6533b7d1fe1ef96bd125c26f
RESEARCH PRODUCT
In vitro investigation of the impact of remaining tooth structure on the tensile failure loads of overdenture copings
Argirios PissiotisSavvas N. KamalakidisKonstantinos MichalakisAnna Fotiousubject
OrthodonticsProsthetic DentistryMetal copingMaterials scienceResearchGlass ionomer cementPolymethylmethacrylate resinFerrule030206 dentistry:CIENCIAS MÉDICAS [UNESCO]03 medical and health sciencesPolyvinyl siloxane0302 clinical medicinestomatognathic systemUNESCO::CIENCIAS MÉDICASUltimate tensile strengthIn vitro study030212 general & internal medicineNatural toothGeneral Dentistrydescription
Background The purpose of this in vitro study was to evaluate the impact of the remaining tooth structure on the retention of overdenture cast metal copings. Material and Methods A freshly extracted intact mandibular human canine (length 25 mm) was selected and endodontically treated. An incisal reduction of 4 mm with no ferrule preparation was performed and a post space of 12 mm was created. By using polyvinyl siloxane duplication material and autopolymerizing polymethylmethacrylate resin, ten resin teeth analogs (control group) were obtained. A second set of ten resin teeth analogs (group 1) was created by preparing on the original natural tooth a 360o ferrule design of 1 mm in height and by using the same procedural technique. The canine was further reduced by an additional 1 mm, resulting in a ferrule of 2 mm in height, measured from the initial incisal reduction, thus a third set of ten resin teeth analogs (group 2) was created. For every tooth analog in all groups a dome-shaped metal coping was cast and luted with a glass ionomer cement. All specimens were subjected to tensile load testing until decementation occurred. Results The specimens in the control group exhibited a mean failure load of 87.21 ± 18.26 N, while the 1 mm ferrule group recorded a higher mean failure load of 125.43 ± 8.79 N and the 2 mm ferrule group recorded the highest mean failure load of 146.12 ± 23.38 N. One-way ANOVA revealed significant differences (F= 28.04, p<0.001) in the tensile failure loads between all of the groups being tested. Conclusions The metal copings with a 2 mm ferrule design exhibited the highest retention values, followed by the 1 mm ferrule and the no ferrule design, with the differences among them being statistically significant. Key words:Ferrule effect, In vitro study, Metal copings, Overdenture, Tensile stress.
| year | journal | country | edition | language |
|---|---|---|---|---|
| 2019-11-01 | Journal of Clinical and Experimental Dentistry |