Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye stu…
2007
Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…
Accommodative stimulus-response curves to low-pass filtered natural images
2018
To assess how the monocular steady-state accommodative stimulus-response curve is modified when viewing low-pass filtered natural images. Eighteen adult subjects participated in the study. The accommodative stimulus-response curve was objectively assessed by means of a Hartmann-Shack wavefront sensor. Measurements were taken at different accommodative demands. Target images were low-pass filtered versions of a natural image that were obtained applying different digital spatial filters that limited the spatial frequency content of the natural image. Cutoff spatial frequencies were set at 30, 21, and 15 cycles per degree (cy/deg). Mean data obtained for each target were fitted to linear model…
An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers
2021
This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Ocular surface parameter...
Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery
2009
PURPOSE To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS In the biaxial group, median foveal thickness changed from 160 microm preoperatively to 168 microm 8 weeks postoperatively (p=0.018…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
2013
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery
2013
To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…
Image quality and visual performance in the peripheral visual field following photorefractive keratectomy.
2002
ABSTRACT PURPOSE: A theoretical and experimental study was performed to assess the possible effects of photorefractive keratectomy (PRK) on retinal image quality and thresholds in the peripheral visual field. METHODS: Simple optical calculations suggest that although the quality of the retinal image at the fovea of the postoperative PRK eye may be comparable to that in an emmetropic eye, images in the peripheral field may be markedly worse, since peripheral ray bundles may pass partly through ablated and partly through unablated cornea, giving a simultaneous-vision bifocal effect. This would be expected to create an annular zone of confusion, so that light from two different directions in o…
Effect of phenylephrine on static and dynamic accommodation
2018
Purpose We tested the hypothesis that changes in accommodation after instillation of Phenylephrine Hydrochloride (PHCl) observed in some studies could be caused by changes in optics. Methods We performed two experiments to test the effects of PHCl on static and on dynamic accommodation in 8 and 6 subjects, respectively. Objective wavefront measurements were recorded of the static accommodation response to a stimulus at different distances or dynamic accommodation response to a sinusoidally moving stimulus (between 1 and 3 D of accommodative demand at 0.2 Hz). The responses were characterized using two methods: one that takes into account the mydriatic optical effects on the accommodation pr…
The progression of myopia from its onset at age 8-12 to adulthood and the influence of heredity and external factors on myopic progression. A 23-year…
2013
Purpose To examine myopic progression and factors connected with myopic progression. Methods Myopic schoolchildren, with no previous spectacles, 119 boys and 121 girls, were recruited during 1983–1984 to a randomized 3-year clinical trial of bifocal treatment of myopia with a subsequent 20-year follow-up. Participants' mean age at Baseline was 10.9, ranging from 8.7 to 12.8 years. An ophthalmological examination was carried out annually for 3 years and twice thereafter at ca. 10-year intervals. Additional refraction values were received from prescriptions issued by different ophthalmologists and opticians. Altogether, 1915 refraction values were available. Reading distance and accommodation…