Search results for "PASS"

showing 10 items of 1629 documents

Die passivischen Ausdrücke der medizinischen Fachsprache

1998

PassivPassivparaphrasenFachsprachen
researchProduct

Growth of passive layers on nickel during their voltammetric anodic dissolution in a weakly acid medium

2006

Abstract Quartz crystal microbalance in combination with voltammetry has been used for studying the electrochemical oxidation behaviour of a nickel deposit in a weakly acid medium. The instantaneous mass/charge ratio (Fdm/dQ) analysis allows to obtain the fraction of charge consumed in the passivation process, and, that way, the experimental kinetic equation of the passive layer growth. This experimental law has been fitted to the theoretical equation derived from the point defect model theory under voltammetric conditions.

PassivationChemistryGeneral Chemical EngineeringInorganic chemistryAnalytical chemistrychemistry.chemical_elementCharge (physics)Quartz crystal microbalanceElectrochemistryNickelElectrochemistryAnodic dissolutionLayer (electronics)VoltammetryElectrochimica Acta
researchProduct

Characteristic Excitation Wavelength Dependence of Fluorescence Emissions in Carbon "quantum" Dots

2017

Carbon "quantum" dots (CDots), generally defined as small carbon nanoparticles with various surface passivation schemes, have emerged to represent a rapidly advancing and expanding research field. CDots are known for their bright and colorful fluorescence emissions, where the colorfulness is associated with the emissions being excitation wavelength dependent. In this work, CDots with 2,2′-(ethylenedioxy)bis(ethylamine) (EDA) for surface functionalization were studied systematically by using steady-state and time-resolved fluorescence methods. The observed fluorescence quantum yields are strongly excitation wavelength dependent, and the dependence apparently tracks closely the observed absor…

PassivationField (physics)Carbon Nanoparticleschemistry.chemical_element02 engineering and technology010402 general chemistry01 natural sciencesPhysical and Theoretical ChemistryQuantumExcitation wavelengthbusiness.industryElectronic Optical and Magnetic MaterialSettore FIS/01 - Fisica Sperimentale021001 nanoscience & nanotechnologyFluorescence0104 chemical sciencesElectronic Optical and Magnetic MaterialsSurfaces Coatings and FilmsGeneral EnergyEnergy (all)chemistryCarbon quantum dotsOptoelectronicsAtomic physics0210 nano-technologybusinessCarbon
researchProduct

Surface passivation of gallium selenide by nitrogen implantation

2002

In this paper we report on the characterization of nitrogen-implanted single-crystal GaSe samples. Nitrogen atoms were implanted at 80 keV, with doses ranging from 4 × 10 13 to 10 15 N + ions cm -2 . Next, samples were aged in open air and characterized by small-area XPS, together with an unimplanted clean surface, in order to quantify the effects of the nitrogen implantation. In general, we found that the oxidation was fully prevented in N + -implanted samples.

PassivationGallium selenideInorganic chemistrychemistry.chemical_elementSurfaces and InterfacesGeneral ChemistryCondensed Matter PhysicsNitrogenSurfaces Coatings and FilmsIonIon implantationchemistryX-ray photoelectron spectroscopyMaterials ChemistrySurface structureOpen airSurface and Interface Analysis
researchProduct

Chloride role in the surface of nickel electrode

1998

The chloride ion participation in the dissolution process on nickel electrodes in acid media as well as in the formation of the passive layer and in the pitting corrosion induction were studied. Composite electrodes containing nickel powder dispersed in a polymeric matrix show similar processes to those observed in polycrystalline nickel. Furthermore, phenformine hydrochloride inhibits the dissolution process due to the adsorption of the organic cation on the metal surface, although it does not protect the metal from pitting corrosion. Electrochemical impedance spectroscopy data allowed us to propose a physical model for the role of chloride ion in the dissolution and passivation processes …

PassivationGeneral Chemical EngineeringInorganic chemistrychemistry.chemical_elementChlorideDielectric spectroscopyCorrosion inhibitorchemistry.chemical_compoundNickelAdsorptionchemistryElectrochemistrymedicinePitting corrosionDissolutionmedicine.drugElectrochimica Acta
researchProduct

Zerstörungsfreie Phasenanalyse dünner Oberflächenschichten mittels Konversionselektronen

1987

By use of an appropriate gamma radiation, conversion electrons may be produced by Mossbauer effect also in a depth below the sample surface deeper than the free path for inelastic electron scattering. Because the Mossbauer spectrum of the conversion electrons reflects the local phase composition, the recording of all electrons escaping from the surface allows an integral phase analysis of a layer of some 10–100 nm thickness. If only electrons within a narrow range of energy are recorded, a depth selective phase analysis is possible. The applicability of these two techniques of conversion electron spectroscopy is demonstrated by a few examples concerning oxidation and passivation of steel. C…

