Search results for "Osseointegration"

showing 10 items of 130 documents

Measurement of dental implant stability by resonance frequency analysis : a review of the literature

2008

Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion) and secondary stability (bone formation and remodelling at implant-bone interface). The aim of this study was to review the literature on Resonance Frequency Analysis (RFA) as a method for measuring dental implant stability. An online search of various databases was conducted on experimental and clinical research published betw…

Secondary StabilityDental Implantsbusiness.industrymedicine.medical_treatmentDentistry:CIENCIAS MÉDICAS [UNESCO]OsseointegrationResonance frequency analysisOtorhinolaryngologyMechanical stabilityOsseointegrationUNESCO::CIENCIAS MÉDICASmedicineHumansSurgeryBone formationImplantGood outcomebusinessDental implantGeneral Dentistry
researchProduct

Biomechanics and Occlusion in Immediate Loading

2019

In this chapter, biomechanical concepts as tension, types of forces, and static and dynamic loads in oral implantology are explained. Also, biomechanical factors as type of bone, implant design, switching platform, connection type, crown-implant ratio, and passive fit are exposed. So, it is important to know keys for biomechanical control and occlusal pattern. The lowering of tensions is one of our aims when planning cases for immediate loading, since we know the complications they can cause. It is therefore necessary to reduce the incident forces or increase the surface upon which they fall. Increasing the number of implants is the most effective method for improving surface area and reduc…

Stress (mechanics)Orthodonticsbusiness.industryTension (physics)medicine.medical_treatmentOcclusionBiomechanicsFracture (geology)medicineImplantbusinessProsthesisOsseointegration
researchProduct

Effects of Ultraviolet Photoactivation on Osseointegration of Commercial Pure Titanium Dental Implant After 8 Weeks in a Rabbit Model

2020

This study investigated whether a 6-Watt ultraviolet C-lamp was capable of producing photofunctionalization on commercial implants during a medium observation term of 8 weeks. A total of 20 implants were inserted in 5 New Zealand rabbits, with each animal receiving 2 implants per tibia (one photofunctionalized and one untreated), according to a previously established randomization sequence. All implants were inserted by a single surgeon following the manufacturer's instructions. Histological analysis was performed by an evaluator who was blinded to the treatment condition. After 8 weeks of healing, the 2 groups showed no statistically significant differences in terms of bone-to-implant cont…

Surface Propertiesmedicine.medical_treatmentchemistry.chemical_elementDentistry02 engineering and technologyIrradiation timeOsseointegration03 medical and health sciences0302 clinical medicineOsseointegrationAnimalsMedicineTibiaDental implantDental ImplantsTitaniumTibiabusiness.industry030206 dentistry021001 nanoscience & nanotechnologySingle surgeonchemistryWettabilityRabbit modelRabbitsOral Surgery0210 nano-technologybusinessTitaniumJournal of Oral Implantology
researchProduct

Barbed Dental Ti6Al4V Alloy Screw : Design and Bench Testing

2023

Background context. Dental implants are designed to replace a missing tooth. Implant stability is vital to achieving osseointegration and successful implantation. Although there are many implants available on the market, there is room for improvement. Purpose. We describe a new dental implant with improved primary stability features. Study design. Lab bench test studies. Methods. We evaluated the new implant using static and flexion–compression fatigue tests with compression loads, 35 Ncm tightening torque, displacement control, 0.01 mm/s actuator movement speed, and 9–10 Hz load application frequency, obtaining a cyclic load diagram. We applied variable cyclic loadings of prede…

bone–implant interactions; osseointegration; titanium implants; porous implants; 3D printingGeneral Materials ScienceCirurgia Aparells i instruments
researchProduct

Influence of nicotine on machined- and anodized-surface implants. Histometric analysis

2017

Background The nicotine may generate a influence on bone repair and longevity of dental implants. This fact makes studies to improve the surface of the implants are constantly conducted. This study aimed to evaluate the influence of subcutaneous nicotine injection in the osseointegration process on different implant surfaces, through histomorphometric analysis. Material and Methods Therefore, twenty-two male rabbits were randomly distributed into two groups according to the subcutaneous injections: (1) nicotine, 3 mg/day/kg and (2) 0.9% NaCI, 3 mL/day/kg, three times a day. Subgroups were then designated - machined and anodized dental implants were installed in the right and left tibia bone…

business.industryResearchLow doseSignificant differenceLeft tibiaDentistry030206 dentistryBone healing030204 cardiovascular system & hematology:CIENCIAS MÉDICAS [UNESCO]OsseointegrationNicotine03 medical and health sciences0302 clinical medicineUNESCO::CIENCIAS MÉDICASMedicineStatistical analysisImplantOral SurgerybusinessGeneral Dentistrymedicine.drug
researchProduct

Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants

2014

Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…

business.industrymedicine.medical_treatmentArea under the curveDentistryAnatomyImplant stability quotientOsseointegrationResonance frequency analysisMaxillaImmediate loadingmedicineImplantOral SurgeryDenturesbusinessGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Bone Healing with or without Platelet-Rich Plasma around Four Different Dental Implant Surfaces in Beagle Dogs

2013

Purpose Surface development is one of the major aims in dental implant engineering. Additive application of substances could possibly improve the new bone formation around dental implants. The present study evaluated the bone reaction on four different implant surfaces with or without platelet-rich plasma (PRP). Materials and Methods Four self-tapping titanium screw implants (Branemark MK III [Nobel Biocare, Goteborg, Sweden], Osseotite [3i, Miami, FL, USA], Xive [Densply Friadent, Mannheim, Germany], and Compress [IGfZ eG, Diez, Germany]) with different surfaces were inserted in each hemimandible of 12 female beagle dogs; the implant positions and the application of PRP were randomized. Af…

business.industrymedicine.medical_treatmentDentistryBone healingBeagleOsseointegrationBone remodelingPlatelet-rich plasmaMedicineImplantOral SurgerybusinessBone regenerationDental implantGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Radiological assessment of peri-implant bone loss: a 12-month retrospective study

2011

Introduction: Following dental implant loading, marginal bone loss after one year must be evaluated to check correct maintenance of the bone levels. Objectives: To assess implant treatment success and quantify marginal bone loss 6 and 12 months after loading. Material and method: Sixty-one MIS® implants with a 1.8 mm machined neck were placed in 26 patients. Implant success was based on the criteria of Buser. Radiological controls were made 6 and 12 months after loading, measuring bone loss mesial and distal. Results: Twenty-two patients with 56 implants were included: 32 in the maxilla and 24 in the mandible. Two implants failed in two patients during the osseointegration phase (both in th…

business.industrymedicine.medical_treatmentMandibleDentistryRetrospective cohort studyOdontologíaPeri implant bone:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludOsseointegrationMaxillaRadiological weaponUNESCO::CIENCIAS MÉDICASmedicineImplantDental implantbusinessGeneral Dentistry
researchProduct

Stability and marginal bone loss in implants placed using piezoelectric osteotomy versus conventional drilling: systematic review and meta-analysis.

2021

Background The main objective of this systematic review was to compare primary and secondary implant stability between placement with piezoelectric osteotomy and conventional drilling, comparing marginal bone losses as a secondary objective. Material and Methods An electronic search was conducted using PubMed (MEDLINE), Scopus, and Cochrane Library (Wiley) databases, besides a manual search. Results A total of 153 articles were retrieved, 39 from Pubmed, 44 from Scopus, and 70 from the Cochrane Library. After removing duplicates, 112 articles (1 from the manual search) were screened, and 9 were finally selected for qualitative and statistical analyses. Conclusions Piezoelectric surgery is a…

caveolin-1medicine.medical_treatmentameloblastic carcinomareal-time polymerase chain reactioneducationMEDLINEDentistryReviewImplant stabilityCochrane LibraryOsteotomyOsseointegrationameloblastomaOsseointegrationMedicineHumansPiezosurgeryDental implantGeneral DentistryImplant site preparationUNESCO:CIENCIAS MÉDICASPiezoelectric surgeryDental Implantsbusiness.industryMarginal bone lossDental implantsDental Implantation EndosseousImplant stability quotientOsteotomyOtorhinolaryngologyPiezoelectric surgeryimmunohistochemistrySurgeryImplantbusinessImplantologyConventional drillMedicina oral, patologia oral y cirugia bucal
researchProduct

Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, osseodensification: an in vitro study

2020

Background Primary stability is an important key determinant of implant osseointegration. We investigated approaches to improve primary implant stability using a new drilling technique termed osseodensification (OD), which was compared with the conventional under-drilling (UD) method utilized for low-density bones. Material and Methods We placed 55 conical internal connection implants in each group, in 30 low-density sections of pig tibia. The implants were placed using twist drill bits in both groups; groups Under Drilling (UD) and Osseodensification (OD) included bone sections subjected to conventional UD and OD drilling, respectively. Before placing the implants, we randomized the bone s…

computer-assisted diagnosisMaterials scienceSwinecomputer-assisted image processingOsseointegrationDental Prosthesis Retentionradicular cysts03 medical and health sciences0302 clinical medicineBone DensityOsseointegrationLow densityAnimalscomputer-assisted image analysisIn vitro studyTibiaGeneral DentistryUNESCO:CIENCIAS MÉDICASInternal connectionDental ImplantsResearchTwist drillDental Implantation EndosseousResonance Frequency Analysis030206 dentistryResonance frequency analysisTorqueOtorhinolaryngologykeratocystsodontogenic cystsSurgeryImplantImplantologyBiomedical engineering
researchProduct