Search results for "Orthodontics."
showing 10 items of 920 documents
Stress distribution in fixed mandibular prostheses fabricated by CAD/CAM and conventional techniques: Photoelastic and strain gauge analyses
2019
Made available in DSpace on 2020-12-12T00:55:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-09-01 The aim of this study was to evaluate the distribution of stress in complete fixed mandibular prostheses with infrastructures (IE) fabricated with different materials and techniques, under compressive force. A model of an edentulous mandible, which received five 4x11 mm external hexagon implants between the mental foramens, was fabricated. The groups were divided into: Group I - IE in nickel-chromium with an acrylic resin occlusal coating; Group II - IE in nickel-chromium with a ceramic occlusal coating; Group III - IE milled in zirconia with a ceramic coating. For the photoelastic m…
Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones
2018
Background The purpose of this study was to evaluate the accuracy of fitting of an implant supported screw-retained bar made on definitive casts produced by 4 different dental stone products. Material and Methods The dental stones tested were QuickRock (Protechno), FujiRock (GC), Jade Stone (Whip Mix) and Moldasynt (Heraeus). Three external hexagon implants were placed in a polyoxymethylene block. Definitive impressions were made using monophase high viscosity polyvinylsiloxane in combination with custom trays. Then, definitive models from the different types of dental stones were fabricated. Three castable cylinders with a machined non-enganging base were cast and connected with a very sma…
Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review
2017
Background To carry out a systematic literature review of the causes of preload loss of the abutment screws, of internal and external connection implants, tightened to different torque values and subjected to cyclic loading. Material and methods A systematic search was conducted in PubMed, EMBASE, and Cochrane Library databases with reference to in vitro studies in which internal and external connection implants were subjected to cyclic loads to determine the degree of loosening of the abutment screws after loading. Results The reviewed studies tested distinct implant connections (mostly externally hexed, and morse taper) subjected to diverse cycles (from 16667 to 1 million), with loads ran…
Analysis of stress distribution in ceramic and titanium implants in alveolar sockets of the anterior region of the maxilla
2019
Background In the routine of dentistry, knowing the biomechanical properties of implant systems and their inherent stress distribution under force loading is an essential step to predict structural damage and biological responses. This study aimed to investigate stress distribution in zirconia and titanium implants and their biomechanical response in alveolar sockets of the anterior region of the maxilla through tridimensional finite element analysis. Material and Methods From computed tomography scans of a reference patient, three models of the maxillary dental arch were designed with Rhinoceros 5.0 software (McNeel Europe™, Barcelona, Spain). In each model, a dental implant replaced the m…
In vitro investigation of the impact of remaining tooth structure on the tensile failure loads of overdenture copings
2019
Background The purpose of this in vitro study was to evaluate the impact of the remaining tooth structure on the retention of overdenture cast metal copings. Material and Methods A freshly extracted intact mandibular human canine (length 25 mm) was selected and endodontically treated. An incisal reduction of 4 mm with no ferrule preparation was performed and a post space of 12 mm was created. By using polyvinyl siloxane duplication material and autopolymerizing polymethylmethacrylate resin, ten resin teeth analogs (control group) were obtained. A second set of ten resin teeth analogs (group 1) was created by preparing on the original natural tooth a 360o ferrule design of 1 mm in height and…
Conical connection adjustment in prosthetic abutments obtained by different techniques
2019
Background The goal of this study is to compare the misfit (>150µm) generated once the restoration, made by different techniques, is retained to a single conical implant. Material and methods 15 internal connection implants (MIS C1 4'20x10mm) are embedded each one perpendicularly to an horizontal surface of the 1x1x2cm poliuretan resin model. The 15 samples obtained are divided in 5 groups depending on the framework process (n=3): 1/casting, 2/overcasting, 3/Ti-base, 4/milling and 5/laser sintering. The cobalt-chromium alloy frameworks are screw-retained to their respective implants to a 30-Ncm torque. Once it is retained the framework to the implant, the next step is to section the sample …
Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially ed…
2018
Background Various factors like implant angulation, type of impression material and tray type affects the implant impression accuracy. To date limited in-vitro studies were carried out on the implant impression accuracy of unilateral partially edentulous arches. The aim of this research was to evaluate the effects of 0o, 15o and 25o implant angulations on impression accuracy in simulated master casts of unilateral partially edentulous situation using different impression materials and tray selections. Material and Methods 30 replicas (N = 30) of a resin matrix (control) containing four implant analogues placed unilaterally from the midline till the region of second molar at an angulation of…
Are different generations of CAD/CAM milling machines capable to produce restorations with similar quality?
2016
Background: Different CAD/CAM machinesâ generation may impact the restoration overall quality. The present study evaluated the marginal fit of CAD/CAM restorations manufactured with different generations of CEREC milling unit systems. Material and Methods: Sixteen typodont teeth were divided into two groups (n=8) according to the machineâ s generation assigned. These are control group (G1): Cerec AC with Bluecam/Cerec 3 milling unit and (G2): Cerec AC with Bluecam/MC XL Premium Package milling unit. Scanning of the preparation were performed and crowns were milled using the Vita Mark II blocks. Blocks were cemented using epoxy glue on the pulpal floor only and finger pressure applied for 1 …
A new technique to determine vertical dimension of occlusion from anthropometric measurement of interpupillary distance
2014
Background: A number of techniques are being practiced for the evaluation of VDO, but none of them is scientifically more accurate than other. Each method advocated has its own limitations. Objectives: The purpose of this study was to find correlation between vertical dimension of occlusion (VDO) and interpupillary distance (IPD). Material and Methods: A cross-sectional study was conducted on 400 dentate subjects comprising of 200 males and 200 females. Anthropometric measurement of VDO was recorded clinically using modified digital vernier caliper. Also, a standardized digital photograph of face was generated from the frontal aspect using a digital camera for the measurement of IPD in mill…
Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant retain…
2019
Background This study was aimed to evaluate the influence of inter-implant distance on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures. Material and methods Forty Completely edentulous participants aged between 50 - 70 years were enrolled in this study. Each patient received 2-implants by 2-stage submerged surgical protocol. Participants categorized into 4-groups. Group I: 19 mm inter-implant distance with Locator retained overdentures; Group II: 19 mm inter-implant distance with OT Equator retained overdentures; Group III: 25 mm inter-implant distance with Locator retained overdentures; Group IV: 25 mm inter-implant distance with OT…