Search results for "P wave"

showing 10 items of 32 documents

Space Charge Measurement under DC and DC Periodic Waveform

2018

In High Voltage systems, Partial Discharges (PDs) monitoring are one of the main diagnostic instrument to evaluate the reliability of the apparatus. Under Alternating Current (AC) stress, PDs detection and recognition techniques are well consolidated. On the contrary, the monitoring of PDs under Direct Current (DC) stress is difficult due to complexities related to the nature of the phenomenon, which cause the beginning of PDs events in proximity of the dielectric breakdown. This problem has been partially overcome by using a continuous Periodic waveform (DCP) with positive average value, as described in a recent published work. Under DC stress, another degradation factor is the Space Charg…

010302 applied physicsMaterials scienceDielectric strengthPEA methodElectronic Optical and Magnetic MaterialDirect currentHigh voltageDC stre01 natural sciencesSpace chargeSpace chargelaw.inventionComputational physicsStress (mechanics)Settore ING-IND/31 - ElettrotecnicaDCP strelawDCP waveform0103 physical sciencesWaveformElectrical and Electronic Engineering010306 general physicsAlternating currentVoltage
researchProduct

P and R Wave Detection in Complete Congenital Atrioventricular Block

2009

Complete atrioventricular block (type III AVB) is characterized by an absence of P wave transmission to ventricles. This implies that QRS complexes are generated in an autonomous way and are not coordinated with P waves. This work introduces a new algorithm for the detection of P waves for this type of pathology using non-invasive electrocardiographic surface leads. The proposed algorithm is divided into three stages. In the first stage, the R waves located by a QRS detector are used to generate the RR series and time references for the other stages of the algorithm. In the second stage, the ventricular activity (QT segment) is removed by using an adaptive filter that obtains an averaged pa…

AdultAdolescentBiomedical EngineeringYoung AdultQRS complexHeart Conduction SystemmedicineHumansSensitivity (control systems)Atrioventricular BlockChildMathematicsSeries (mathematics)P waveDetectorSignal Processing Computer-Assistedmedicine.diseaseAdaptive filterTransmission (telecommunications)Child PreschoolElectrocardiography AmbulatoryEnginyeria biomèdicaAtrioventricular blockAlgorithmAlgorithmsAnnals of Biomedical Engineering
researchProduct

Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers

2002

WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …

AdultMalemedicine.medical_specialtyTime FactorsAtrial sensingSensitivity and SpecificityPacemaker systemElectrocardiographyIntraoperative fluoroscopyInternal medicineHumansMulticenter Studies as TopicMedicineHeart Atriacardiovascular diseasesAgedRetrospective StudiesAged 80 and overbusiness.industryP waveCardiac Pacing ArtificialEquipment DesignGeneral MedicineMiddle AgedDipoleHeart Blockmedicine.anatomical_structureSingle leadAtrioventricular Nodecardiovascular systemCardiologyRight atriumEquipment FailureFemaleCardiology and Cardiovascular MedicinebusinessHolter monitoringFollow-Up StudiesPacing and Clinical Electrophysiology
researchProduct

Optogenetically blocking sharp wave ripple events in sleep does not interfere with the formation of stable spatial representation in the CA1 area of …

2016

During hippocampal sharp wave/ripple (SWR) events, previously occurring, sensory inputdriven neuronal firing patterns are replayed. Such replay is thought to be important for plasticity-related processes and consolidation of memory traces. It has previously been shown that the electrical stimulation-induced disruption of SWR events interferes with learning in rodents in different experimental paradigms. On the other hand, the cognitive map theory posits that the plastic changes of the firing of hippocampal place cells constitute the electrophysiological counterpart of the spatial learning, observable at the behavioral level. Therefore, we tested whether intact SWR events occurring during th…

LightPhysiologylcsh:MedicineHippocampusTetrodesMiceAnimal Cells571 PhysiologyMedicine and Health Scienceslcsh:ScienceNeuronsLight PulsesBrain MappingNeuronal PlasticityPyramidal CellsPhysicsElectromagnetic RadiationBrainLaboratory EquipmentSignal Filteringsharp wave ripple eventesBioassays and Physiological AnalysisOptical EquipmentVacuum ApparatusPhysical SciencesEngineering and TechnologyFemaleCellular TypesAnatomyResearch ArticleGanglion CellsArchaeal ProteinsSpatial LearningEquipmentResearch and Analysis Methodsuni (lepotila)AnimalshippokampusCA1 Region HippocampalLaserslcsh:RCorrectionBiology and Life SciencesNeurophysiological AnalysisCell BiologyBrain WavesMice Inbred C57BLOptogeneticsCellular NeuroscienceSignal ProcessingExploratory Behavior570 Life sciences; biologylcsh:QPhysiological ProcessesSleepNeuroscience
researchProduct

European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead

2002

Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of…

MaleBradycardiaTachycardiaPacemaker Artificialmedicine.medical_specialtyDefibrillationHeart Ventriclesmedicine.medical_treatmentImplantable defibrillatorElectrocardiographyInternal medicineTachycardia SupraventricularmedicineHumansHeart AtriaProspective Studiescardiovascular diseasesLead (electronics)AgedEjection fractionbusiness.industryP waveGeneral MedicineMiddle AgedDefibrillators ImplantableElectrodes ImplantedEuropemedicine.anatomical_structureVentricleVentricular Fibrillationcardiovascular systemCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessPacing and Clinical Electrophysiology
researchProduct

Extreme Pulsus Alternans with P Wave Alternans in a Child

2002

Pulsus alternans was observed in a child with left ventricular dysfunction secondary to systemic hypertension. The Echo-Doppler of supravalvular aorta and a simultaneous electrocardiographic trace (ECG) clearly demonstrated the mechanism of an apparent abrupt halving of pulse frequency compared with the ECG, similar to an electromechanical dissociation 2: 1. Besides the extreme pulsus alternans, a P wave and a PP cycle length change were also observed. Both mechanical and electrical alternans disappeared with afterload reduction by nitroprusside treatment.

