Search results for "Optometry"

showing 10 items of 812 documents

Visual processing in patients with age-related macular degeneration performing a face detection test

2017

Purpose: People with age-related macular degeneration (AMD) have difficulties in familiar face recognition and facial expression discrimination. Our aim was to evaluate the visual processing of faces in AMD patients and whether this would be improved by anti-vascular endothelial growth factor therapy. This was a prospective interventional cohort study. Patients: Twelve patients with monocular wet AMD and 6 control subjects were recruited. Face detection processes were studied using cortical event-related potentials (ERPs). Patients received 3 bevacizumab intravitreal injections to the single affected eye. At baseline and 4–6 weeks after the last injection, clinical presentation and ERPs of …

medicine.medical_specialtyVisual acuityBevacizumabgenetic structuresfacial expressionsElectroencephalographybevacizumabfacial recognitionVisual processing03 medical and health sciences0302 clinical medicineOphthalmologymedicineilmeetEEGage-related eye diseasesFace detectionta315tunnistaminenOriginal ResearchFacial expressionMonocularmedicine.diagnostic_testbusiness.industryvisuaalisuuseye diseasesta3141Clinical OphthalmologyMacular degenerationRE1-994medicine.diseaseeye diseasesOphthalmologyvisualityN170silmätaudit030221 ophthalmology & optometrysense organsmedicine.symptomrecognitionbusiness030217 neurology & neurosurgerykasvontunnistus (tietotekniikka)medicine.drugface recognitionClinical Ophthalmology
researchProduct

Observational outcomes in proliferative diabetic retinopathy patients following treatment with ranibizumab, panretinal laser photocoagulation or comb…

2021

Purpose Ranibizumab monotherapy showed stronger effects on area of retinal neovascularization (NV) reduction while offering better visual acuity (VA) results than panretinal laser photocoagulation (PRP) monotherapy during the first 12 months of the PRIDE study. The second year of PRIDE was an observational, non-interventional follow-up, performed to evaluate long-term anatomical and functional outcomes in proliferative diabetic retinopathy (PDR) patients under real-life conditions, prior to the approval of ranibizumab for PDR. Methods Seventy-three PDR patients (28 from the ranibizumab group; 20 from the PRP group; 25 from the combination group) were included in the observational follow-up …

medicine.medical_specialtyVisual acuityCombination therapyVisual AcuityAngiogenesis InhibitorsLight CoagulationPanretinal laser photocoagulation03 medical and health sciencesRetinal neovascularization0302 clinical medicineOphthalmologyRanibizumabMedicineHumansDiabetic Retinopathybusiness.industryGeneral MedicineDiabetic retinopathymedicine.diseaseCombined Modality TherapyDiscontinuationOphthalmologyIntravitreal Injections030221 ophthalmology & optometryObservational studyRanibizumabmedicine.symptombusiness030217 neurology & neurosurgerymedicine.drugFollow-Up StudiesActa ophthalmologicaReferences
researchProduct

Visual acuity and contrast sensitivity screening with a new iPad application

2016

We present a new iPad application (app) for a fast assessment of Visual Acuity (VA) and Contrast Sensitivity (CS) whose reliability and agreement was evaluated versus a commercial screening device (Optec 6500). The measurement of VA was programmed in the app in accordance with the Amblyopia Treatment Study protocol. The CS was measured with sinusoidal gratings of four different spatial frequencies: 3, 6, 12 and 18 cpd at the same contrast values of the Functional Acuity Contrast Test (FACT) included in the Optec 6500. Forty-five healthy subjects with monocular corrected visual acuities better than 0.2 logMAR participated in the agreement study. Bland-Altman analyses were performed to assess…

medicine.medical_specialtyVisual acuityVisual acuitygenetic structuresComputer sciencemedia_common.quotation_subject01 natural sciences010104 statistics & probability03 medical and health sciences0302 clinical medicineOphthalmologymedicineContrast (vision)Computer visionContrast sensitivity0101 mathematicsElectrical and Electronic Engineeringmedia_commonbusiness.industryLimits of agreementHealthy subjectsFunctional acuity contrast testHuman-Computer InteractioniPadHardware and ArchitectureTreatment studyFISICA APLICADA030221 ophthalmology & optometryScreeningSpatial frequencyArtificial intelligencemedicine.symptombusinessSensitivity (electronics)
researchProduct

Automated macular choroidal thickness measurement by swept-source optical coherence tomography in pseudoxanthoma elasticum

