Search results for "Optometry"

showing 10 items of 812 documents

Supplier behavior and its impact on customer satisfaction: A new characterization of negotiation behavior

2019

Abstract Many questions of customer/supplier negotiation dynamics remain unanswered. One reason behind this is that most existing models do not entirely reflect the complex relationship between negotiation behavior and the attained outcome of the negotiation process, analyzing the former from a purely dichotomous perspective. This study examines supplier negotiation behavior and how it impacts the outcome (satisfaction) from the customer´s perspective, thereby proposing a new characterization of negotiation behavior. Our analysis is based on a case study of 21 customer/supplier negotiations carried out by four leading supermarket chains in Costa Rica. Evidence supports our proposal that in …

MarketingProcess managementStrategy and Managementmedia_common.quotation_subjectPerceived satisfaction05 social sciencesPerspective (graphical)Outcome (game theory)03 medical and health sciencesNegotiation0302 clinical medicine0502 economics and business030221 ophthalmology & optometryCustomer satisfactionBusiness050203 business & managementmedia_commonJournal of Purchasing and Supply Management
researchProduct

In vitro power profiles of daily disposable contact lenses

2012

Abstract Purpose To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles. Methods The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5 mm to 5.5 mm in steps of 0.5 mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2 mm to 1.0 mm in steps of 0.2…

Materials scienceContact LensesAperturebusiness.industryOptical powerEquipment DesignGeneral Medicinelaw.inventionPower (physics)Equipment Failure AnalysisLens (optics)Contact lensOphthalmologyOpticslawDaily disposablesense organsBack vertex powerDisposable EquipmentbusinessDioptreOptometryContact Lens and Anterior Eye
researchProduct

True and Apparent Oxygen Permeabilities of Contact Lenses

1992

We studied the passage of oxygen through some commercially available contact lenses. Oxygen diffusion coefficients were determined by the time-lag method and a 201T Redher permeometer was used to measure the oxygen permeability and transmissibility by the polarographic method. The measurements were carried out at room temperature with 0.09% sodium chloride physiologic solution. The following types of lenses were tested: (1) 12 lenses of cellulose acetate butyrate (CAB) of a mean thickness of 0.194 mm (observed Dk approximately 6.3 barrers) (1 barrier is equivalent to 10(-11) cm3 of O2 (STP).cm2/cm3.s.mm Hg). (2) 13 lenses of a cross-linked polyhydroxyethyl methacrylate (2-HEMA), manufacture…

Materials scienceContact LensesDiffusionSodiumAnalytical chemistrychemistry.chemical_elementMineralogyOxygenPermeabilityOxygenContact lensOphthalmologyOxygen permeabilitychemistryPermeability (electromagnetism)Water contentChemical compositionPolarographyOptometryOptometry and Vision Science
researchProduct

Optical power distribution of refractive and aspheric multifocal contact lenses: Effect of pupil size

2015

Abstract Purpose To evaluate the power profile within the optic zone of different designs of multifocal contact lenses (CLs) and to analyze how the effect of pupil size could impact on their optical performance. Methods The optical power distribution within the optic zones of multifocal CLs was measured by the Nimo TR1504 (LAMBDA-X, Belgium). The multifocal CLs under study were the Acuvue Bifocal, the Acuvue Oasys for Presbyopia, the PureVision Multifocal and the PureVision 2 for Presbyopia. Each design was considered in all their available addition powers. All lenses had a nominal power of −3.0D. At the same time, three lenses of each model were considered and five consecutive readings of …

Materials scienceLightContact LensesPupil diameterIrisOptical powerlaw.inventionCLs upper limitsOpticslawmedicineHumansScattering Radiationbusiness.industryPupil sizeEquipment DesignPresbyopiaGeneral MedicinePresbyopiamedicine.diseaseRefractionEquipment Failure AnalysisLens (optics)RefractometryOphthalmologybusinessOptometryContact Lens and Anterior Eye
researchProduct

Creep–recovery and oscillatory rheology of flour-based systems

2023

The chapter reviews the application of creep-recovery and oscillatory rheological tests in flour based systems, including simple flour water systems, and more complex ones, such as bread, cookies and biscuits. A theoretical introduction about the fundaments and methods of linear viscoelastic rheology is presented, including general mathematical models and their application in flour based systems. A summary of experimental conditions to perform the rheological tests is covered. Functionality of flour based systems is extremely dependent on their viscoelastic properties. Processes like mixing, pumping, lamination, baking performance have been found to be strongly dependent on the system visco…

Materials scienceMathematical modelMixing (process engineering)04 agricultural and veterinary sciences040401 food scienceViscoelasticitylaw.inventionCondensed Matter::Soft Condensed Matter03 medical and health sciences0404 agricultural biotechnology0302 clinical medicineCreepRheologylawLaminationOscillatory rheology030221 ophthalmology & optometryComposite material
researchProduct

Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manu…

2007

PURPOSE: The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. METHODS: Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range…

