Search results for "Optometry"
showing 10 items of 812 documents
Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation
2003
Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…
Prevalence of corneal astigmatism before cataract surgery.
2008
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…
Results of an Adaptive Surgical Approach for Managing Late Onset Hypotony After Trabeculectomy With Mitomycin C.
2018
OBJECTIVES The objective of this study is to investigate the results of an adaptive approach of bleb revision surgery for late onset hypotony after trabeculectomy with mitomycin C because of bleb leakage and/or scleral melting. METHODS A total of 29 eyes of 27 patients, aged 63.8±11.7 years with hypotony maculopathy [intraocular pressure (IOP), ≤6 mm Hg] because of late onset bleb leakage and/or scleral melting after trabeculectomy with mitomycin C in which minimally invasive transconjunctival suturing of the scleral flap was impossible were enrolled in this retrospective interventional case series. External bleb leakage was seen in 16 eyes, 11 eyes suffered from scleral melting. Because of…
Refractive lens exchange with the Acri. Twin asymmetric diffractive bifocal intraocular lens system
2009
PURPOSE To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses. METHODS The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at …
Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact…
2020
Purpose To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. Methods A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 +/- 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-…
Response of the aging eye to first day of modern material contact lens wear
2018
Objectives: To investigate the ocular surface of an aged population wearing a daily disposable contact lens over their first day of wear. Methods: Forty eyes from forty presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA) and ocular surface aberrations (total higher order root means square (RMS)) were assessed at baseline (t0), at 20 minutes (t1) and after 8 hours (t2) of wear. Fluorescein corneal and conjunctival staining and tear break up time (TBUT) were performed at t0 and t2. Results: No statistically significant changes were found between t0, t1 and t2 for TMA, and between t0 and t2 for fluorescein corneal and conjunctival staining. TBUT…
Ranibizumab for Branch Retinal Vein Occlusion Associated Macular Edema Study (RABAMES): six-month results of a prospective randomized clinical trial
2014
Purpose To compare standard-of-care grid laser photocoagulation versus intravitreal ranibizumab (IVR) versus a combination of both in the treatment of chronic (>3 months) macular oedema secondary to branch retinal vein occlusion. Methods Prospective, randomized, multicentre clinical trial. Thirty patients with a best-corrected visual acuity (BCVA) between 20/320 and 20/40 were randomized 1:1:1 to receive grid laser or three monthly injections of 0.5 mg IVR or both followed by 3 months of observation. Results Mean change from baseline BCVA at month 6 was +2 letters [laser; 0.04 logMAR, 95% confidence interval (−0.17; 0.25)], +17 letters [IVR; 0.34 (0.19; 0.5)] and +6 letters [combination; 0.…
Assessment of corneal morphological changes induced by the use of daily disposable contact lenses.
2015
To assess the effect of different disposable soft contact lenses upon corneal thickness, and upon anterior and posterior corneal curvatures using a dual-Scheimpflug imaging based device.Twenty-eight young, healthy subjects wore four different types of daily disposable soft contact lenses on four different days: Dailies Total1, Proclear 1 Day, Clariti 1-Day and 1-Day Acuvue Moist. The lenses had different material and water content. Pachymetry maps and keratometry values were obtained using the Galilei G4 twice a day: one before putting the lens on and one after an eight-hour period of contact-lens wear. Measurements were also recorded without any contact lenses being worn during a day.Clari…
Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…
2010
Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …
Influence of different types of astigmatism on visual acuity
2016
[EN] Purpose To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. Methods The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were also simulated on the same eyes for comparison. VA was measured in each case and the results, expressed in logMAR units, were represented against of the modulus of the dioptric power vector (blur strength). Results LogMAR VA varies in a linear fashion with increasing astigmatic blur, being the slope o…