Search results for "Optical filter"
showing 10 items of 57 documents
Stable Optically Generated RF Signals from a Fibre Mode-Locked Laser
2010
Phase stability of RF signals obtained by two-mode filtering of a fibre mode-locked laser is analyzed. Time jitter is shown to be constant with selected mode spacing, confirming the scheme capability for generating stable RF signals up to extremely-high frequency.
Remote photoplethysmography for skin perfusion monitoring using narrowband illumination
2019
The purpose of this study was to determine potential of remote photoplethysmography for skin perfusion monitoring, using 540 nm narrowband and 530 nm broadband illuminations. The alterations of cutaneous circulation were produced by topical skin heating protocol. The setup comprises of 530 nm LED light source and two identical cameras operated simultaneously: one equipped with narrowband optical filter (CWL=540nm), and another without filter. Results demonstrate the typical heating test response curve- comprising first peak, nadir and plato phase, which were significantly different in narrowband and broadband illumination. It was concluded that selection of optimal light source parameters i…
Wearable, Fiber-less, Multi-Channel System for Continuous Wave Functional Near Infrared Spectroscopy Based on Silicon Photomultipliers Detectors and …
2019
Development and in-vivo validation of a Continuous Wave (CW) functional Near Infrared Spectroscopy (fNIRS) system is presented. The system is wearable, fiber-less, multi-channel (16×16, 256 channels) and expandable and it relies on silicon photomultipliers (SiPMs) for light detection. SiPMs are inexpensive, low voltage and resilient semiconductor light detectors, whose performances are analogous to photomultiplier tubes (PMTs). The advantage of SiPMs with respect to PMTs is that they allow direct contact with the scalp and avoidance of optical fibers. In fact, the coupling of SiPMs and light emitting diodes (LEDs) allows the transfer of the analog signals to and from the scalp through thin …
Real-time and low-cost sensing technique based on photonic bandgap structures
2011
[EN] A technique for the development of low-cost and high-sensitivity photonic biosensing devices is proposed and experimentally demonstrated. In this technique, a photonic bandgap structure is used as transducer, but its readout is performed by simply using a broadband source, an optical filter, and a power meter, without the need of obtaining the transmission spectrum of the structure; thus, a really low-cost system and real-time results are achieved. Experimental results show that it is possible to detect very low refractive index variations, achieving a detection limit below 2 x 10(-6) refractive index units using this low-cost measuring technique. (C) 2011 Optical Society of America[
Nonlinear spectral compression in fibre as a power-limiting device
2017
Spectral compression (SC) by self-phase modulation in optical fibre has been known for a long time and has since been reported for various parameters [1]. In this paper, we analyse the impact of amplitude fluctuations and a degraded optical signal-to-noise ratio (OSNR) of the seed pulses on the SC process by means of extensive nonlinear Schrodinger equation numerical simulation. Remarkably, our results show that the SC is rather stable against these pulse degradation factors, thereby revealing its potential for use in the context of optical regeneration of intensity-modulated signals. We therefore propose an optical scheme combining SC with an optical bandpass filter (OBPF) centred at the c…
Interferometric Phase Retrieval in Optical Transient Detection
2021
A transient detection imaging system (TDI), also known as optical novelty filter, is an adaptive interferometric device that detects temporal changes in a scene while suppressing its static parts. Removal of background improves contrast and helps visualizing and measuring intensity and phase. Following the first TDI proposal by Cudney et al. [1] , most TDI systems are based on photorefractive two-wave mixing [2] . Previous works rely on conventional intensity measurements, where partial information about input signal phase changes are obtained by previous calibration using an input phase-output intensity transfer function of the particular system.
Filter performance parameters for vectorial high-aperture wave fields.
2008
Performance parameters have been presented that can be used to compare the focusing performance of different optical systems, including the effect of pupil filters. These were originally given for the paraxial case and recently extended to the high-aperture scalar regime. We generalize these parameters to the full vectorial case for an aplanatic optical system illuminated by a plane-polarized wave. The behavior of different optical systems is compared.
The optical/UV filters for the EPIC experiment
1998
EPIC, the European Photon Imaging Cameras is an experiment based on cooled CCDs on board the ESA X-ray Multi Mirrors satellite due to be launched in 1999. Since CCD's are sensitive to radiation other than X-rays, namely Optical and UV light, filters are necessary to prevent this radiation from reaching the detector sensitive area. Three types of filters were developed, to be used alternatively depending on target source. Here we report on the medium and thin filters developed by MOXTEK Inc. in Orem, Utah, while the thick ones, developed at the Max-Planck-Institut fur Extraterrestrische Physik (MPE, Germany) have been described elsewhere. The two filters, described here, have a 1600 /spl Ari…
All-fiber incoherent frequency-to-time mapping method for microwave signal generation with baseband transmission and multicasting support
2008
We present a proof-of-principle experiment for achieving simultaneous distribution of baseband radio-frequency data and up-conversion with broadcasting support over a passive optical network. The technique is based on an incoherent frequency-to-time mapping method for pulse shaping. Specifically, we synthesize the spectral density function of sliced ASE noise from an EDFA with a periodic Mach-Zehnder fiber interferometer optical filter. By using external intensity modulation combined with propagation in an optical fiber, after photodetection, the resultant averaged temporal pulse profile resembles the shape of the incoherent source. The photodetected signal contains both the baseband data a…
Incoherent photonic techniques for RF-AWG
2010
The capabilities for RF-AWG in terms of waveform fidelity for three different incoherent photonic methods are revised and discussed: incoherent frequency-to-time mapping, incoherent MWP filtering with N discrete taps, and multi-wavelength pulse compression.