Search results for "Osseointegration"
showing 10 items of 130 documents
Osseointegration of miniscrews: a histomorphometric evaluation.
2007
SUMMARY Mini-implants and miniscrews are commonly used in orthodontics to provide additional temporary intraoral anchorage. Partial osseointegration represents a distinct advantage in orthodontic applications, allowing effective anchorage to be combined with easy insertion and removal. This article reports the histomorphometric fi ndings of the osseointegration of bracket screw bone anchors (BSBAs). In an experimental animal study, four BSBAs were inserted in the alveolar process of the lower jaw in each of fi ve male beagle dogs, aged 6.5 months from the same mother. Eleven screws were lost during the study, nine of them due to lack of primary stability. One screw was removed at the end of…
Primary loading of palatal implants for orthodontic anchorage--a pilot animal study.
2006
Summary Objectives This study aimed at evaluating the clinical performance and osseointegration of short orthodontic implants immediately loaded with orthodontic forces. Material and methods The investigation was designed as an experimental animal study. Eight palatal implants of the Ortho-system® were immediately loaded with 100 cN after palatal insertion in 4 female german shepherd dogs. Xylene orange and calcein green were used for polychrome sequential labelling. Histological preparation utilized the cutting and grinding technique. Outcome variables were clinical implant success, histological osseointegration and bone-to-implant contact rates. Results All (8/8) implants were clinically …
Thrombocytopenia-Absent Radius (TAR): Case report of dental implant and surgical treatment
2020
Thrombocytopenia-absent radius (TAR) syndrome is a congenital malformation in which affected individuals present reductions in the number of platelets, hypoplasia, or absence of radial bone unilaterally or bilaterally. Hematologic, skeletal, cardiac (particularly tetralogy of Fallot and septal-atrial defects), and gastrointestinal anomalies are most commonly associated with TAR syndrome. Skeletal changes result in a higher risk of dental and craniofacial trauma in patients with the syndrome. Thus, it is important for the dentist to be aware of the characteristics of TAR syndrome and its clinical management for better care of these patients. The objective of this study is to describe a case …
Ten-Year Retrospective Follow-Up Study of the TiOblast™ Dental Implant
2010
Purpose: Long-term results in the clinical outcome of different implant systems, including high patient numbers and a long follow-up time, are rare. This retrospective study evaluated the cumulative survival rate of a self-tapping, cylindrical implant system with a conical implant-abutment connection after 10 years of prosthetic loading. Materials and Methods: A total of 516 TiOblast™ implants (Astra Tech AB, Molndal, Sweden) were placed in 108 patients. The patients were treated in the Department of Oral and Maxillofacial Surgery, Johannes Gutenberg University, Mainz, Germany, between September 1994 and May 2005. The main indications for implantation were the treatment of edentulous mandib…
Implant failure and history of failed endodontic treatment: A retrospective case-control study
2017
Background Residual bacterial biofilm and/or bacteria in planktonic form may be survived in the bone following an extraction of an infected tooth that was endodontically treated unsuccessfully Failed endodontic treatment may be associated with failure of implants to osseointegrate in the same sites. Therefore, the aim of this retrospective case-control study is to examine the risk of implant failure in previous failed endodontic sites. Material and methods This retrospective case-control study is based on 94 dental records of implants placed at the University of Minnesota School of Dentistry. Dental records of patients who received an implant in sites with previously failed endodontic thera…
Modeling the electromechanical impedance technique for the assessment of dental implant stability
2015
We simulated the electromechanical impedance (EMI) technique to assess the stability of dental implants. The technique consists of bonding a piezoelectric transducer to the element to be monitored. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer's electrical admittance. As the structural vibrations depend on the mechanical impedance of the element, the measurement of the transducer's admittance can be exploited to assess the element's health. In the study presented in this paper, we created a 3D finite element model to mimic a transducer bonded to the abutment of a dental implant placed in a host bone site. We simulate…
Virtual simulation of an osseointegrated trans-humeral prosthesis: A falling scenario
2018
Abstract Introduction Traditional prosthetic solutions expose the amputee to numerous problems that limit his ability to safely perform the normal activities of daily life. In order to eliminate the problems related to the use of the traditional prosthesis with socket, a new technique was developed for fixing the prosthesis to the amputees based on the principle of osseointegration. The aim of this paper is to study and analyze the stress distribution on the interface between a trans-humeral osseointegrated prosthetic implant and the residual bone, identifying the most stressed areas and thus foreseeing possible failure phenomena of the entire prosthetic system and, after, to compare the st…
The importance of correct implants positioning and masticatory load direction on a fixed prosthesis
2018
Background Through the biomechanical study of dental implants, it is possible to understand the dissipation effects of masticatory loads in different situations and prevent the longevity of osseointegration. Aims: To evaluate the microstrains generated around external hexagon implants, using axial and non-axial loads in a fixed four-element prosthesis with straight implants and implants inclined at 17°. Material and Methods Three implants were modeled using CAD software following the manufacturer's measurements. Then, implants were duplicated and divided into two groups: one with straight implants and respective abutments, and the other with angled implants at 17° and respective abutments. …
Bone implant sockets made using three different procedures: a stability study in dogs
2012
Objective: This study compared the effects of three different methods of preparing bone implant sockets (drilling, osteotomes, and piezoelectric device) on osseointegration using resonance frequency analysis (RFA). Study Design: An experimental prospective study was designed. Material and Methods: Ten adult beagle dogs were studied. After 5 weeks, 23 out of 28 initially placed implants in the iliac crest were evaluated, comparing these three different procedures of bone implant socket. Student’s t-test (paired, two-tailed) was used to reveal differences among the three groups at each time point (SPSS 16.0, IL, USA). Results: After a 5-week healing period, the implants placed in sockets that…
Verlaufsbeobachtung des Kollagen- und Knochenstoffwechsels bei Patienten mit zementfreier Hüfttotalendoprothese*
2008
Introduction This study investigated the influence of concentration and activity of several markers of the collagen and bone metabolism and their impact on ingrowth of non-cemented total hip arthroplasty. Methods 40 patients underwent an implantation of a ABG-prosthesis. Before surgery and 1, 2, 12 and 24 weeks after it serum concentrations of PICP, ICTP, IGF-1, ON, b-AP, Calcium, Phosphate, GPT and Creatinin were measured and a collagen ratio (CQ) was calculated. Results PICP decreased until 1st week, increased at 2nd week and decreased again after that time. ICTP increased significantly in 1st week, reached a maximum in 2nd week and decreased after that. b-AP decreased in 1st week but inc…