MaleNitroprussidemedicine.medical_specialtyElectrical alternansVentricular Dysfunction LeftElectrocardiographyDoppler EchocardiographyAfterloadmedicine.arteryInternal medicinePulse frequencyHumansMedicinecardiovascular diseasesCardiac OutputChildPulseCycle lengthAntihypertensive AgentsAortabusiness.industryP waveEchocardiography DopplerPulsus alternansAnesthesiaHypertensionPediatrics Perinatology and Child Healthcardiovascular systemCardiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessPediatric Cardiology
researchProduct

A useful muscarinic parameter and the differential recording of atrial and ventricular tension in the perfused rabbit heart

1971

1. A simple method of recording right atrial tension from the Langendorff perfused rabbit has been described; it is based on the “transverse” method of recording cardiac contractions described by Beckett (1970). 2. Right atrial and ventricular tensions were recorded by transducers attached to threads stitched into the right atrium and right ventricle, the heart being retained and prevented from rotating by two threads stitched into the intraventricular septum as described by Beckett. 3. Right ventricular diastolic tension was adjusted to 7.5 g. Interference with the atrial record by ventricular systole was overcome by adjustment of diastolic right atrial tension to its optimal value between…

Malemedicine.medical_specialtyHeart VentriclesTransducersDiastoleBlood PressureHeart RateInternal medicineMuscarinic acetylcholine receptormedicineAnimalsVentricular FunctionHeart Atriacardiovascular diseasesSympathomimeticsPharmacologyCardiac cyclebusiness.industryP waveHeartVagus NerveGeneral MedicineAtrial FunctionStimulation ChemicalCardiovascular physiologyGanglionPerfusionmedicine.anatomical_structureParasympathomimeticsVentricleMuscle TonusAnesthesiacardiovascular systemCardiologyFemaleRabbitsbusinessPerfusionMuscle ContractionNaunyn-Schmiedebergs Archiv f�r Pharmakologie
researchProduct

Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.

1998

Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…

Malemedicine.medical_specialtyPacemaker ArtificialTime FactorsParoxysmal atrial fibrillationVentricular stimulationInternal medicineAtrial FibrillationMedicineHumansSinus rhythmIn patientcardiovascular diseasesbusiness.industryP waveCardiac Pacing ArtificialAtrial fibrillationGeneral MedicineMiddle Agedmedicine.diseaseHeart BlockSingle leadAnesthesiacardiovascular systemCardiologyMode switchingFemaleCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesPacing and clinical electrophysiology : PACE
researchProduct

How Can We Identify the Best Implantation Site for an ECG Event Recorder?

2000

ZELLERHOFF, C., et al.: How Can We Identify the Best Implantation Site for an ECG Event Recorder? The aim of this study was to show how to find the preferable implantation site for an ECG event recorder (ECG-ER). We compared the quality of bipolar ECG recordings (4-cm electrode distance, vertical position) in 65 patients at the following sites: left and right subclavicular, left and right anterior axillary line (4th-5th interspace), left and right of the sternum (4th-5th interspace), heart apex, and subxyphoidal. The results were compared to the standard ECG lead II. In 30 patients, an additional comparison between vertical and horizontal ECG registrations was done using the same sites. ECG…

Malemedicine.medical_specialtySternumbusiness.industryP waveImplantation SiteAxillary linesGeneral MedicineMiddle AgedQT intervalElectrodes ImplantedProsthesis ImplantationElectrocardiographyQRS complexInternal medicineHorizontal position representationCardiologymedicineHumansFemalecardiovascular diseasesCardiology and Cardiovascular MedicinebusinessStandard ECGPacing and Clinical Electrophysiology
researchProduct

The Partial Discharge Behavior of Different Materials under DC Periodic Stress

2019

The aim of the present work is to evaluate the PDs behavior by stressing a specimen with a new type of waveform named DCP. This waveform was proposed by the authors in a previous work with the aim to overcome the main issues of PDs under DC stress. In the previous work PDs test on Kapton specimen was performed. In this paper, we propose a new DCP test on a different insulating material, such as the XLPE. The obtained patterns and the acquired data have been evaluated in order to validate the DCP approach as a new method for PDs measure under constant stress. The behavior of the XLPE material has been reported and compared with the former measures obtained for Kapton material.

Materials scienceDC streKaptonStress (mechanics)Settore ING-IND/31 - ElettrotecnicaDielectric measurementConstant stressDCP waveformPartial dischargeWaveformPDComposite materialPartial DischargeXLPE material
researchProduct