PassivationMössbauer effectChemistryClinical BiochemistryAnalytical chemistryGeneral MedicineElectronRadiationElectron spectroscopyAnalytical ChemistryMössbauer spectroscopyInelastic electron scatteringGeneral Materials ScienceAtomic physicsLayer (electronics)Fresenius' Zeitschrift für analytische Chemie
researchProduct

Determination of time dependence of passive layer on nickel from instantaneous mass/charge function F(dm/dQ) in competitive passivation/dissolution c…

2006

Nickel metal deposited on gold electrodes was studied in the passivity range of potentials under potentiostatic conditions and in a weakly acid sulphate medium. Mass and current variations during electrochemical experiments were analysed with the help of the instantaneous mass/charge ratio (Fdm/dQ). This analysis allows to obtain the intensity current component associated to the formation of a passive layer of Ni(OH)2, and, in this way, the experimental thickness growth. These experimental findings have been fitted to a theoretical model based on the point defect model theory for obtaining the time dependence of the thickness of the passive layer during the first stages of growth of the pas…

PassivationPassivityInorganic chemistryAnalytical chemistrychemistry.chemical_elementlcsh:ChemistryMetalNickellcsh:Industrial electrochemistrylcsh:QD1-999chemistryvisual_artElectrodeElectrochemistryvisual_art.visual_art_mediumSurface layerCyclic voltammetryDissolutionlcsh:TP250-261Electrochemistry Communications
researchProduct

Air movement representation as a tool for urban and architectural environmental quality

2017

Air movement is a measurable physical phenomenon that produces indirectly measurable effects on people and on the environment. It is an essential prerequisite for the comfort and the hygiene of the built environment and it is highly relevant to the passive cooling strategies. The relationships between air movement and built environment have to be analysed under a multi-scale vision. They fall within the field of urban and architectural design because they can be influenced by artificial expedients, although they are always caused by natural factors. This paper discusses the need for a complete and objective representation of different kinds of air movement, to improve the urban and architec…

Passive coolingAir Movement.Environmental DesignBioclimatic ArchitectureSettore ICAR/12 - Tecnologia Dell'Architettura
researchProduct

A Proposed Methodology to Control Body Temperature in Patients at Risk of Hypothermia by means of Active Rewarming Systems

2014

Hypothermia is a common complication in patients undergoing surgery under general anesthesia. It has been noted that, during the first hour of surgery, the patient’s internal temperature (Tcore) decreases by 0.5–1.5°C due to the vasodilatory effect of anesthetic gases, which affect the body’s thermoregulatory system by inhibiting vasoconstriction. Thus a continuous check on patient temperature must be carried out. The currently most used methods to avoid hypothermia are based on passive systems (such as blankets reducing body heat loss) and on active ones (thermal blankets, electric or hot-water mattresses, forced hot air, warming lamps, etc.). Within a broader research upon the environment…

Passive systemsmedicine.medical_specialtyArticle SubjectOperating theatresipotermia; temperatura corporea; sale operatorie; Anesthesialcsh:MedicineHypothermiaBlanketAnesthesia GeneralGeneral Biochemistry Genetics and Molecular BiologyBody Temperatureipotermiasale operatoriemedicineHumansIn patienttemperatura corporeaAnesthesiaRewarmingSettore ING-IND/11 - Fisica Tecnica AmbientaleGeneral Immunology and Microbiologybusiness.industrylcsh:RHeat lossesBedding and LinensGeneral MedicineHypothermiaHeat stressSurgeryVasoconstrictionAnesthesiaHypothermia Heat Stress Warming Blanket Thermal Comfort Skin Temperature Body Temperature Core Temperaturemedicine.symptombusinessWarming blanketBody Temperature RegulationResearch Article
researchProduct

Passive Transport of Ionic Drugs through Membranes with pH-Dependent Fixed Charges

2001

We have studied both theoretically and experimentally the passive transport of ionic drugs through membranes with pH-dependent fixed charge. The system considered constitutes a simplified model for pH-controlled drug delivery through membranes of biochemical and pharmaceutical interest. The theoretical approach employed is based on the Nernst-Planck flux equations and all of the species present in the system (the neutral or ionic drug and the hydrogen and hydroxide ions) have been taken into account together with a Langmuir-type isotherm for the adsorption of the ionic drug onto the membrane surface. The membrane permeabilities of cationic, anionic, and neutral drugs through porous membrane…

Passive transportChemistryIonic bondingPolyelectrolyteSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsIonBiomaterialschemistry.chemical_compoundColloid and Surface ChemistryAdsorptionMembraneChemical engineeringPolymer chemistryHydroxideDrug carrierJournal of Colloid and Interface Science
researchProduct