Search results for "Optical Coherence"
showing 10 items of 223 documents
Biodegradable collagen matrix implant versus mitomycin-C in trabeculectomy: five-year follow-up.
2015
Background Clinical studies comparing trabeculectomy augmented with Ologen implant (OLO) versus trabeculectomy plus mitomycin-C (MMC) show contradictory results. To obtain long-term data, we report an extended 5-year follow-up trial evaluating the safety and efficacy of OLO as adjuvant compared to low-dosage MMC in trabeculectomy. Methods Forty glaucoma patients (40 eyes) assigned to trabeculectomy with MMC or Ologen. Primary outcome: target IOP at ≤21, ≤17 and ≤15 mmHg; complete and qualified success endpoint rates. Secondary outcomes: visual acuity (VA), mean deviation (MD), bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain OCT (SD-OCT) bleb examination;…
Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial
2011
AIM: To verify the safety and efficacy of Ologen (OLO) implant as adjuvant compared with low-dosage mitomycin-C (MMC) in trabeculectomy. METHODS: This was a prospective randomized clinical trial with a 24-month follow-up. Forty glaucoma patients (40 eyes) were assigned to trabeculectomy with MMC or OLO. Primary outcome includes target IOP at ≤21, ≤17, and ≤15 mm Hg; complete (target IOP without medications), and qualified success (target IOP regardless of medications). Secondary outcomes include bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain optical coherence tomography (SD-OCT) examination; number of glaucoma medications; and frequency of postoperative…
Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes
2009
Purpose: To describe a method to measure corneal volume from topography and pachymetry, and test its clinical use on a sample of healthy human subjects and a case of circumscribed posterior keratoconus. Methods: Corneal curvature (PCT 200® corneal topography system; Optopol Technology SA, Zawiercie, Poland) and ultrasonic topographic pachometry on 25 points (Ophthasonic ® A-Scan/Pachometer III; Teknar Inc., St Louis, MO, USA) were measured on each of 12 young healthy corneas and one cornea suffering from circumscribed posterior keratoconus. Topography and pachymetry data were used to calculate the coordinates for the corresponding points on the posterior surface of the cornea. TableCurve 3D…
Assessment of anterior segment measurements using a high-resolution imaging device
2020
To assess the repeatability of several anterior segment parameters obtained with swept-source optical coherence tomography (SS-OCT).We measured 5-times consequently several parameters in 69 eyes using the ANTERION SS-OCT. White-to-white (WTW), angle-to-angle (ATA), spur-to-spur (STS), and lens vault distances were measured in the horizontal- and vertical-meridian. Anterior-chamber-angle (ACA), scleral-spur-angle (SSA), angle-opening-distance (AOD), and trabecular-iris-space-area (TISA) were measured at 500 and 750 μm for the superior-, nasal-,inferior-, and temporal-quadrants. Intrasubject standard deviation (Sw),coefficient of variation (CoV), coefficient of repeatability (CoR), and intrac…
Irregularity of the posterior corneal surface after curved interface femtosecond laser-assisted versus microkeratome-assisted descemet stripping auto…
2013
During donor tissue preparation for Descemet stripping automated endothelial keratoplasty (DSAEK), either microkeratome or femtosecond laser can be used for intrastromal cutting. We compared morphological and functional outcomes after DSAEK using both cutting techniques.In this retrospective study, 22 uneventful DSAEK surgeries were reviewed. Eight donor corneas were prepared for DSAEK using the VisuMax femtosecond laser (Carl Zeiss Meditec AG, Jena, Germany). Fourteen corneas were processed using an Amadeus II microkeratome (Ziemer Ophthalmic Systems AG, Port, Switzerland). The postoperative best spectacle-corrected visual acuity was measured. Furthermore, corneal optical coherence tomogra…
Ocular Phenotype of Relaxin Gene Knockout (Rln-/-) Mice
