Search results for "Optometry"
showing 10 items of 812 documents
Corneal Aberrations in Former Preterm Infants: Results From The Wiesbaden Prematurity Study
2017
Purpose To compare corneal aberrations in former preterm infants to that of full-term infants. Methods A prospective cross-sectional study was carried out measuring the corneal shape with Scheimpflug imaging in former preterm infants of gestational age (GA) ≤32 weeks and full-term infants with GA ≥37 weeks now being aged between 4 to 10 years. The main outcome measures were corneal aberrations including astigmatism (Zernike: Z2-2; Z22), coma (Z3-1; Z31), trefoil (Z3-3; Z33), spherical aberration (Z40) and root-mean square of higher-order aberrations (RMS HOA). Multivariable analysis was performed to assess independent associations of gestational age groups and of retinopathy of prematurity …
Prospective visual evaluation of apodized diffractive intraocular lenses
2006
To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…
Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.
2011
PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…
Prospective study of the Acri.LISA bifocal intraocular lens
2007
To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…
Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation
2007
Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…
Comparison of two artificial tear formulations for dry eye through high‐resolution optical coherence tomography
2011
Purpose: The aim was to determine the efficacy of two artificial eye-drop formulations by analysing the lower tear film meniscus volume through a commercial high-resolution spectral-domain optical coherence tomographer. Methods: Twenty dry eye patients (12 men, eight women, aged 57.5 ± 8.4 years) with refractive errors from -2.50 to +0.75 D (mean -1.34 ± 1.02 D) and cylinders lower than 1.00 D were examined. Tear meniscus volume was measured before, immediately after and 10, 30 and 60 minutes after instillation using the Copernicus high-resolution spectral-domain optical coherence tomographer (Optopol Tech SA, Zawiercie, Poland). Volume was calculated from the local area obtained from tom…
TFOS DEWS II Sex, Gender, and Hormones Report
2017
One of the most compelling features of dry eye disease (DED) is that it occurs more frequently in women than men. In fact, the female sex is a significant risk factor for the development of DED. This sex-related difference in DED prevalence is attributed in large part to the effects of sex steroids (e.g. androgens, estrogens), hypothalamic-pituitary hormones, glucocorticoids, insulin, insulin-like growth factor 1 and thyroid hormones, as well as to the sex chromosome complement, sex-specific autosomal factors and epigenetics (e.g. microRNAs). In addition to sex, gender also appears to be a risk factor for DED. âGenderâ and âsexâ are words that are often used interchangeably, but the…
Branch retinal vein occlusion associated with the 20210 G-to-A prothrombin variant.
2000
Purpose To describe a case of branch retinal vein occlusion (BRVO) in a patient who tested positive for the 20210 A allele of the prothrombin (PT) gene. Methods A 48-year-old man had visual loss in the right eye secondary to BRVO confirmed by ophthalmoscopy and fluorescein angiography. His medical history was not remarkable for common risk factors for retinal occlusive diseases. Results Laboratory tests for hypercoagulability were positive for PT 20210 A variant. The patient's family tested negative for the PT variant. Conclusions Laboratory tests for coagulopathy, including the PT 20210 A variant, should be added to the examination of patients with central or BRVO, especially if most commo…
Retinal light sensitivity of the central visual field among 70- to 81-year-old men and women.
2009
Retinal light sensitivity of the central visual field (0-30 degrees), visual acuity, intraocular pressure and pupillary size were screened in 42 men and 42 women aged 70 to 81 years. The subjects were randomly selected from the population register. After excluding the diagnosed glaucoma cases, the men had better visual field light sensitivity values than the women. They also had lower intraocular pressure and a wider pupillary diameter than the women, whereas there were no differences in visual acuity between the sexes. When the effect of pupillary size was controlled the differences in visual field light sensitivity values between men and women became non-significant. Among these elderly p…
Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism
2017
Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…