Search results for "Optical Coherence"
showing 10 items of 223 documents
Comparison of Macular Thickness in Patients with Keratoconus and Control Subjects Using the Cirrus HD-OCT
2014
Purpose.The aim of the present study was to compare macular thickness in patients with keratoconus (KC) with macular thickness in healthy subjects.Subjects and Methods.Twenty-six patients with KC and 52 control subjects were included. The macular structure was evaluated using a Zeiss Cirrus HD-OCT. The scan pattern used was 512 × 128, which covers an area of approximately 6 × 6 mm of the retina. The cube volume was assessed as well as macular thickness in each of the 9 sectors defined by the software.Results.The mean signal strength was significantly lower in the KC group (mean 8.4, range 6–10) compared with the control group (mean 9.7, range 7–10),P<0.0001(unpairedt-test). There were no…
Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery
2009
PURPOSE To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS In the biaxial group, median foveal thickness changed from 160 microm preoperatively to 168 microm 8 weeks postoperatively (p=0.018…
Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.
2015
Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
2009
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
Peripapillary Choroidal Thickness and Choroidal Area in Glaucoma, Ocular Hypertension and Healthy Subjects by SD-OCT.
2015
Background: The exact pathogenesis of open angle glaucoma and ocular hypertension remains unclear. Hemodynamic influences are discussed as potential risk factors and the choroid may play an important role in the pathogenesis of open angle glaucoma or ocular hypertension. The current study investigates peripapillary choroidal thickness and choroidal area in patients with open angle glaucoma, subjects with ocular hypertension and healthy subjects using spectral-domain OCT. It furthermore assesses the association between peripapillary choroidal thickness and age, central corneal thickness, refractive error and intraocular pressure. Patients and Methods: Prospectively recorded data of 213 eyes …
Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography
2019
ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …
OCT is not useful for detection of minimal diabetic retinopathy in type 1 diabetes.
2009
Optical coherence tomography (OCT) has been proven useful in measuring retinal thickness (RT) in patients with diabetes, although with discordant results in different studies. We examined RT in patients with type 1 diabetes (T1D) with or without minimal diabetic retinopathy (MDR) to test whether OCT is able to identify early retinal changes and potential correlations with metabolic parameters. RT of 102 patients with T1D (53 females, 49 males, aged 27.03 +/- 7.4 years) and of 42 healthy controls was examined, with analysis of nine different sectors (fovea, four pericentral and four peripheral sectors). According to the results of basal fundus photography, patients were divided into two grou…
Coronary embolism in a young patient with nonbacterial thrombotic endocarditis related to antiphospholipid syndrome
2020
myocardial infarction
Assessment of corneal thickness and tear meniscus during contact-lens wear
2014
To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…