Orbscan Pachymetry: Differences between observers when carrying out measurements of the corneal thickness

2005

espanolObjetivo: Estudiar el espesor corneal y la variabilidad entre observadores de las mediciones del espesor corneal empleando paquimetria Orbscan. Metodos: Analizamos el espesor corneal central y paracentral de 30 sujetos (n=30) cuya edad oscilaba entre 19 y 38 anos (media 27,27 D.E. 5,25) con el Sistema Topografico Orbscan II (Orbscan, Inc., Salt Lake City, UT, USA). La media de cinco mediciones consecutivas del espesor corneal fue obtenida por dos diferentes observadores. Los resultados obtenidos por los dos observadores se compararon. Resultados: No se encontraron diferencias significativas entre los valores medios del espesor corneal de los observadores en la cornea central (p=0,749…

Physicsmedicine.medical_specialtycorneal thicknessSalt lakeCórneaCorneaOphthalmologymedicine.anatomical_structureOrbscanCorneaOphthalmologymedicinepachymetryOrbscan iiCartographypaquimetríaespesor corneal
researchProduct

Evaluation of the anterior chamber angle in keratoconus and normal subjects.

2015

To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…

AdultMaleKeratoconusmedicine.medical_specialtyKeratoconusSensitivity and SpecificityAnterior chamber angleAnterior Eye SegmentReference ValuesOphthalmologymedicineHumansOrbscan iiSlit Lampbusiness.industrySignificant differenceCorneal TopographyReproducibility of ResultsGeneral Medicinemedicine.diseaseControl subjectsOphthalmologyOptometryFemalebusinessTomography Optical CoherenceOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review

2016

We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…

White to whitemedicine.medical_specialtybusiness.industryReviewClinical Practice03 medical and health sciencesOphthalmologyAlcon LaboratoriesAnterior chamber eye0302 clinical medicineOphthalmology030221 ophthalmology & optometryMedicineOptometryOrbscan iiPentacam hrbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology