. Topical and oral voriconazole have now been reported to be effective.3 However, some cases do not respond to this treatment. New antifungal agents such as caspofungin acetate, 0.5%, are promising alternatives

Voriconazolemedicine.medical_specialtybusiness.industryEye diseaseFongs patògensmedicine.diseasecorneal ulcerCaspofungin AcetateKeratitisSurgeryOphthalmologychemistry.chemical_compoundRefractorychemistrymedicineFungal keratitisCaspofunginbusinessmedicine.drugArchives of Ophthalmology
researchProduct

Comparison of higher order aberrations measured by NIDEK OPD-Scan dynamic skiascopy and Zeiss WASCA Hartmann-Shack aberrometers.

2008

<h4>PURPOSE</h4><p>To compare the measurement of wavefront aberrations in non-cyclopleged human eyes with Hartmann-Shack and dynamic skiascopy wavefront analyzers.</p> <h4>METHODS</h4><p>Eighty eyes of 40 healthy young adults (19 men, 21 women; mean age 20.8±2.5 years) with refractive errors ranging from +1.50 to –9.75 diopters (D) sphere and up to 1.75 D cylinder (mean spherical equivalent refraction –2.12±2.69 D) were examined with the Zeiss/Meditec WASCA and NIDEK OPD-Scan wavefront analyzers and with the Nippon SRW5000 binocular, open-field autorefractor without the instillation of antimuscarinic agents. Three measurements were taken with each s…

WavefrontAdultMalegenetic structuresbusiness.industrymedicine.medical_treatmentReproducibility of ResultsClinical settingsDiagnostic Techniques OphthalmologicalRefraction OcularRefractive Errorseye diseasesOphthalmologyAberrations of the eyeOpticsRefractive surgerymedicineOptometryHumansSurgeryFemalebusinessNatural stateMathematicsWavefront analysisJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

In vitro optical performance of a new aberration-free intraocular lens

2014

To assess the optical performance of the new EnVista intraocular lens (IOL). Four aspheric IOLs were evaluated; the new EnVista is one amoung them. This IOL, similarly to the Z-Flex HB and the Bi-Flex 1.8 667AB ones, has a neutral aspheric design, whereas the fourth IOL under test (AcrySof IQ IOL SN60WF) presents a negative spherical aberration (SA). The IOL’s aberration patterns were measured in vitro, by setting them up on an optical bench. From these aberration-pattern data, the modulation transfer function (MTF), the average modulation values, and the points spread function (PSF) were calculated. Furthermore, in order to assess the potential optical quality that these IOLs would yield o…

WavefrontLenses Intraocularmedicine.medical_specialtyOptics and PhotonicsMaterials scienceCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentIntraocular lensequipment and suppliesProsthesis Designeye diseasesOptical qualityOphthalmologySpherical aberrationmedicine.anatomical_structureCorneaOphthalmologyOptical transfer functionLaboratory StudymedicineProsthesis designHumanssense organsCorneal Wavefront Aberration
researchProduct

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

2014

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

WavefrontOptics and PhotonicsPhakic Intraocular LensesMaterials sciencePolymersApertureZernike polynomialsbusiness.industryStrehl ratioPupilProsthesis DesignRefraction OcularPhakic intraocular lensSensory SystemsRoot mean squareOphthalmologySpherical aberrationsymbols.namesakeOpticssymbolsHumansSurgeryCollagenbusinessDioptreJournal of Cataract and Refractive Surgery
researchProduct