Search results for "PHOTOMULTIPLIER"

showing 10 items of 194 documents

NEXT-100 Technical Design Report (TDR). Executive summary

2012

[EN] In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ßß0v) in 136XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout pla…

MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURASPhotomultiplierPhysics - Instrumentation and DetectorsBar (music)Time projection chambersFOS: Physical scienceschemistry.chemical_elementWavelength shifterTracking (particle physics)7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)chemistry.chemical_compoundXenonOptics0103 physical sciences010306 general physicsInstrumentationMathematical PhysicsPhysicsTime projection chamber010308 nuclear & particles physicsbusiness.industryDetectorFísicaTetraphenyl butadieneDetectorsInstrumentation and Detectors (physics.ins-det)Gas detectorsDetectors de gasoschemistryDetector design and construction technologies and materialsbusinessJournal of Instrumentation
researchProduct

Design and realization of a portable multichannel continuous wave fNIRS

2014

A design and implementation of a portable functional Near InfraRed Spectroscopy embedded system prototype is described. In this theoretical and experimental work, we present an embedded system hosting 64 LED sources and 128 Silicon PhotoMultiplier detectors (SiPM). The elementary part of the structure is a flexible probe “leaf” consisting of 16 SiPMs, 4 couples of LEDs, each operating at two wavelengths, and a temperature sensor. The hardware system is based on an ARM main microcontroller that allows to perform both the switching time of LEDs and the acquisition of the SiPM outputs. The performed preliminary experimental tests achieved very promising results, thus demonstrating the effectiv…

Materials scienceDetectorSettore ING-INF/02 - Campi ElettromagneticiSettore ING-INF/01 - ElettronicaSilicon PhotoMultiplierlaw.inventionSwitching timeembedded systemMicrocontrollerSilicon photomultiplierlawElectronic engineeringFunctional Near Infrared SpectroscopyFunctional near-infrared spectroscopyContinuous wavephotodetectorRealization (systems)Light-emitting diode2014 AEIT Annual Conference - From Research to Industry: The Need for a More Effective Technology Transfer (AEIT)
researchProduct

ECRIS plasma spectroscopy with a high resolution spectrometer

2020

Electron Cyclotron Resonance Ion Source (ECRIS) plasmas contain high-energy electrons and highly charged ions implying that only noninvasive methods such as optical emission spectroscopy are reliable in their characterization. A high-resolution spectrometer (10 pm FWHM at 632 nm) enabling the detection of weak emission lines has been developed at University of Jyväskylä, Department of Physics (JYFL) for this purpose. Diagnostics results probing the densities of ions, neutral atoms, and the temperature of the cold electron population in the JYFL 14 GHz ECRIS are described. For example, it has been observed that the cold electron temperature drops from 40 eV to 20 eV when the extraction volta…

Materials scienceIon beamspektroskopiaelectron impact ionizationphotomultipliers01 natural sciences7. Clean energyElectron cyclotron resonance010305 fluids & plasmasIonion sourcesPhysics::Plasma Physics0103 physical sciencesEmission spectrumInstrumentation010302 applied physicsplasma confinementamplitude modulationPlasmaIon sourceemission spectroscopymonochromatorsdoppler effectElectron temperatureAtomic physicsDoppler broadeningplasma spectroscopy
researchProduct

A Design of Scintillator Tiles Read Out by Surface-Mounted SiPMs for a Future Hadron Calorimeter

2015

Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles…

Materials sciencePhotonPhysics - Instrumentation and Detectorsbusiness.industryDynamic rangePhysics::Instrumentation and DetectorsFOS: Physical sciencesCosmic rayInstrumentation and Detectors (physics.ins-det)ScintillatorOpticsSilicon photomultiplierSampling (signal processing)visual_artvisual_art.visual_art_mediumTilePhotonicsDetectors and Experimental Techniquesbusinessphysics.ins-det
researchProduct

SiPMs coated with TPB: coating protocol and characterization for NEXT

2012

[EN] Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless \bb decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifte…

Materials sciencePhysics - Instrumentation and DetectorsFOS: Physical scienceschemistry.chemical_elementengineering.materialWavelength shifterTracking (particle physics)7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)XenonSilicon photomultiplierCoating0103 physical sciencesSensitivity (control systems)Visible and IR photons (solid-state)010306 general physicsInstrumentationPhoton detectors for UVMathematical PhysicsScintillationTime projection chamber010308 nuclear & particles physicsbusiness.industryTime projection Chambers (TPC)FísicaDetectorsInstrumentation and Detectors (physics.ins-det)Gas detectorsScintillators scintillation and light emission processes (solid gas and liquid scintillators)Detectors de gasoschemistryParticle tracking detectors (Solid-state detectors)engineeringOptoelectronicsbusiness
researchProduct