2016

Introduction Pseudoxanthoma elasticum (PXE) typically involves elastic fibers in blood vessels and Bruch membrane. Our purpose was to analyze retinal and choroidal macular thickness in patients with angioid streaks due PXE compared with a control group. Methods Best-corrected visual acuity (BCVA), axial length (AL), and macular swept-source optical coherence tomography were obtained. Automated segmentations of the retina and the choroid were used to obtain the corresponding thickness values. An age, gender and AL matched control group was used to compare the thickness values. Results Twelve eyes of 6 patients were included. The mean BCVA was 0.68 ± 0.29 versus 1.0 in controls (p < 0.001). T…

medicine.medical_specialtyVisual acuitygenetic structures03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOptical coherence tomographyOphthalmologymedicineNeovascularizationRetinamedicine.diagnostic_testChoroidbusiness.industryRetinalPseudoxanthoma elasticummedicine.diseaseeye diseasesPXEAutomated segmentationOphthalmologyAngioid streaksChoroidal neovascularizationmedicine.anatomical_structurechemistry030221 ophthalmology & optometryOriginal Articlesense organsChoroidmedicine.symptombusiness030217 neurology & neurosurgeryInternational Journal of Retina and Vitreous
researchProduct

Interocular differences in visual quality due to ocular aberrations and scattering in a patient with post-traumatic anisocoria: A case report

2012

AbstractA 41-year-old patient with visual disturbances after an ocular trauma in right eye three years before was carefully analyzed and discussed. No corneal or intraocular sequelae were present. Only a significant anisocoria could be observed. Right eye (RE) achieved a best spectacle-corrected visual acuity (BSCVA) of 0.05 LogMAR with a refraction of +0.50 sphere and −1.25 cylinder. Left eye (LE) achieved a BSCVA of 0.0 LogMAR with a refraction of +0.75 sphere and −1.00 cylinder. In photopic conditions pupil diameter was 4.96mm for RE and 3.02mm for LE whereas in scotopic conditions, these values were 7.45mm and 6.71mm, respectively. More significant levels of higher-order corneal and ocu…

medicine.medical_specialtyVisual acuitygenetic structuresCase ReportPupilScatteringlcsh:OphthalmologyOphthalmologymedicinelcsh:QC350-467AberraciónScotopic visionPupilaAnisocoriabusiness.industryFunción de dispersión del puntoPupil sizePupilRefractionAnisocoriaPoint spread functioneye diseasesDispersiónlcsh:RE1-994Visual DisturbanceOptometrysense organsmedicine.symptombusinessAberrationlcsh:Optics. LightPhotopic visionOptometryJournal of Optometry
researchProduct

Impact of the pupil size – central optical zone diameter relationship on visual performance in aspheric multifocal contact lenses

2020

Abstract Purpose To determine the impact of different central optical zone diameters (COZDs), obtained from pupil size, on the visual performance of presbyopic subjects fitted with centre-distance simultaneous-image multifocal contact lenses (SIMCLs). Methods Thirty-two presbyopic volunteers, between 45–58 years of age, participated in this prospective, controlled, double-blind study. Subjects were fitted with 5 centre-distance SIMCLs of variable COZD, determined from the measurement of pupil size under photopic light conditions and corresponding to 60, 70, 80, 90 and 100 % of pupil diameter. Subjects visual performance was evaluated through the measurement of distance, intermediate and nea…

medicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedia_common.quotation_subjectVisual AcuityPupil diameterNear visual acuityCycles per degreeContrast SensitivityDouble-Blind MethodOphthalmologymedicineHumansContrast (vision)Prospective Studiesmedia_commonMathematicsPupil sizePupilGeneral MedicineMiddle Agedeye diseasesOphthalmologySpatial frequencymedicine.symptomOptometryPhotopic visionContact Lens and Anterior Eye
researchProduct

Effect of Varying Levels of Glare on Contrast Sensitivity Measurements of Young Healthy Individuals Under Photopic and Mesopic Vision