2020
Purpose: To test if relaxin deficiency affects ocular structure and function we investigated expression of relaxin (Rln) and RXFP receptors (Rxfp1, Rxfp2), and compared ocular phenotypes in relaxin gene knockout (Rln-/- ) and wild type (Rln+/+ ) mice. Materials and Methods: Rln, Rxfp1 and Rxfp2 mRNA expression was detected in ocular tissues of Rln+/+ mice using RT-PCR. The eyes of 11 Rln-/- and 5 Rln+/+ male mice were investigated. Corneal and retinal thickness was assessed using optical coherence tomography. Intraocular pressure was measured using a rebound tonometer. Retinal, choroidal and sclera morphology and thickness were evaluated histologically. Eyes were collected and fixed for imm…
Characteristics and pathologies of the vitreo‐macular interface—results from the Gutenberg Health Study
2019
Purpose We aimed to determine the prevalence of characteristics and pathologies of the vitreo-macular interface within the general population. Methods The Gutenberg Health Study is a population-based study in Germany, including an ophthalmological examination with refraction, biometry and optical coherence tomography (OCT) imaging. Characteristics of the vitreo-macular interface were graded on volume scans including visibility of an epiretinal membrane, full-thickness macular hole, lamellar hole and pseudohole. Overall and age-specific prevalences including 95% confidence intervals [95%-CI] were calculated. Association analyses were conducted to determine systemic and ocular factors that ar…
TREATMENT OF PERSISTENTLY OPEN MACULAR HOLES WITH HEAVY SILICONE OIL (DENSIRON 68) VERSUS C2F6. A PROSPECTIVE RANDOMIZED STUDY
2016
Abstract PURPOSE: To compare the efficacy of a mixture of silicone oil and perfluorohexyloctane (Densiron 68) with C2F6 gas endotamponade in the retreatment of persistently open full-thickness macular holes. METHODS: In this prospective randomized study, 21 consecutive patients who were unsuccessfully operated on for large idiopathic full-thickness macular hole were randomly assigned to undergo a second vitrectomy with 20% perfluoroethane gas (C2F6, Group A) or with Densiron 68 tamponade (Group B). PRIMARY OUTCOMES: Endpoint (12 months) full-thickness macular hole closure rate by spectral domain optical coherence tomography and logMAR corrected distance visual acuity. SECONDARY OUTCOMES: po…
Kinetic and static perimetry after 16 years and additional OCT-A analysis in eyes with long-lasting optic disc drusen
2021
The aim of the study is to evaluate the progression of visual field (VF) defects over 16 years of observation and to assess abnormalities in vessels and retinal nerve fibre layer (RNFL) thickness in patients with optic disc drusen (ODD). Both static automated perimetry (SAP) and semi-automated kinetic perimetry (SKP) were performed in 16 eyes of 8 patients (mean age 54 years) with ODD among 26 eyes of 13 patients examined 16 years before. The area of I2e, I4e, III4e, and V4e isopters was measured in deg2. The MD and PSD parameters were estimated using SAP. Optical coherence tomography angiography (OCT-A) was additionally performed in 16 ODD eyes and 16 eyes of 8 healthy subjects to estimate…
Comparison of Foveal, Macular, and Peripapillary Intraretinal Thicknesses Between Autism Spectrum Disorder and Neurotypical Subjects
2017
Purpose To compare thicknesses of intraretinal layers segmented by spectral-domain optical coherence tomography (SD-OCT) between autism spectrum disorder (ASD) and neurotypical (NT) individuals. Methods We performed 2 scans on 108 eyes from 54 participants (27 high-functioning ASD and 27 age- and sex-matched NT subjects): macular fast volume and peripapillary retinal nerve fiber layer (pRNFL). Macula was automatically segmented. The mean foveal and macular thickness of nine different layers and the thickness of nine pRNFL sectors were considered. Data from the right and left eyes were averaged for each participant. The results were compared between the ASD and NT groups. Associations betwee…