Development of Structured Scintillator Tiles for High-Granularity Calorimeters

2020

Calorimeters with a fine 3-D segmentation are considered to be a very promising technology for future high-energy physics experiments, since they provide in combination with particle flow algorithms excellent jet energy resolution and particle identification capabilities. Depending on the size, millions of individual channels consisting of a photosensor coupled to a scintillator tile have to be assembled. The usage of structured plastic scintillators with optically separated segments simplifies the mass production. We present the design, production, and performance of a 36 cm × 36 cm scintillator tile divided into 144 segments matching the geometry of the SiPM-based calorimeter frontend dev…

Materials sciencePhysics::Instrumentation and Detectorsbusiness.industryPhotodetectorScintillatorParticle identificationCalorimeterSilicon photomultiplierOpticsvisual_artvisual_art.visual_art_mediumElectronicsGranularityTilebusiness2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

PPG embedded system for blood pressure monitoring

2014

In this work, we have designed and implemented a microcontroller-based embedded system for blood pressure monitoring through a PhotoPlethysmoGraphic (PPG) technique. In our system, it is possible to perform PPG measurements via reflectance mode. Hardware novelty of our system consists in the adoption of Silicon PhotoMultiplier detectors. The signal received from the photodetector is used to calculate the instantaneous heart rate and therefore the heart rate variability. The obtained results show that, by using our system, it is possible to easily extract both the PPG and the breath signal. These signals can be used to monitor the patients during the convalescence both in hospital and at hom…

Materials scienceSettore INF/01 - InformaticaPhotoPlethysmoGraphybusiness.industryDetectorPhotodetectorSettore ING-INF/02 - Campi ElettromagneticiSignalReflectivitySilicon PhotoMultiplierembedded systemMicrocontrollerSilicon photomultipliersensorEmbedded systemHeart rate variabilityBlood pressure monitoringsense organsbusinessComputer hardware2014 AEIT Annual Conference - From Research to Industry: The Need for a More Effective Technology Transfer (AEIT)
researchProduct

Characterization of SiPM properties at liquid nitrogen temperature

2016

SiPM operation at cryogenic temperatures fails for many common devices. A particular type with deep channels in the silicon substrate instead of quenching resistors was thoroughly characterized from room temperature down to liquid nitrogen temperature by illuminating it with low light levels. The devices were mounted in vacuum with the temperature stabilized to allow long-term operation. SiPM signals from a LED pulser were acquired with single-pixel resolution. Generalized fits to the charge collection spectra were used to extract properties like single-pixel gain, inter-pixel variation, breakdown voltage, and photon detection efficiency. With these measurements a deeper investigation of th…

Materials scienceSiliconPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industrychemistry.chemical_elementCryogenicsLiquid nitrogen01 natural sciencesSpectral linelaw.inventionSilicon photomultiplierchemistrylaw0103 physical sciencesOptoelectronicsBreakdown voltagePhotonicsResistorbusiness2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
researchProduct

Performance of sensl C-Series SiPM with high photoelectron resolution at cryogenic temperatures

2016

The C-Series of silicon photomultipliers (SiPM) from SensL provides devices with a fast response and high performance at low cost. The device's ability to detect light at temperatures of liquid nitrogen (77K) and liquid helium (4 K) with high photoelectron resolution was demonstrated. Results include relative photon detection efficiency (PDE), gain, microcell capacitance, and cross-talk probability at different over-voltages, both at room and at cryogenic temperatures. At 77K the SiPM demonstrated significantly improved operating characteristics while at 4K the observed increase in break-down voltage, the reduction of PDE by a factor of 2-3, and the extensively dropped microcell capacitance…

Materials sciencebusiness.industryLiquid heliumchemistry.chemical_elementLiquid nitrogenCapacitancelaw.inventionSilicon photomultiplierchemistrylawElectronic engineeringOptoelectronicsMicrocellPhotonicsbusinessHeliumVoltage2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
researchProduct

Signal to Noise Ratio of Silicon Photomultipliers measured in the Continuous Wave Regime

2014

We performed a Signal to Noise Ratio characterization, in the continuous wave regime, at different bias voltages, frequencies and temperatures, on a novel class of silicon photomultipliers fabricated in planar technology on silicon p-type substrate. Signal to Noise Ratio has been measured as the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square deviation of the overall current flowing to the device. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current. We have also performed a comparison between our SiPMs and a photomultiplier tube in terms of Signal to Noise Ratio, as a function …

Noise temperatureMaterials sciencePhysics::Instrumentation and Detectorsbusiness.industryphotomultipliers sipm snr detector siliconNoise spectral densityElectrical engineeringShot noiseSettore ING-INF/02 - Campi ElettromagneticiNoise figureNoise (electronics)Settore ING-INF/01 - ElettronicaSignal-to-noise ratioOpticsNoise generatorFlicker noisebusiness
researchProduct