2018

Contrast sensitivity (CS), the ability to detect small spatial changes of luminance, is a fundamental aspect of vision. However, while visual acuity is commonly measured in eye clinics, CS is often not assessed. At issue is that tests of CS are not highly standardized in the field and that, in many cases, optotypes used are not sensitive enough to measure graduations of performance and visual abilities within the normal range. Here, in order to develop more sensitive measures of CS, we examined how CS is affected by different combinations of glare and ambient lighting in young healthy participants. We found that low levels of glare have a relatively small impact on vision under both photopi…

medicine.medical_specialtyVisual acuitygenetic structuresEcological validityMesopic visionmedia_common.quotation_subjectcontrast sensitivity functionlcsh:BF1-990AudiologyEyeLuminanceVisual processing03 medical and health sciences0302 clinical medicineglare effectClinical ResearchmedicineContrast (vision)PsychologyEye Disease and Disorders of VisionGeneral Psychologymedia_commonOriginal Researchvisual function measurementNeurosciencesGlare (vision)mesopic visioneye diseasesphotopic visionlcsh:Psychology030221 ophthalmology & optometryCognitive Sciencesmedicine.symptomPsychology030217 neurology & neurosurgeryPhotopic visionFrontiers in Psychology
researchProduct

Reading ability with 3 multifocal intraocular lens models.

2006

Purpose To prospectively evaluate reading performance with of 3 types of multifocal intraocular lenses (IOLs) under different lighting conditions based on reading acuity and reading speed tests. Setting Augenklinik, Bad Hersfeld, Germany. Methods This randomized study comprised 60 cataract patients (120 eyes) randomly assigned to receive an SA40N IOL (AMO) (Group 1, 20 patients), Tecnis ZM001 IOL (AMO) (Group 2, 20 patients), or AcrySof ReSTOR SA60D3 IOL (Alcon) (Group 3, 20 patients). Pupil size and reading ability at near (visual acuity, reading speed) without correction, with best distance correction, and with best near correction were assessed 6 weeks postoperatively under low-light con…

medicine.medical_specialtyVisual acuitygenetic structuresLightPseudophakiamedicine.medical_treatmentmedia_common.quotation_subjectEye diseaseVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularOphthalmologyReading (process)medicineHumansProspective Studiesmedia_commonLenses IntraocularPhacoemulsificationbusiness.industrySignificant differencePupil sizePupilMultifocal intraocular lensMiddle Agedmedicine.diseaseDistance correctioneye diseasesSensory SystemsOphthalmologyReadingOptometrySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

The Impact on Vision of Aspheric to Spherical Monofocal Intraocular Lenses in Cataract Surgery

2013

Purpose To provide a summary of the impact on vision of an aspheric intraocular lens (IOL) compared with a spherical IOL in cataract surgery. Design Systematic review with meta-analysis. Participants Patients from published randomized controlled trials (RCTs) of cataract surgery with aspheric compared with spherical monofocal IOL implantation. Methods We systematically searched the peer-reviewed literature in MEDLINE, EMBASE, Web of Science, BIOSIS, and the Cochrane Library according to the Cochrane Collaboration method to identify relevant RCTs. The inclusion criteria were RCTs on cataract surgery comparing the use of aspheric versus spherical IOL implantation that assessed visual acuity, …

medicine.medical_specialtyVisual acuitygenetic structuresbusiness.industryMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentIntraocular lensCochrane LibraryCataract surgeryeye diseasesOphthalmologyMeta-analysisOphthalmologyContrast (vision)MedicineOptometrysense organsmedicine.symptombusinessmedia_commonPhotopic visionOphthalmology
researchProduct

Efficacy and safety of ranibizumab with or without panretinal laser photocoagulation versus laser photocoagulation alone in proliferative diabetic re…

2019

Purpose Panretinal photocoagulation (PRP) is the current standard of care in proliferative diabetic retinopathy (PDR). However, treatment with anti-vascular endothelial growth factor agents might offer better patient outcomes with fewer side-effects. The PRIDE study aimed to assess the efficacy and safety of ranibizumab with or without PRP compared with PRP alone in patients with PDR. Methods A total of 106 PDR patients without diabetic macular oedema were randomized to receive ranibizumab 0.5 mg monotherapy (n = 35), PRP (n = 35) or combined ranibizumab 0.5 mg/PRP (n = 36). The primary objective of this 12-month, multicentre, phase II study was to investigate the change in area of retinal …

medicine.medical_specialtyVisual acuitygenetic structuresbusiness.industrySignificant differencePhases of clinical researchGeneral MedicineDiabetic retinopathyPanretinal laser photocoagulationmedicine.diseaseAlternative treatment03 medical and health sciencesOphthalmologyRetinal neovascularization0302 clinical medicineOphthalmology030221 ophthalmology & optometrymedicineRanibizumabmedicine.symptombusiness030217 neurology & neurosurgerymedicine.drugActa Ophthalmologica
researchProduct