Search results for "Optometry"

showing 10 items of 812 documents

Corneal Aberrations in Former Preterm Infants: Results From The Wiesbaden Prematurity Study

2017

Purpose To compare corneal aberrations in former preterm infants to that of full-term infants. Methods A prospective cross-sectional study was carried out measuring the corneal shape with Scheimpflug imaging in former preterm infants of gestational age (GA) ≤32 weeks and full-term infants with GA ≥37 weeks now being aged between 4 to 10 years. The main outcome measures were corneal aberrations including astigmatism (Zernike: Z2-2; Z22), coma (Z3-1; Z31), trefoil (Z3-3; Z33), spherical aberration (Z40) and root-mean square of higher-order aberrations (RMS HOA). Multivariable analysis was performed to assess independent associations of gestational age groups and of retinopathy of prematurity …

Malemedicine.medical_specialtyCorneal Wavefront AberrationScheimpflug principleGestational AgeAstigmatism03 medical and health sciences0302 clinical medicineCorneaOphthalmologymedicineHumansRetinopathy of PrematurityProspective StudiesChildProspective cohort studyComabusiness.industryInfant NewbornCase-control studyGestational ageRetinopathy of prematuritymedicine.diseaseeye diseasesCross-Sectional Studiesmedicine.anatomical_structureCase-Control StudiesChild PreschoolMultivariate Analysis030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessInfant Premature030217 neurology & neurosurgeryInvestigative Opthalmology & Visual Science
researchProduct

Prospective visual evaluation of apodized diffractive intraocular lenses

2006

To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…

Malemedicine.medical_specialtyDistance visual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologymedicineHumansContrast (vision)In patientProspective StudiesAgedmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesPatient SatisfactionQuality of LifeOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Prospective study of the Acri.LISA bifocal intraocular lens

2007

To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensCataractContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologyHumansMedicineContrast (vision)Prospective StudiesProspective cohort studyAgedmedia_commonLenses IntraocularVision BinocularPhacoemulsificationMonocularbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation

2007

Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityEmmetropiaIntraocular lensProsthesis DesignOphthalmoscopyTonometry OcularLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularClear lens extractionPhacoemulsificationmedicine.diagnostic_testbusiness.industryPhacoemulsificationPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOptometryFemalesense organsbusinessOphthalmology
researchProduct

Comparison of two artificial tear formulations for dry eye through high‐resolution optical coherence tomography

2011

Purpose:  The aim was to determine the efficacy of two artificial eye-drop formulations by analysing the lower tear film meniscus volume through a commercial high-resolution spectral-domain optical coherence tomographer. Methods:  Twenty dry eye patients (12 men, eight women, aged 57.5 ± 8.4 years) with refractive errors from -2.50 to +0.75 D (mean -1.34 ± 1.02 D) and cylinders lower than 1.00 D were examined. Tear meniscus volume was measured before, immediately after and 10, 30 and 60 minutes after instillation using the Copernicus high-resolution spectral-domain optical coherence tomographer (Optopol Tech SA, Zawiercie, Poland). Volume was calculated from the local area obtained from tom…

Malemedicine.medical_specialtyDrug Compoundingmedicine.medical_treatmentDry Eye SyndromesHigh resolutionMeniscus (anatomy)Young AdultOptical coherence tomographyReference ValuesOphthalmologymedicineHumansSurface Tensionmedicine.diagnostic_testbusiness.industryImage Enhancementeye diseasesSurgeryOphthalmologyArtificial tearsmedicine.anatomical_structureVolume (thermodynamics)TearsTearsDry Eye SyndromesFemalesense organsEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryClinical and Experimental Optometry
researchProduct

TFOS DEWS II Sex, Gender, and Hormones Report

2017

One of the most compelling features of dry eye disease (DED) is that it occurs more frequently in women than men. In fact, the female sex is a significant risk factor for the development of DED. This sex-related difference in DED prevalence is attributed in large part to the effects of sex steroids (e.g. androgens, estrogens), hypothalamic-pituitary hormones, glucocorticoids, insulin, insulin-like growth factor 1 and thyroid hormones, as well as to the sex chromosome complement, sex-specific autosomal factors and epigenetics (e.g. microRNAs). In addition to sex, gender also appears to be a risk factor for DED. “Gender” and “sex” are words that are often used interchangeably, but the…