Materials scienceSiliconesRefractive indexBiomedical EngineeringAnalytical chemistryBiocompatible Materials02 engineering and technologyBiomaterials03 medical and health sciences0302 clinical medicineRefractometerHumansBrix sucrose scaleBrix scaleCLR 12-70Water contentSoft contact lenseschemistry.chemical_classificationScience & TechnologyEquilibrium water contentWaterHydrogelsAtago N2EsucrosePolymerSilicone hydrogelconventional soft contact lensesContact Lenses Hydrophilic021001 nanoscience & nanotechnologyContact lensRefractometrychemistrySelf-healing hydrogelsSilicone hydrogel030221 ophthalmology & optometry0210 nano-technologyRefractometryRefractive indexJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy

2006

The purpose of this study was to analyze three commercial siloxane-hydrogel contact lens materials, lotrafilcon A, balafilcon A, and galyfilcon A, by cryogenic scanning electron microscopy (cryoSEM). The fully hydrated lenses were frozen in slush liquid nitrogen and qualitatively observed in a cryogenic scanning electron microscope. The superficial ultrastructure of the siloxane-hydrogels was observed at the areas where the lens fractured during sample cryogenic preparation. There are qualitative differences among the three examined materials in the complex polymer network structure existing between the outer layer and the underlying polymer. CryoSEM, although destructive, is a useful tool …

Materials scienceSiloxanesScanning electron microscopeSurface PropertiesBiomedical Engineering02 engineering and technologyContact lens materialsHydrogel Polyethylene Glycol Dimethacrylatelaw.inventionBiomaterials03 medical and health sciences0302 clinical medicineOpticssilicone-hydrogellawMicroscopyMaterials TestingHumansCryo-scanning electron microscopyComposite materialchemistry.chemical_classificationScience & Technologybusiness.industryCryoelectron MicroscopyCryoSEM microscopyPolymerLiquid nitrogenpolymer surface021001 nanoscience & nanotechnologyContact Lenses HydrophilicSiloxane-hydrogel contact lensescryoSEMLens (optics)Contact lenschemistry030221 ophthalmology & optometryUltrastructuremicroscopysiloxane-hydrogels0210 nano-technologybusiness
researchProduct

Microscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy

2006

In the present study, samples of lotrafilcon A, balafilcon A, and galyfilcon A contact lenses were observed by atomic force microscopy (AFM) in tapping mode at areas ranging from 0.25 to 400 m2. Mean roughness (Ra), root-mean-square roughness (Rms) and maximum roughness (Rmax) in nanometers were obtained for the three lens materials at different magnifications. The three contact lenses showed significantly different surface topography. However, roughness values were dependent of the surface area to be analyzed. For a 1 m2 area, statistics revealed a significantly more irregular surface of balafilcon A (Ra = 6.44 nm; Rms = 8.30 nm; Rmax = 96.82 nm) compared with lotrafilcon A (Ra = 2.40 nm; …

Materials scienceSiloxanesSurface PropertiesBiomedical EngineeringNanotechnology02 engineering and technologyMicroscopy Atomic ForceHydrogel Polyethylene Glycol DimethacrylateBiomaterialsAtomic force microscopy03 medical and health scienceschemistry.chemical_compoundSurface roughness0302 clinical medicineMaterials TestingSurface roughnessHumansScience & TechnologyAtomic force microscopyContact Lenses Hydrophilic021001 nanoscience & nanotechnologySiloxane-hydrogel contact lenses3. Good healthMicroscopic observationchemistrySiloxaneWettability030221 ophthalmology & optometry0210 nano-technologyJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

Optical quality comparison among different Boston contact lens materials.

2014

BACKGROUND The aim was to assess the optical quality of four Boston contact lens materials with an optical device based on Schlieren interferometry. METHODS The NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to measure higher-order aberrations and their corresponding root mean square values of four different rigid gas permeable contact lenses made from four different Boston materials: EO, ES, XO and XO2 . For each lens, 30 measurements were performed with two optical apertures: 3.0 mm and 6.0 mm. The modulation transfer function, point spread function, Strehl ratio and a simulation of the image provided by the lens were computed from the Zernike coefficients measured up to the fourth or…

Materials sciencebusiness.industryApertureContact LensesStrehl ratio02 engineering and technology021001 nanoscience & nanotechnologylaw.inventionRoot mean squareContact lensLens (optics)03 medical and health sciencesOphthalmologyInterferometry0302 clinical medicineOpticslawSchlierenOptical transfer function030221 ophthalmology & optometry0210 nano-technologybusinessOptometryClinicalexperimental optometry
researchProduct

Measuring the refractive state of an eye based on the intensity of the retinal reflex

2017

AbstractWhen examining the fundus of the eye with an ophthalmoscope, the intensity of the retinal reflex depends on the refractive state of the eye. In this study, application of this phenomenon for measuring the refractive state of the eye is demonstrated. First, a calibration curve relating the intensity of the retinal reflex and the refractive state was obtained using a model eye. Next, the intensity of the retinal reflex was measured while subjects were viewing a checker-board pattern, the distance of which was varied within the range from 0.17 to 1 m. Further, the relation between the refractive state and the optical power of the stimulus could be determined based on the measured light…

Materials sciencegenetic structuresbusiness.industryCalibration curve05 social sciencesOptical powerRetinaleye diseases050105 experimental psychologyAtomic and Molecular Physics and Optics03 medical and health scienceschemistry.chemical_compoundLight intensity0302 clinical medicineOpticschemistry030221 ophthalmology & optometryReflex0501 psychology and cognitive sciencessense organsbusinessAccommodationJournal of Modern Optics
researchProduct