Search results for "Organs"
showing 10 items of 2730 documents
Iris-fixated toric phakic intraocular lens: Three-year follow-up
2006
Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…
Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometry
2007
Purpose: To compare central and peripheral intraocular pressure (IOP) readings obtained with rebound tonometry.Methods: Intraocular pressure was measured on the right eye of 153 patients (65 males, 88 females), aged from 21 to 85 years (mean +/- S.D., 55.5 +/- 15.2 years) with the ICare rebound tonometer at centre, and 2 mm from the limbus (in the nasal and temporal regions along the 0-180O corneal meridian).Results: Intraocular pressure values obtained with the ICare were 14.9 +/- 2.8; 14.1 +/- 2.5 and 14.5 +/- 2.7 mmHg at centre, nasal and temporal corneal locations, respectively. On average, nasal and temporal IOP readings were 0.75 and 0.37 mmHg lower than the central reading (p 0.05, r…
Neuromuscular Differences Between Endurance-Trained, Power-Trained, and Sedentary Subjects
2003
This study tested the hypothesis that neuromuscular characteristics of plantar flexor (PF) and knee extensor (KE) muscles explain differences of both performance in vertical jump and maximal voluntary isometric contraction (MVC) between endurance-trained (END, n = 9), power-trained (POW, n = 8), and sedentary subjects (SED, n = 8). Evoked twitch characteristics of PF and KE were measured. MVC, maximal voluntary activation (%VA) of KE, and performance in vertical jump were also measured. POW have higher maximal rate of twitch force development (MRFD) than SED and END for both PF (p < 0.05) and KE (p < 0.01); %VA and MVC were higher for POW and END than SED (p < 0.01). Higher performances wer…
Cutaneous, genital and oral lichen planus: a descriptive study of 274 patients
2018
Background Lichen planus (LP) is a chronic autoimmune disease that affects the oral mucosa as well as the skin, genital mucosa and other sites. Objective: to evaluate the correlation between oral, genital and cutaneous lichen planus, in a sample of LP patients. Material and Methods This descriptive study reviewed 274 clinical histories of patients, who all presented histological confirmation of lichen planus verified by a pathologist, attending research centers in Barcelona. Results A total of 40 LP patients (14.59%) presented genital lesions. Of 131 patients with cutaneous LP (47.8%), the most commonly affected zones were the body’s flexor surfaces, representing 60.1% of cases. 24% of pati…
A 12-month Prospective Study of Tear Osmolarity in Contact Lens Wearers Refitted with Daily Disposable Soft Contact Lenses
2020
SIGNIFICANCE Tear osmolarity has been reported as one of the best diagnostic tests for dry eye disease and its management. Contact lens wear is thought to influence tear homeostasis. Understanding how regular wear of contact lenses and their type affect tear osmolarity is important. PURPOSE The purpose of this study was to assess changes in tear osmolarity and ocular symptoms over a period of 12 months following refitting contact lens wearers with daily disposable contact lenses. METHODS Fifty subjects aged (mean ± SD) 26 ± 4 years were refitted with either silicone-hydrogel (delefilcon A, SiHy, n = 34) or hydrogel (omafilcon A, Hy, n = 16) daily disposable soft contact lenses. Study includ…
Assessment of corneal thickness and tear meniscus during contact-lens wear
2014
To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…
Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.
2008
To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…
The location by early auditory evoked potentials (EAEP) of acoustic nerve and brainstem demyelination in multiple sclerosis (MS).
1980
Tone pips of suprathreshold intensities elicit an acoustic nerve response (I) and six low amplitude brainstem potentials (II-VII) during the initial 10 ms. Seven waves were studied in 40 control subjects and 5 waves (I-V) in 47 patients with MS. The results suggest involvement of the auditory pathway of 24 of 27 patients in the clinically "definite", of 5 of 9 cases in the "probable" and in none of 5 patients in the "possible" MS groups. EAEPs were normal in 6 cases with a spinal form with one exception where changes of potential were indicative of a midbrain lesion. Dysfunction within the acoustic pathway was observed at the level of the acoustic nerve and in the medulla oblongata, pons an…
Meibomian glands structure in daily disposable soft contact lens wearers: a one‐year follow‐up study
2020
Purpose To assess the impact of daily disposable soft contact lenses on meibomian gland morphology over a period of 12 months. Methods Forty-one subjects (33 experienced and 8 neophytes) were fitted with either silicone-hydrogel or hydrogel daily contact lenses. The study protocol included four visits: baseline, day-2 for contact lens fit and follow-up measurements, as well as after 6 and 12 months of lens wear. Non-contact infrared meibography images were acquired with Keratograph 5M topographer (www.oculus.de) and analysed with an automated method, which objectively estimates the area of gland atrophy, gland length and width, number of glands and gland irregularity. Protocol at follow-up …
Ocular surface assessment in soft contact lens wearers; the contribution of tear osmolarity among other tests.
2014
: Purpose: To determine whether tear osmolarity contributes to the assessment of the ocular surface in soft contact lens (CL) wearers. Methods: Prospective, case–control series in 44 CL wearers (28 tolerant and 16 intolerant) and 34 healthy subjects. Every patient underwent a thorough ophthalmic examination with a tear osmolarity test (TearLab System), conjunctival impression cytology and meibomian lipid sampling. Symptoms, break-up time (BUT), tear osmolarity, conjunctival expression of HLA-DR and meibomian fatty acid composition were evaluated. Results: Tear osmolarity did not differ between controls and CL wearers (p = 0.23). Flow cytometry results expressed in antibody-binding capaci…