Malemedicine.medical_specialtyDry eye workshopKeratoconjunctivitis SiccaDiseaseAffect (psychology)03 medical and health sciences0302 clinical medicineRisk FactorsService utilizationInternal medicineSex gendermedicineHumansSignificant riskDry eye diseaseRisk factorSex Characteristicsbusiness.industryESTRÓGENOSTFOSFemale sexGenderEstrogensHormoneHormonesDEWS II Dry eye disease Dry eye workshop Gender Hormones Sex TFOS OphthalmologyOphthalmologyEndocrinologyDEWS II030221 ophthalmology & optometryDry Eye SyndromesFemaleSexbusiness030217 neurology & neurosurgeryClinical psychologyHormone
researchProduct

Branch retinal vein occlusion associated with the 20210 G-to-A prothrombin variant.

2000

Purpose To describe a case of branch retinal vein occlusion (BRVO) in a patient who tested positive for the 20210 A allele of the prothrombin (PT) gene. Methods A 48-year-old man had visual loss in the right eye secondary to BRVO confirmed by ophthalmoscopy and fluorescein angiography. His medical history was not remarkable for common risk factors for retinal occlusive diseases. Results Laboratory tests for hypercoagulability were positive for PT 20210 A variant. The patient's family tested negative for the PT variant. Conclusions Laboratory tests for coagulopathy, including the PT 20210 A variant, should be added to the examination of patients with central or BRVO, especially if most commo…

Malemedicine.medical_specialtyEye diseaseVisual AcuityBlindnessOphthalmoscopy03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOphthalmologyRetinal Vein OcclusionCoagulopathyMedicineHumansPoint MutationFluorescein AngiographyClotting factormedicine.diagnostic_testbusiness.industryGenetic VariationRetinalGeneral MedicineMiddle Agedmedicine.diseaseFluorescein angiographyThrombosisSurgeryOphthalmologychemistry030221 ophthalmology & optometryBranch retinal vein occlusionProthrombinbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Retinal light sensitivity of the central visual field among 70- to 81-year-old men and women.

2009

Retinal light sensitivity of the central visual field (0-30 degrees), visual acuity, intraocular pressure and pupillary size were screened in 42 men and 42 women aged 70 to 81 years. The subjects were randomly selected from the population register. After excluding the diagnosed glaucoma cases, the men had better visual field light sensitivity values than the women. They also had lower intraocular pressure and a wider pupillary diameter than the women, whereas there were no differences in visual acuity between the sexes. When the effect of pupillary size was controlled the differences in visual field light sensitivity values between men and women became non-significant. Among these elderly p…

Malemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresLightVisual AcuityGlaucomaRetinachemistry.chemical_compoundRandom AllocationOphthalmologymedicineHumansCentral visual fieldIntraocular PressureAgedAged 80 and overLight sensitivitybusiness.industryRetinalPupilGeneral Medicinemedicine.diseaseeye diseasesVisual fieldOphthalmologychemistrySensory ThresholdsOptometryFemalemedicine.symptomVisual FieldsbusinessPopulation RegisterActa ophthalmologica
researchProduct

Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism

2017

Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…

Malemedicine.medical_specialtyKeratoconusCorneal Wavefront AberrationVisual acuityCorneal ectasiagenetic structuresContact LensesVisual AcuityAstigmatismKeratoconusCornea03 medical and health sciences0302 clinical medicineProsthesis FittingOphthalmologyCorneamedicineHumansHigh orderIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyEye Diseases HereditaryCorneoscleral contact lensGeneral MedicineMiddle Agedmedicine.diseaseCorneal topographyeye diseasesOphthalmologyHyperopiamedicine.anatomical_structureEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessSclera030217 neurology & neurosurgeryOptometry
researchProduct