Search results for "Orthopedic Surgery"
showing 10 items of 371 documents
Heart failure risk reduction : is fit and overweight or obese better than unfit and normal weight?
2019
This article refers to ‘Cardiorespiratory fitness, body mass index and heart failure incidence’ by P. Kokkinos et al., published in this issue on pages 436–444.
Managing Peripheral Artery Disease in Diabetic Patients: A Questionnaire Survey from Vascular Centers of the Mediterranean Federation for the Advanci…
2020
Background The Mediterranean Federation for the Advancing of Vascular Surgery (MeFAVS) was founded on October 1, 2018, to enhance cooperation among vascular professionals within Mediterranean countries. Due to its prominent social and economic impact on national health systems, diabetic arteriopathy has been selected as the very first topic to be investigated by the federation. Methods MeFAVS members were asked to reply to a questionnaire on the management of diabetic ischemic foot. Results were collected and analyzed statistically. The questionnaire consisted of 15 multiple choice answers regarding diabetic foot (DF) diagnosis and treatment. The questionnaire was submitted to 21 centers on…
The assessment of skeletal status in young patients with Turner syndrome by 2 densitometric techniques: Phalangeal quantitative ultrasound and dual e…
2018
Background. Studies using dual energy X-ray absorptiometry (DXA) demonstrate a reduction in bone mineral density (BMD) in children and adolescents with Turner syndrome (TS). However, these studies do not take into account changes in bone size, which influence BMD in the case of short-statured patients. Phalangeal quantitative ultrasound (phQUS) measurements have shown an ability to reveal changes due to skeletal growth, aging, and bone and mineral disorders. There is limited data on bone mineral status in girls with TS assessed by 2 different techniques, i.e., DXA and phQUS. Objectives. The aim of this study was to investigate the potential negative impact of TS on bone status and to assess…
The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.
2003
To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…
Surgery for fracture of the calcaneus. 5 (2-8) year follow-up of 20 cases.
1993
20 displaced intraarticular fractures of the calcaneus were treated by open reduction and internal fixation. Results were evaluated according to a standardized protocol. With an average follow-up of 5 (2-8) years, results were excellent or good in 15 cases and fair or poor in 5 cases. An accurate radiographic study and CT scanning are essential for understanding these fractures. We feel that restoring calcaneal shape as anatomic as possible, getting an appropriate reduction of the posterior joint surface by a surgical procedure with early mobilization, and delayed weight bearing would be a good option in treatment of these fractures.
Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.
2010
In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p < 0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p < 0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantl…
Cementless total hip replacement with subtrochanteric femoral shortening for severe developmental dysplasia of the hip.
2003
Total joint replacement in patients suffering from developmental dysplasia of the hip poses specific technical difficulties due to insufficient bone stock at the site of the original and secondary acetabulum and a narrow, cranially displaced proximal femur. Twelve hips with severe congenital dislocation (4 Crowe type II, 5 type III, 3 type IV) were treated with cementless, porous structured total hip replacement. The cup was implanted at the anatomic height, a femoral segment was resected below the minor trochanter to reduce the femoral component in all cases. One femoral component was exchanged for a longer stem after 2 months due to insufficient fit and fill. After a mean follow-up of 5.1…
A ten-year follow-up of the Reflection cementless acetabular component.
2008
We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…
Repair of osteochondral defects in articular weightbearing areas in the rabbit's knee. The use of autologous osteochondral and meniscal grafts.
1987
Repair of osteochondral defects in articular weightbearing areas presents its own particular problems because of the low potential of hyaline cartilage for regeneration. Our first group of experiments on the knee of the rabbit confirms that the new regenerated cartilage comes from bone marrow which degenerates before developing into true hyaline cartilage. The second group of experiments shows that autologous grafts from the non-weightbearing articular area suitable for the repair of defects in weightbearing areas. In an third group, autologous meniscal fibrocartilage was used as a graft for the repair of osteochondral defects.
Le Fratture di Rotula
2015
Patellar fractures are relatively uncommon, accounting for approximately 1% of all fractures. Non-operative treatment represents the best choice for undisplaced patellar fractures. However, surgery becomes necessary when fractures are displaced by more than 2 mm, and may include open reduction and internal fixation. Accurate reduction and rigid fixation are required in order to allow early knee mobilization and to obtain a better clinical outcome. Several techniques have been described for patellar fracture fixation, such as tension band wiring, interfragmentary screw fixation, and the combination of screw fixation and cerclage. In this article up-to-date diagnosis, classification and treat…